Fixed installation
IEC 60332-3-22 Cat. A bunched flame-retardant and IEC 60754/61034 low-smoke zero-halogen qualified for enclosed vessel spaces.
Product
LKM-HF & LKM-SHF2 0.6/1 kV & 250 V XLPE-Insulated Unarmoured Lightweight SHF1 / Oil-Resistant SHF2 Shipboard Power & Control Cable (IEC 60092-353, 0.6/1 kV, -40 to +90 °C, min. bend radius 6 × OD).
Typical values for this cable type, based on IEC 60092-353 / IEC 60092-360 SHF1 & SHF2 / IEC 60332-3-22 Cat. A — confirmed in the datasheet and quotation for your order.
Application fit
LKM-HF & LKM-SHF2 0.6/1 kV & 250 V XLPE-Insulated Unarmoured Lightweight SHF1 / Oil-Resistant SHF2 Shipboard Power & Control Cable (IEC 60092-353, 0.6/1 kV, -40 to +90 °C, min. bend radius 6 × OD).
IEC 60332-3-22 Cat. A bunched flame-retardant and IEC 60754/61034 low-smoke zero-halogen qualified for enclosed vessel spaces.
SHF1 and oil-resistant SHF2 outer sheaths withstand engine-room bilge oils, salt fog and marine vibration.
Lightweight unarmoured and braided executions route easily through tight deckhead trays and accommodation modules.
90 °C XLPE/HF-EPR insulation provides high current-carrying capacity in high-ambient marine machinery spaces.
Fixed shipboard LSZH installation cable is not intended for continuous reciprocating drag chains.
Use Drag-Chain Control CableConstruction
Shown: LKM-HF & LKM-SHF2 0.6/1 KV (IEC 60092-353 / IEC 60092-360 SHF1 & SHF2 / IEC 60332-3-22 Cat. A) featuring multi-core copper conductors (12g1.5 mm²), numbered white xlpe insulation and lightweight shf1 / shf2 outer jacket (4-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | Multi-Core Copper Conductors (12G1.5 mm² | 12 stranded annealed copper conductors (IEC 60228 Class 2 / Class 5) |
| 2 | Numbered White XLPE Insulation | White XLPE cores printed 1–11 plus Green/Yellow protective earth |
| 3 | Halogen-Free Separator Tape | Non-hygroscopic polyester binder tape over cabled core assembly |
| 4 | Lightweight SHF1 / SHF2 Outer Jacket | Unarmoured low-smoke zero-halogen polyolefin or oil-resistant SHF2 sheath |
Built to IEC 60092-353 / IEC 60092-360 SHF1 & SHF2 / IEC 60332-3-22 Cat. A with multi-core copper conductors (12g1.5 mm²) and lightweight shf1 / shf2 outer jacket
Available in custom continuous shipboard/offshore drum lengths or with marine EMC cable glands
Supplied with EN 10204 3.1 routine dielectric, conductor resistance & flame/fire test report
Technical data
Sizes
Manufactured to IEC 60092-353 / IEC 60092-360 SHF1 & SHF2 / IEC 60332-3-22 Cat. A for shipboard, offshore platform, drilling rig and marine applications.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Tensile rating kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| LKM-HF & LKM-SHF2 0.6/1 KV Construction Schedule (−40…+90 °C) | |||||||
| LKM-HF 4G2.5 mm² | 4 × 2.5 mm² (or 4C × 14 AWG) | IEC 60228 Class 2/5 Cu/SnCu | 13.2 | 275 | 1.5 | 80 | |
| LKM-HF 7G2.5 mm² | 7 × 2.5 mm² (or 7C × 14 AWG) | IEC 60228 Class 2/5 Cu/SnCu | 15.8 | 415 | 2.6 | 95 | |
| LKM-HF 12G1.5 mm² | 12 × 1.5 mm² (or 12C × 16 AWG) | IEC 60228 Class 2/5 Cu/SnCu | 17.4 | 495 | 2.7 | 105 | |
| Configuration | Max. DC R₂₀ / Atten. Ω/km or dB/km | Rating / Impedance | Operating temp. |
|---|---|---|---|
| 4 × 2.5 mm² (or 4C × 14 AWG) | 7.98 | 0.6/1 kV (26 A) | −40…+90 °C |
| 7 × 2.5 mm² (or 7C × 14 AWG) | 7.98 | 0.6/1 kV (21 A) | −40…+90 °C |
| 12 × 1.5 mm² (or 12C × 16 AWG) | 13.30 | 0.6/1 kV (14 A) | −40…+90 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance, continuity & dimensional verification (IEC 60092-353 / IEC 60092-360 SHF1 & SHF2 / IEC 60332-3-22 Cat. A) | DC resistance at 20 °C / optical attenuation and outer diameter within IEC 60092-353 / IEC 60092-360 SHF1 & SHF2 / IEC 60332-3-22 Cat. A tolerances | Every manufactured drum length |
| High-voltage dielectric & insulation resistance test (IEC 60092-353 / IEC 60092-360 SHF1 & SHF2 / IEC 60332-3-22 Cat. A) | Zero dielectric breakdown and verified insulation resistance for 0.6/1 kV rating | Every manufactured drum length |
| Sample tests | ||
| Flame, fire integrity, oil/mud & mechanical qualification (IEC 60092-353 / IEC 60092-360 SHF1 & SHF2 / IEC 60332-3-22 Cat. A) | Verified flame/fire performance, fluid resistance and thermal stability across −40…+90 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.