Quayside shore-to-ship HVSC connection
Flexible Class 5 copper and double elastomeric sheath handle quayside shore-to-ship power jumper deployment.
Product
(N)SHÖU-J & (N)SHÖU-O 0.6/1 kV (Reeling (MT) / DIN VDE 0250-812) Class 5 3GI3 EPR-Insulated GM1b/5GM3 Double-Sheathed Heavy-Duty Low-Voltage Shore-to-Ship & Deck Winch Rubber Cable (DIN VDE 0250-812, 0.6/1 kV, -40 to +90 °C).
Typical values for this cable type, based on DIN VDE 0250-812 / IEC 60228 Class 5 — confirmed in the datasheet and quotation for your order.
Application fit
(N)SHÖU-J & (N)SHÖU-O 0.6/1 kV (Reeling (MT) / DIN VDE 0250-812) Class 5 3GI3 EPR-Insulated GM1b/5GM3 Double-Sheathed Heavy-Duty Low-Voltage Shore-to-Ship & Deck Winch Rubber Cable (DIN VDE 0250-812, 0.6/1 kV, -40 to +90 °C).
Flexible Class 5 copper and double elastomeric sheath handle quayside shore-to-ship power jumper deployment.
5GM3/5GM5 polychloroprene or SHF2-MUD rubber jacket resists drilling muds, hydraulic oils, impact and deck abrasion.
Pressure-tight elastomeric bedding and outer sheath support continuous wet-deck and submersible marine operation.
High mechanical tear resistance and cold flexibility down to −40 °C suit mobile deck machinery and portable skids.
Heavy marine rubber cable is not designed for high-acceleration automation drag chains.
Use Drag-Chain Control CableConstruction
Shown: (N)SHOU-J & (N)SHOU-O 0.6/1 KV (VDE 0250-812) (DIN VDE 0250-812 / IEC 60228 Class 5) featuring class 5 flexible copper (5g25 mm²), 3gi3 90 °c epr core insulation and 5gm3 / 5gm5 heavy polychloroprene jacket (4-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | Class 5 Flexible Copper (5G25 mm²) | DIN VDE 0295 Class 5 finely stranded copper conductors |
| 2 | 3GI3 90 °C EPR Core Insulation | VDE 0207 Teil 20 3GI3 ethylene-propylene rubber insulation |
| 3 | GM1b Elastomeric Inner Sheath | Pressure-tight extruded EPR inner bedding sheath (up to 500 m water depth) |
| 4 | 5GM3 / 5GM5 Heavy Polychloroprene Jacket | High-visibility yellow oil-, seawater- and tear-resistant rubber sheath |
Built to DIN VDE 0250-812 / IEC 60228 Class 5 with class 5 flexible copper (5g25 mm²) and 5gm3 / 5gm5 heavy polychloroprene jacket
Available in custom continuous shipboard/offshore drum lengths or with marine EMC cable glands
Supplied with EN 10204 3.1 routine dielectric, conductor resistance & flame/fire test report
Technical data
Sizes
Manufactured to DIN VDE 0250-812 / IEC 60228 Class 5 for shipboard, offshore platform, drilling rig and marine applications.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Tensile rating kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| (N)SHOU-J & (N)SHOU-O 0.6/1 KV (VDE 0250-812) Construction Schedule (−40…+90 °C) | |||||||
| (N)SHOU-J 3×16+1G16 mm² | 3 × 16 + 1G16 mm² (4G16) | IEC 60228 Class 2/5 Cu/SnCu | 22.4 | 920 | 3.8 | 135 | |
| (N)SHOU-J 3×35+1G16 mm² | 3 × 35 + 1G16 mm² (4G35) | IEC 60228 Class 2/5 Cu/SnCu | 28.8 | 1,690 | 7.4 | 175 | |
| (N)SHOU-J 3×70+1G35 mm² | 3 × 70 + 1G35 mm² (4G70) | IEC 60228 Class 2/5 Cu/SnCu | 38.2 | 3,260 | 14.8 | 230 | |
| Configuration | Max. DC R₂₀ / Atten. Ω/km or dB/km | Rating / Impedance | Operating temp. |
|---|---|---|---|
| 3 × 16 + 1G16 mm² (4G16) | 1.15 | 0.6/1 kV (98 A) | −40…+90 °C |
| 3 × 35 + 1G16 mm² (4G35) | 0.52 | 0.6/1 kV (158 A) | −40…+90 °C |
| 3 × 70 + 1G35 mm² (4G70) | 0.27 | 0.6/1 kV (245 A) | −40…+90 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance, continuity & dimensional verification (DIN VDE 0250-812 / IEC 60228 Class 5) | DC resistance at 20 °C / optical attenuation and outer diameter within DIN VDE 0250-812 / IEC 60228 Class 5 tolerances | Every manufactured drum length |
| High-voltage dielectric & insulation resistance test (DIN VDE 0250-812 / IEC 60228 Class 5) | Zero dielectric breakdown and verified insulation resistance for 0.6/1 kV rating | Every manufactured drum length |
| Sample tests | ||
| Flame, fire integrity, oil/mud & mechanical qualification (DIN VDE 0250-812 / IEC 60228 Class 5) | Verified flame/fire performance, fluid resistance and thermal stability across −40…+90 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.