Contact
Screened power & VFD / motor supply cablesUL AWM 21223 / 1000 VU0/U 600/1000 V · 4 kV ACHalogen-free PUR

FD-VFD 600/1000 V Drag-Chain Flexible VFD CableContinuous-flex Class 5/6 PUR/TPE shielded VFD energy-chain cable

FD-VFD 600/1000 V Drag Chain combines extra-flexible bare copper conductors, low-capacitance PP/XLPE insulation, ≥ 85% tinned copper braid, and a wear-resistant black PUR/TPE sheath for dynamic VFD carriers.

Low-EMC design
EMC screen
Flame-retardant
Oil-resistant
Order designation
FD-VFD 600/1000V Drag Chain 4G16
Outer Ø
22.4 mm
Max. R20
1.210 Ω/km
Weight
1,128 kg/km
Min. bend R
168 mm
All sizes (13)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
600/1000 V
AC test voltage 4 kV AC
EMC screening
≥ 85% TCWB
Low transfer impedance EMC shield
Temp. (fixed)
-40°C…+90°C
Flexing: -30 °C to +80 °C
Min. bend radius
7.5 × OD
Continuous drag-chain flexing
Conductor
Bare Cu · Cl.5
IEC 60228 stranded copper
Size range
4G1.5–4G185
13 standard configurations

Typical values for this cable type, based on UL AWM 21223 / 1000 V · CSA AWM I/II A/B FT1 · IEC 60228 Class 6 — confirmed in the datasheet and quotation for your order.

Application fit

Is FD-VFD 600/1000V Drag Chain right for your machine?

FD-VFD 600/1000 V Drag Chain combines extra-flexible bare copper conductors, low-capacitance PP/XLPE insulation, ≥ 85% tinned copper braid, and a wear-resistant black PUR/TPE sheath for dynamic VFD carriers.

VFD inverter to AC motor screened feeder

Suitable

Low-capacitance 600/1000 V PUR/TPE construction and EMC screen suppress PWM switching noise between inverter and AC motor.

Energy chain / drag chain

Suitable

Extra-flexible 600/1000 V PUR/TPE stranding and 7.5×D bend rating endure continuous energy-chain flexing.

Factory automation tray & machine bus

Suitable

Flexible oil-resistant 600/1000 V PUR/TPE construction routes cleanly along factory automation trays, machine frames, and production lines.

6-axis robot arm & torsion dress pack

Suitable

Multi-axis torsion-capable 600/1000 V PUR/TPE stranding handles continuous robotic dress-pack twisting and automated assembly cells.

Motorised monospiral reel

Not suitable

600/1000 V PUR/TPE build lacks anti-torsion tensile reinforcement for motorised drum reeling; select a dedicated reeling cable.

Use RG / RG-D (N)SHTOEU-J

Immersion & wet locations

Not suitable

600/1000 V PUR/TPE outer sheath is not AD8-rated for permanent water submersion; specify a submersible EPDM or water-blocked cable.

Use EMC-VFD Submersible EPDM
Typical machinesIndustrial Automation CableVariable frequency drive (VFD) motor baysIndustrial pumps, fans & compressor skidsProcess plants, oil & gas & HVAC systemsHeavy manufacturing & plant MCC feeders

Construction

Layer by layer

Representative construction of FD-VFD 600/1000V Drag Chain: bare copper conductors, Low-capacitance polyolefin / TPE dielectric, Low-friction fleece wrap + ≥ 85% tinned copper braid shield, and Black oil-, coolant- & abrasion-resistant PUR/TPE sheath.

12345
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1ConductorIEC 60228 Class 5 flexible bare annealed copperIEC 60228 Class 5
2Core insulationLow-capacitance polyolefin / TPE dielectricUL AWM 21223 / 1000 V
3Core assembly & separatorConcentric cabled assembly with low-friction fleece or polyester binder tapeUL AWM 21223 / 1000 V
4EMC metallic screenLow-friction fleece wrap + ≥ 85% tinned copper braid shieldEMC ≥ 85% / 100% foil
5Outer sheathBlack oil-, coolant- & abrasion-resistant PUR/TPE sheathUL Oil Res I/II

FD-VFD 600/1000V Drag Chain Power & Ground

Colour-coded or numbered phase conductors with protective green/yellow earth under overall EMC screening.

