Motorised monospiral reel
Engineered for horizontal and mobile drum reeling duty per DIN VDE 0250 / IEC 60754-1 / IEC 60332-1-2 within 8 × OD.
Product
Engineered for underground mining, open-cast excavation, shaft infrastructure and heavy industrial service per DIN VDE 0250 / IEC 60754-1 / IEC 60332-1-2 across -40 to +90 °C.
Typical values for this cable type, based on DIN VDE 0250 / IEC 60754-1 / IEC 60332-1-2 — confirmed in the datasheet and quotation for your order.
Application fit
Engineered for underground mining, open-cast excavation, shaft infrastructure and heavy industrial service per DIN VDE 0250 / IEC 60754-1 / IEC 60332-1-2 across -40 to +90 °C.
Engineered for horizontal and mobile drum reeling duty per DIN VDE 0250 / IEC 60754-1 / IEC 60332-1-2 within 8 × OD.
Suitable for mobile mining loader, shuttle car and excavator trailing service across -40 to +90 °C.
Verified for underground mining galleries, tunnel faces and open-cast haulage paths.
Not optimized for high-speed overhead crane C-track festoon loops; select a dedicated festoon cable.
NGFLGÖU Flat Rubber Festoon CableConstruction
Shown: D2X11Y (DIN VDE 0250 / IEC 60754-1 / IEC 60332-1-2) featuring central aramid core, phase conductors (3×35 mm²) and outer sheath (11y halogen-free pur) (5-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | Central Aramid Core | Polymer-sheathed high-modulus aramid fibre strain-relief core (20–25 N/mm²) |
| 2 | Phase Conductors (3×35 mm²) | IEC 60228 Class 5 flexible plain copper with Black, Brown & Grey XLPE (2X) |
| 3 | Split Earth & Pilot Cores | 3 × 6 mm² Green/Yellow XLPE earth cores + 2 × 1.5 mm² White/Blue XLPE pilots |
| 4 | Inner Polyurethane Sheath | Extruded high-elasticity special PUR inner bedding locking core geometry |
| 5 | Outer Sheath (11Y Halogen-Free PUR) | Dull yellow rock-cut, oil- and abrasion-resistant halogen-free PUR jacket |
Built to DIN VDE 0250 / IEC 60754-1 / IEC 60332-1-2 with central aramid core and outer sheath (11y halogen-free pur)
Available in custom shaft/roadway drum lengths or pre-terminated assemblies
Supplied with EN 10204 3.1 routine dielectric, resistance & flame test report
Technical data
Sizes
Manufactured to DIN VDE 0250 / IEC 60754-1 / IEC 60332-1-2 for underground mining, open-cast excavation, shaft and heavy industrial systems.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Tensile rating kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| D2X11Y Construction Schedule (-40 to +90 °C) | |||||||
| D2X11Y 3×25 + 3×6G + 2×1.5P | 3×25 + 3×6 (G) + 2×1.5 (P) | Class 5 plain Cu + Aramid | 28.4 | 1,380 | 18.5 | 230 | |
| D2X11Y 3×35 + 3×6G + 2×1.5P | 3×35 + 3×6 (G) + 2×1.5 (P) | Class 5 plain Cu + Aramid | 31.6 | 1,760 | 24.0 | 255 | |
| D2X11Y 3×50 + 3×10G + 2×1.5P | 3×50 + 3×10 (G) + 2×1.5 (P) | Class 5 plain Cu + Aramid | 36.2 | 2,440 | 32.5 | 290 | |
| Configuration | Max. DC R₂₀ / Atten. Ω/km or dB/km | Rating / Impedance | Operating temp. |
|---|---|---|---|
| 3×25 + 3×6 (G) + 2×1.5 (P) | 0.78 | 0.6/1 kV (131 A) | -40 to +90 °C |
| 3×35 + 3×6 (G) + 2×1.5 (P) | 0.55 | 0.6/1 kV (162 A) | -40 to +90 °C |
| 3×50 + 3×10 (G) + 2×1.5 (P) | 0.39 | 0.6/1 kV (202 A) | -40 to +90 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance, continuity & dimensional verification (DIN VDE 0250 / IEC 60754-1 / IEC 60332-1-2) | DC resistance at 20 °C / optical attenuation and outer diameter within DIN VDE 0250 / IEC 60754-1 / IEC 60332-1-2 tolerances | Every manufactured drum length |
| High-voltage dielectric & insulation resistance test (DIN VDE 0250 / IEC 60754-1 / IEC 60332-1-2) | Zero dielectric breakdown and verified insulation resistance over full production length | Every manufactured drum length |
| Sample tests | ||
| Flame propagation, mechanical crush & thermal ageing qualification (DIN VDE 0250 / IEC 60754-1 / IEC 60332-1-2) | Verified flame retardancy, mechanical integrity and thermal endurance across -40 to +90 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.