Fixed installation
Individually foil-shielded pairs plus overall tinned copper braid (S/FTP) ensure 1000 MHz 10GbE and fieldbus EMC immunity.
Product
LKSM-CAT7 S/FTP & LKSM-PROFIBUS / CAN-Bus Shipboard 10GbE Ethernet & Fieldbus Cable (IEC 61156-5 / IEC 60092-376) engineered for 125/250 V service across -40 to +85 °C (min. bend radius 8 × OD).
Typical values for this cable type, based on IEC 61156-5/6 Cat. 7 (1000 MHz) & IEC 60092-376 / DNV-LR-ABS Approved — confirmed in the datasheet and quotation for your order.
Application fit
LKSM-CAT7 S/FTP & LKSM-PROFIBUS / CAN-Bus Shipboard 10GbE Ethernet & Fieldbus Cable (IEC 61156-5 / IEC 60092-376) engineered for 125/250 V service across -40 to +85 °C (min. bend radius 8 × OD).
Individually foil-shielded pairs plus overall tinned copper braid (S/FTP) ensure 1000 MHz 10GbE and fieldbus EMC immunity.
Stranded tinned/bare copper conductors withstand continuous hull vibration and terminate cleanly into marine RJ45/M12 connectors.
Halogen-free SHF1 and oil/mud-resistant SHF2 jackets meet DNV, ABS, LR and IEC 60092-376 marine standards.
Controlled 100 Ω / 120 Ω / 150 Ω characteristic impedance supports long-distance PLC, propulsion and sensor buses.
Fixed shipboard data and fieldbus cable is not intended for high-tension motorized reeling drums.
Use HVSC Shore Power Reeling CableConstruction
Shown: LKSM-CAT7 S/FTP & LKSM-PROFIBUS (IEC 61156-5/6 Cat. 7 (1000 MHz) & IEC 60092-376 / DNV-LR-ABS Approved) featuring stranded 24/7 awg copper pairs (4×2), individual pair foil shields (pimf) and shf1 / shf2 marine data outer jacket (4-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | Stranded 24/7 AWG Copper Pairs (4×2) | Vibration-resistant 7-strand copper with Foam-Skin PE insulation |
| 2 | Individual Pair Foil Shields (PiMF) | 100% Al/PET foil screen on each pair for 1000 MHz Cat.7 isolation |
| 3 | Tinned Copper Braid Overall Shield (S/FT | High-coverage tinned copper wire braid screen |
| 4 | SHF1 / SHF2 Marine Data Outer Jacket | DNV/LR/RINA certified halogen-free flame-retardant sheath |
Built to IEC 61156-5/6 Cat. 7 (1000 MHz) & IEC 60092-376 / DNV-LR-ABS Approved with stranded 24/7 awg copper pairs (4×2) and shf1 / shf2 marine data outer jacket
Available in custom continuous shipboard/offshore drum lengths or with marine EMC cable glands
Supplied with EN 10204 3.1 routine dielectric, conductor resistance & flame/fire test report
Technical data
Sizes
Manufactured to IEC 61156-5/6 Cat. 7 (1000 MHz) & IEC 60092-376 / DNV-LR-ABS Approved for shipboard, offshore platform, drilling rig and marine applications.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Tensile rating kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| LKSM-CAT7 S/FTP & LKSM-PROFIBUS Construction Schedule (−40…+85 °C) | |||||||
| LKSM-CAT7 S 4×2×24 AWG Cat.7 | 4 × 2 × 24/7 AWG S/FTP | Stranded bare/tinned Cu (1000 MHz) | 8.4 | 92 | 0.8 | 68 | |
| LKSM-CAT7 S 1×2×0.64 PROFIBUS | 1 × 2 × 0.64 mm (22 AWG) | Stranded tinned Cu + foil/braid | 9.6 | 128 | 0.9 | 78 | |
| LKSM-CAT7 S 2×2×0.50 CAN-Bus | 2 × 2 × 0.50 mm² (20 AWG) | Stranded tinned Cu + braid | 10.8 | 165 | 1.1 | 86 | |
| Configuration | Max. DC R₂₀ / Atten. Ω/km or dB/km | Rating / Impedance | Operating temp. |
|---|---|---|---|
| 4 × 2 × 24/7 AWG S/FTP | 84.00 | 100 Ω (10GbE Cat. 7) | −40…+85 °C |
| 1 × 2 × 0.64 mm (22 AWG) | 55.00 | 150 Ω (PROFIBUS DP) | −40…+85 °C |
| 2 × 2 × 0.50 mm² (20 AWG) | 39.00 | 120 Ω (Marine CAN-Bus) | −40…+85 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance, continuity & dimensional verification (IEC 61156-5/6 Cat. 7 (1000 MHz) & IEC 60092-376 / DNV-LR-ABS Approved) | DC resistance at 20 °C / optical attenuation and outer diameter within IEC 61156-5/6 Cat. 7 (1000 MHz) & IEC 60092-376 / DNV-LR-ABS Approved tolerances | Every manufactured drum length |
| High-voltage dielectric & insulation resistance test (IEC 61156-5/6 Cat. 7 (1000 MHz) & IEC 60092-376 / DNV-LR-ABS Approved) | Zero dielectric breakdown and verified insulation resistance for 125/250 V rating | Every manufactured drum length |
| Sample tests | ||
| Flame, fire integrity, oil/mud & mechanical qualification (IEC 61156-5/6 Cat. 7 (1000 MHz) & IEC 60092-376 / DNV-LR-ABS Approved) | Verified flame/fire performance, fluid resistance and thermal stability across −40…+85 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.