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on UL AWM 21223 / 1000 V · CSA AWM I/II A/B FT1 · IEC 60228 Class 6. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage U0/U
600/1000 V
AC test voltage
4 kV AC / 5 min
Conductor class
IEC 60228 Class 5 bare Cu
EMC screen
Low-friction fleece wrap + ≥ 85% tinned
Insulation resistance
≥ 1,000 MΩ·km at 20 °C

Thermal

Temp. range (fixed)
-40 °C to +90 °C
Temp. range (flexing)
-30 °C to +80 °C
Short-circuit temp.
+160 °C (5 s)
Min. bending radius
7.5 × OD (flexing)

Resistance

Flame retardance
UL Oil Res I/II
Oil & chemical perf.
IEC 60332-1-2 Flame
Environmental / EMC
5M+ Drag-Chain Cycles
Outer sheath
Black oil-, coolant- & abrasion-resistant

Sizes

4-Core Screened (mm²)
Cores ×
mm²
Outer Ø ≈
mm
Max. R20
Ω/km
Copper index
kg/km
Weight ≈
kg/km
Min. bend R
7.5×D mm
4G1.511.613.3008419187
4G2.512.87.98012325996
4G414.14.950181355106
4G615.53.300257478116
4G1018.71.910411743140
4G1622.41.2106381,128168
4G2525.50.7809741,650191
4G3529.40.5541,3482,261220
4G5033.10.3861,9033,115248
4G7038.30.2722,6444,294287
4G9544.20.2063,5685,778332
4G12048.00.1614,4887,173360
4G18556.30.1066,87510,765422
  • Max. conductor DC resistance R20 at 20 °C per IEC 60228 (bare copper).
  • Minimum bending radius calculated at 7.5 × nominal outer diameter (OD). Custom core counts and lengths available on request.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
AC high-voltage dielectric test4 kV AC for 5 min without breakdownEvery manufactured drum
Conductor DC resistance testPer IEC 60228 at 20 °CEvery drum length
Sample tests
EMC screen coverage & insulation check≥ 85% TCWB continuity & wall thicknessPer production lot
Flame & environmental qualificationUL Oil Res I/II · IEC 60332-1-2 FlameType approval

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

UL AWM 21223 / 1000 VCSA AWM I/II A/B FT1IEC 60228 Class 6EN 10204 3.1 Factory Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

FD-VFD 600/1000V Drag Chain 600/1000 V TEBAOFLEX.COM [UL AWM 21223 / 1000 V] [Size] [Metre mark]
Delivery form
Cut-to-length or wooden export drums
Standard drum lengths
500 m · 1,000 m
MOQ
100 m (stock sizes) · 500 m (production)
Lead time
2–3 weeks ex-works
Incoterms
EXW, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-11-21
Updated
2026-11-21

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What makes FD-VFD 600/1000V Drag Chain suitable for 600/1000 V industrial installations?
FD-VFD 600/1000V Drag Chain combines bare copper conductors, Low-capacitance polyolefin / TPE dielectric, and Low-friction fleece wrap + ≥ 85% tinned copper braid shield inside a Black oil-, coolant- & abrasion-resistant PUR/TPE sheath. 7.5×D continuous bending radius engineered for automated gantries and machine-tool drag chains.
Can FD-VFD 600/1000V Drag Chain operate inside continuous drag chains or moving axes?
Yes. FD-VFD 600/1000V Drag Chain is built for continuous dynamic flexing with a minimum bending radius of 7.5 × OD across -30 °C to +80 °C operating temperatures.
How should the EMC shield of FD-VFD 600/1000V Drag Chain be grounded at termination?
Bond the metallic screen circumferentially (360°) at both drive and motor ends using EMC cable glands or low-impedance shielding clamps to minimize high-frequency transfer impedance.
What standards, drum lengths, and test certificates accompany FD-VFD 600/1000V Drag Chain?
FD-VFD 600/1000V Drag Chain conforms to UL AWM 21223 / 1000 V, CSA AWM I/II A/B FT1, IEC 60228 Class 6 (UL Oil Res I/II) and ships cut-to-length or on export drums with an EN 10204 3.1 routine test certificate.
Which technical documents are available?
Reference files are provided for project screening. Final parameters and the applicable document package are confirmed during quotation.

Request a quote

Get an engineering quote for FD-VFD 600/1000V Drag Chain

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

FD-VFD 600/1000 V Drag-Chain Flexible VFD Cable

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp