Immersion & wet locations
Water-blocked core matrix and hydrolysis-resistant subsea jacketing withstand continuous deepwater hydrostatic pressure.
Product
(F)2XS(FL)2YRAA 19/33 kV Offshore Wind Inter-Array Cable (DIN VDE 0276-620 / IEC 60502-2) engineered for 19/33 kV service across -20 °C to +90 °C (min. bend radius 15 × OD).
Typical values for this cable type, based on DIN VDE 0276-620 / IEC 60502-2 — confirmed in the datasheet and quotation for your order.
Application fit
(F)2XS(FL)2YRAA 19/33 kV Offshore Wind Inter-Array Cable (DIN VDE 0276-620 / IEC 60502-2) engineered for 19/33 kV service across -20 °C to +90 °C (min. bend radius 15 × OD).
Water-blocked core matrix and hydrolysis-resistant subsea jacketing withstand continuous deepwater hydrostatic pressure.
Torque-balanced aramid or contra-helical steel armour supports vertical winch deployment without hockling.
Marine-grade outer sheath and armour package resist LARS sheave abrasion, UV exposure and salt-spray corrosion.
High tensile breaking strength supports underwater towing, ROV excursion and seabed plough/trencher duty.
Subsea umbilical and tow construction is not intended for high-cycle indoor factory drag chains.
Use Drag-Chain Servo CableConstruction
Shown: (F)2XS(FL)2YRAA (DIN VDE 0276-620 / IEC 60502-2) featuring water-blocked phase cores (3×500 mm²), cu wire screen & al-pe laminate s(fl)2y>c< and hessian & pp roving outer serving (aa) (5-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | Water-Blocked Phase Cores (3×500 mm²) | Class 2 longitudinal water-blocked Cu (F) + semicon + 8.0 mm 36 kV XLPE (2X) |
| 2 | Cu Wire Screen & Al-PE Laminate S(FL)2Y>c< | 25 mm² Cu wire/tape screen + swelling powder (FL) + Al foil laminate + HDPE sheath |
| 3 | Integrated Subsea FO Cable & PP Fillers | Armoured single-mode optical cable unit(s) + polypropylene string fillers in valleys |
| 4 | Galvanized Round Steel Wire Armour (R) | 54–68 × Ø4.0–4.75 mm galvanized steel wires embedded in bitumen over bedding |
| 5 | Hessian & PP Roving Outer Serving (AA) | Two bitumen-impregnated Hessian tapes + black/yellow polypropylene yarn serving |
Built to DIN VDE 0276-620 / IEC 60502-2 with water-blocked phase cores (3×500 mm²) and hessian & pp roving outer serving (aa)
Available in custom continuous subsea/wellbore drum lengths or pre-terminated assemblies
Supplied with EN 10204 3.1 routine dielectric, resistance & pressure/dimensional report
Technical data
Sizes
Manufactured to DIN VDE 0276-620 / IEC 60502-2 for subsea, offshore, deep-well and marine applications.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Tensile rating kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| (F)2XS(FL)2YRAA Construction Schedule (−20…+90 °C) | |||||||
| (F)2XS(FL)2YRAA 3×240 mm² + FO | 3 × 240 mm² + 48F FIMT | IEC 60228 Class 2 water-blocked Cu | 118.0 | 26,400 | 320.0 | 1,770 | |
| (F)2XS(FL)2YRAA 3×400 mm² + FO | 3 × 400 mm² + 48F FIMT | IEC 60228 Class 2 water-blocked Cu | 134.0 | 34,800 | 420.0 | 2,010 | |
| (F)2XS(FL)2YRAA 3×630 mm² + FO | 3 × 630 mm² + 96F FIMT | IEC 60228 Class 2 water-blocked Cu | 152.0 | 46,200 | 560.0 | 2,280 | |
| Configuration | Max. DC R₂₀ / Atten. Ω/km or dB/km | Rating / Impedance | Operating temp. |
|---|---|---|---|
| 3 × 240 mm² + 48F FIMT | 0.08 | 19/33 kV (560 A) | −20…+90 °C |
| 3 × 400 mm² + 48F FIMT | 0.05 | 19/33 kV (710 A) | −20…+90 °C |
| 3 × 630 mm² + 96F FIMT | 0.03 | 19/33 kV (890 A) | −20…+90 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance, continuity & dimensional verification (DIN VDE 0276-620 / IEC 60502-2) | DC resistance at 20 °C / optical attenuation and outer diameter within DIN VDE 0276-620 / IEC 60502-2 tolerances | Every manufactured drum length |
| High-voltage dielectric & insulation resistance test (DIN VDE 0276-620 / IEC 60502-2) | Zero dielectric breakdown and verified insulation resistance for 19/33 kV rating | Every manufactured drum length |
| Sample tests | ||
| Hydrostatic pressure, water-blocking & mechanical endurance qualification (DIN VDE 0276-620 / IEC 60502-2) | Verified submersion integrity, tensile load and thermal stability across −20…+90 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.