Fixed installation
High-density multi-core construction routes compactly through marine cable trays, bulkheads and equipment racks.
Product
DEF STAN 61-12 Part 25 & NES 525 / NES 526 440/600 V LFH Naval Shipboard Cable (DEF STAN 02-525 / 02-526) engineered for 440/600 V service across -30 to +105 °C (min. bend radius 6 × OD).
Typical values for this cable type, based on UK MoD DEF STAN 02-525 (NES 525) / 02-526 (NES 526) & DEF STAN 61-12 Part 25 — confirmed in the datasheet and quotation for your order.
Application fit
DEF STAN 61-12 Part 25 & NES 525 / NES 526 440/600 V LFH Naval Shipboard Cable (DEF STAN 02-525 / 02-526) engineered for 440/600 V service across -30 to +105 °C (min. bend radius 6 × OD).
High-density multi-core construction routes compactly through marine cable trays, bulkheads and equipment racks.
Number-coded or colour-coded cores simplify termination inside marine switchgear, bridge consoles and control panels.
Cross-linked LFH/SHF1/Type P jacket resists marine oils, lubricants, moisture and mechanical abrasion.
High-coverage copper or bronze braid provides both mechanical protection and 360° EMC screening.
Fixed shipboard and naval control cable is not intended for vertical deepwater lift winches.
Use A304739 BOP MUX UmbilicalConstruction
Shown: DEF STAN 61-12 PART 25 & NES 525 / NES 526 (LFH) (UK MoD DEF STAN 02-525 (NES 525) / 02-526 (NES 526) & DEF STAN 61-12 Part 25) featuring flexible tinned copper (7×1.5 mm²), thin-wall lfh cross-linked insulation and nes 518 low fire hazard (lfh) sheath (4-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | Flexible Tinned Copper (7×1.5 mm²) | Class 5 tinned annealed copper conductors per BS EN 60228 |
| 2 | Thin-Wall LFH Cross-Linked Insulation | White number-coded Low Fire Hazard cross-linked insulation |
| 3 | Tinned Copper / Steel Braid (NES 526 / 5 | Braided tinned copper screen or galvanized steel wire armour |
| 4 | NES 518 Low Fire Hazard (LFH) Sheath | Black low-smoke zero-halogen low-toxicity elastomer jacket (NES 713) |
Built to UK MoD DEF STAN 02-525 (NES 525) / 02-526 (NES 526) & DEF STAN 61-12 Part 25 with flexible tinned copper (7×1.5 mm²) and nes 518 low fire hazard (lfh) sheath
Available in custom continuous shipboard/offshore drum lengths or with marine EMC cable glands
Supplied with EN 10204 3.1 routine dielectric, conductor resistance & flame/fire test report
Technical data
Sizes
Manufactured to UK MoD DEF STAN 02-525 (NES 525) / 02-526 (NES 526) & DEF STAN 61-12 Part 25 for shipboard, offshore platform, drilling rig and marine applications.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Tensile rating kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| DEF STAN 61-12 PART 25 & NES 525 / NES 526 (LFH) Construction Schedule (−30…+105 °C) | |||||||
| DEF STAN 61-12 PART 25 4G2.5 mm² | 4 × 2.5 mm² (or 4C × 14 AWG) | IEC 60228 Class 2/5 Cu/SnCu | 13.2 | 275 | 1.5 | 80 | |
| DEF STAN 61-12 PART 25 7G2.5 mm² | 7 × 2.5 mm² (or 7C × 14 AWG) | IEC 60228 Class 2/5 Cu/SnCu | 15.8 | 415 | 2.6 | 95 | |
| DEF STAN 61-12 PART 25 12G1.5 mm² | 12 × 1.5 mm² (or 12C × 16 AWG) | IEC 60228 Class 2/5 Cu/SnCu | 17.4 | 495 | 2.7 | 105 | |
| Configuration | Max. DC R₂₀ / Atten. Ω/km or dB/km | Rating / Impedance | Operating temp. |
|---|---|---|---|
| 4 × 2.5 mm² (or 4C × 14 AWG) | 7.98 | 440/600 V (26 A) | −30…+105 °C |
| 7 × 2.5 mm² (or 7C × 14 AWG) | 7.98 | 440/600 V (21 A) | −30…+105 °C |
| 12 × 1.5 mm² (or 12C × 16 AWG) | 13.30 | 440/600 V (14 A) | −30…+105 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance, continuity & dimensional verification (UK MoD DEF STAN 02-525 (NES 525) / 02-526 (NES 526) & DEF STAN 61-12 Part 25) | DC resistance at 20 °C / optical attenuation and outer diameter within UK MoD DEF STAN 02-525 (NES 525) / 02-526 (NES 526) & DEF STAN 61-12 Part 25 tolerances | Every manufactured drum length |
| High-voltage dielectric & insulation resistance test (UK MoD DEF STAN 02-525 (NES 525) / 02-526 (NES 526) & DEF STAN 61-12 Part 25) | Zero dielectric breakdown and verified insulation resistance for 440/600 V rating | Every manufactured drum length |
| Sample tests | ||
| Flame, fire integrity, oil/mud & mechanical qualification (UK MoD DEF STAN 02-525 (NES 525) / 02-526 (NES 526) & DEF STAN 61-12 Part 25) | Verified flame/fire performance, fluid resistance and thermal stability across −30…+105 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.