Immersion & wet locations
Water-blocked core matrix and hydrolysis-resistant subsea jacketing withstand continuous deepwater hydrostatic pressure.
Product
Wet-Mate Individually Foil-Screened Twisted Triples & Screened Pair/Multicore Hybrid Underwater PUR Sensor Cable (P3TST20# & P1TSP20/5C20#) (Doc. 2020052SC Wet-Mate, 600 V, -30 °C to +80 °C, min. bend radius 8 × OD).
Typical values for this cable type, based on Subsea Doc. 2020052SC & 2014039SC (IR ≥ 50 GΩ/kft) Sensor — confirmed in the datasheet and quotation for your order.
Application fit
Wet-Mate Individually Foil-Screened Twisted Triples & Screened Pair/Multicore Hybrid Underwater PUR Sensor Cable (P3TST20# & P1TSP20/5C20#) (Doc. 2020052SC Wet-Mate, 600 V, -30 °C to +80 °C, min. bend radius 8 × OD).
Water-blocked core matrix and hydrolysis-resistant subsea jacketing withstand continuous deepwater hydrostatic pressure.
Torque-balanced aramid or contra-helical steel armour supports vertical winch deployment without hockling.
Marine-grade outer sheath and armour package resist LARS sheave abrasion, UV exposure and salt-spray corrosion.
High tensile breaking strength supports underwater towing, ROV excursion and seabed plough/trencher duty.
Subsea umbilical and tow construction is not intended for high-cycle indoor factory drag chains.
Use Drag-Chain Servo CableConstruction
Shown: P3TST20# / P1TSP20/5C20# (Subsea Doc. 2020052SC & 2014039SC (IR ≥ 50 GΩ/kft) Sensor) featuring screened twisted triples (3×3×20 awg), triple color coding and overall binder & black pur jacket (4-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | Screened Twisted Triples (3×3×20 AWG) | Nine 0.52 mm² (19/32 AWG) tinned copper conductors with ≥50 GΩ/kft PP insulation |
| 2 | Triple Color Coding | Triple 1: Black/White/Red · Triple 2: Green/Orange/Blue · Triple 3: Wh-Bk/Rd-Bk/Gn-Bk |
| 3 | Individual Foil Screen & Drain (3×) | Aluminium/Polyester shield (foil in) + 20 AWG tinned Cu drain + clear polyester tape |
| 4 | Overall Binder & Black PUR Jacket | Roundness fillers + clear polyester tape + 1.03 mm black halogen-free PUR (Ø 10.41 mm) |
Built to Subsea Doc. 2020052SC & 2014039SC (IR ≥ 50 GΩ/kft) Sensor with screened twisted triples (3×3×20 awg) and overall binder & black pur jacket
Available in custom continuous subsea/wellbore drum lengths or pre-terminated assemblies
Supplied with EN 10204 3.1 routine dielectric, resistance & pressure/dimensional report
Technical data
Sizes
Manufactured to Subsea Doc. 2020052SC & 2014039SC (IR ≥ 50 GΩ/kft) Sensor for subsea, offshore, deep-well and marine applications.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Tensile rating kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| P3TST20# / P1TSP20/5C20# Construction Schedule (−30…+80 °C) | |||||||
| P3TST20# Config A (Compact) | 4×2×24 AWG + 2×18 AWG (or 4C) | Stranded tinned Cu (IEC 60228 / ASTM) | 10.4 | 155 | 4.5 | 85 | |
| P3TST20# Config B (Standard) | 4×2×20 AWG + 4×16 AWG (or 8C) | Stranded tinned Cu (IEC 60228 / ASTM) | 13.3 | 265 | 9.6 | 110 | |
| P3TST20# Config C (Heavy Hybrid) | 8×2×20 AWG + 4×12 AWG (or 12C) | Stranded tinned Cu (IEC 60228 / ASTM) | 16.6 | 420 | 18.5 | 140 | |
| Configuration | Max. DC R₂₀ / Atten. Ω/km or dB/km | Rating / Impedance | Operating temp. |
|---|---|---|---|
| 4×2×24 AWG + 2×18 AWG (or 4C) | 28.40 | 600 V (45–100 Ω data) | −30…+80 °C |
| 4×2×20 AWG + 4×16 AWG (or 8C) | 10.70 | 600 V (45–100 Ω data) | −30…+80 °C |
| 8×2×20 AWG + 4×12 AWG (or 12C) | 5.40 | 600 V (High-Power Hybrid) | −30…+80 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance, continuity & dimensional verification (Subsea Doc. 2020052SC & 2014039SC (IR ≥ 50 GΩ/kft) Sensor) | DC resistance at 20 °C / optical attenuation and outer diameter within Subsea Doc. 2020052SC & 2014039SC (IR ≥ 50 GΩ/kft) Sensor tolerances | Every manufactured drum length |
| High-voltage dielectric & insulation resistance test (Subsea Doc. 2020052SC & 2014039SC (IR ≥ 50 GΩ/kft) Sensor) | Zero dielectric breakdown and verified insulation resistance for 600 V rating | Every manufactured drum length |
| Sample tests | ||
| Hydrostatic pressure, water-blocking & mechanical endurance qualification (Subsea Doc. 2020052SC & 2014039SC (IR ≥ 50 GΩ/kft) Sensor) | Verified submersion integrity, tensile load and thermal stability across −30…+80 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.