Immersion & wet locations
Water-blocked core matrix and hydrolysis-resistant subsea jacketing withstand continuous deepwater hydrostatic pressure.
Product
FCE50 / FCE75 Series 50-Ohm & 75-Ohm Elastic-Core Aramid-Reinforced Polyurethane Oceanographic Coaxial Tow Cable (MIL-C-17 / Subsea, 0.6/1 kV, -30 °C to +80 °C, min. bend radius 10 × OD).
Typical values for this cable type, based on MIL-DTL-17 / Subsea 50 Ω & 75 Ω Sonar Coax Standard — confirmed in the datasheet and quotation for your order.
Application fit
FCE50 / FCE75 Series 50-Ohm & 75-Ohm Elastic-Core Aramid-Reinforced Polyurethane Oceanographic Coaxial Tow Cable (MIL-C-17 / Subsea, 0.6/1 kV, -30 °C to +80 °C, min. bend radius 10 × OD).
Water-blocked core matrix and hydrolysis-resistant subsea jacketing withstand continuous deepwater hydrostatic pressure.
Torque-balanced aramid or contra-helical steel armour supports vertical winch deployment without hockling.
Marine-grade outer sheath and armour package resist LARS sheave abrasion, UV exposure and salt-spray corrosion.
High tensile breaking strength supports underwater towing, ROV excursion and seabed plough/trencher duty.
Subsea umbilical and tow construction is not intended for high-cycle indoor factory drag chains.
Use Drag-Chain Servo CableConstruction
Shown: FCE50 / FCE75 TOW (MIL-DTL-17 / Subsea 50 Ω & 75 Ω Sonar Coax Standard) featuring high-elongation elastic center core, 50 ω / 75 ω pe coaxial dielectric and aramid strength braid & pur jacket (5-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | High-Elongation Elastic Center Core | Special elastic stranded tinned copper core (2× elongation, prevents Z-kinking) |
| 2 | 50 Ω / 75 Ω PE Coaxial Dielectric | Low-dielectric-constant polyethylene insulation (FCE50: 50 Ω, FCE75: 75 Ω) |
| 3 | Braided Tinned Copper Shield | High-coverage tin-plated copper braid serving as return conductor & shield |
| 4 | Elastomer Moisture-Barrier Jacket | Rubber-based elastomer inner barrier jacket with very low moisture permeability |
| 5 | Aramid Strength Braid & PUR Jacket | Torque-balanced Aramid braid (2,500–20,000 lbs) + abrasion-resistant PUR jacket |
Built to MIL-DTL-17 / Subsea 50 Ω & 75 Ω Sonar Coax Standard with high-elongation elastic center core and aramid strength braid & pur jacket
Available in custom continuous subsea/wellbore drum lengths or pre-terminated assemblies
Supplied with EN 10204 3.1 routine dielectric, resistance & pressure/dimensional report
Technical data
Sizes
Manufactured to MIL-DTL-17 / Subsea 50 Ω & 75 Ω Sonar Coax Standard for subsea, offshore, deep-well and marine applications.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Tensile rating kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| FCE50 / FCE75 TOW Construction Schedule (−30…+80 °C) | |||||||
| FCE50 Config A (Compact) | 4×2×24 AWG + 2×18 AWG (or 4C) | Stranded tinned Cu (IEC 60228 / ASTM) | 10.4 | 155 | 4.5 | 85 | |
| FCE50 Config B (Standard) | 4×2×20 AWG + 4×16 AWG (or 8C) | Stranded tinned Cu (IEC 60228 / ASTM) | 13.3 | 265 | 9.6 | 110 | |
| FCE50 Config C (Heavy Hybrid) | 8×2×20 AWG + 4×12 AWG (or 12C) | Stranded tinned Cu (IEC 60228 / ASTM) | 16.6 | 420 | 18.5 | 140 | |
| Configuration | Max. DC R₂₀ / Atten. Ω/km or dB/km | Rating / Impedance | Operating temp. |
|---|---|---|---|
| 4×2×24 AWG + 2×18 AWG (or 4C) | 28.40 | 0.6/1 kV (45–100 Ω data) | −30…+80 °C |
| 4×2×20 AWG + 4×16 AWG (or 8C) | 10.70 | 0.6/1 kV (45–100 Ω data) | −30…+80 °C |
| 8×2×20 AWG + 4×12 AWG (or 12C) | 5.40 | 0.6/1 kV (High-Power Hybrid) | −30…+80 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance, continuity & dimensional verification (MIL-DTL-17 / Subsea 50 Ω & 75 Ω Sonar Coax Standard) | DC resistance at 20 °C / optical attenuation and outer diameter within MIL-DTL-17 / Subsea 50 Ω & 75 Ω Sonar Coax Standard tolerances | Every manufactured drum length |
| High-voltage dielectric & insulation resistance test (MIL-DTL-17 / Subsea 50 Ω & 75 Ω Sonar Coax Standard) | Zero dielectric breakdown and verified insulation resistance for 0.6/1 kV rating | Every manufactured drum length |
| Sample tests | ||
| Hydrostatic pressure, water-blocking & mechanical endurance qualification (MIL-DTL-17 / Subsea 50 Ω & 75 Ω Sonar Coax Standard) | Verified submersion integrity, tensile load and thermal stability across −30…+80 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking