Contact
6,000 m deepwater Gigabit Ethernet & power wet-mate PUR cable6,000 m (8,700 psi)100±15 Ω Gigabit + 600 V95A Wet-Mateable PUR

D/P-P4TP24#/4C18#-A 6,000m Deepwater Gigabit & Power Wet-Mate Cable6,000m Gigabit Wet-Mate · 600 V · 6,000 m deepwater gigabit ethernet & power wet-mate

Wet-Mate Deepwater 6,000m Gigabit Ethernet & Power/Data Hybrid Underwater PUR Cable Family (D/P4TP24#-A, D/P-P4TP24#/4C18#-A, D/P4TP22#/4C18#OS, D/P4TP24#SW) (6,000m Gigabit Wet-Mate, 600 V, -30 °C to +80 °C, min. bend radius 10 × OD).

Water-resistant
EMC screen
Low-EMC design
Oil-resistant
Order designation
D/P-P4TP24#/4C18#- Config A (Compact)
Outer Ø ≈
10.4 mm
Net weight ≈
155 kg/km
Tensile rating ≈
4.5 kN
Core / stranding
Stranded tinned Cu (IEC 60228 / ASTM)
All sizes (3)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
600 V
Tested per 6,000m Gigabit Wet-Mate
Operating temp.
−30…+80 °C
Continuous subsea & marine service
Min. bend radius
10 × OD
Dynamic sheave & fixed routing
Core / conductor
4×2×24 AWG
Silver-plated Cu PTFE/TPE belt-to-round
Outer protection
Dark-Blue 95A
Water-blocked interstices
Standard
6,000m Gigabit
ISO/IEC 11801

Typical values for this cable type, based on ISO/IEC 11801 / 6,000 m (8,700 psi) Wet-Mate Gigabit Hybrid — confirmed in the datasheet and quotation for your order.

Application fit

Is D/P-P4TP24#/4C18#-A right for your machine?

Wet-Mate Deepwater 6,000m Gigabit Ethernet & Power/Data Hybrid Underwater PUR Cable Family (D/P4TP24#-A, D/P-P4TP24#/4C18#-A, D/P4TP22#/4C18#OS, D/P4TP24#SW) (6,000m Gigabit Wet-Mate, 600 V, -30 °C to +80 °C, min. bend radius 10 × OD).

Immersion & wet locations

Suitable

Water-blocked core matrix and hydrolysis-resistant subsea jacketing withstand continuous deepwater hydrostatic pressure.

Vertical / spreader reel

Suitable

Torque-balanced aramid or contra-helical steel armour supports vertical winch deployment without hockling.

Offshore platform & shipboard deck trays

Suitable

Marine-grade outer sheath and armour package resist LARS sheave abrasion, UV exposure and salt-spray corrosion.

Trailing & towing

Suitable

High tensile breaking strength supports underwater towing, ROV excursion and seabed plough/trencher duty.

Energy chain / drag chain

Not suitable

Subsea umbilical and tow construction is not intended for high-cycle indoor factory drag chains.

Use Drag-Chain Servo Cable
Typical machinesMarine & Offshore CableWork-Class & Observation ROV SystemsOffshore Wind & Subsea Power GridsOceanographic, Sonar & Seismic SurveyCommercial Diving & Subsea Intervention

Construction

Layer by layer

Shown: D/P-P4TP24#/4C18#-A (ISO/IEC 11801 / 6,000 m (8,700 psi) Wet-Mate Gigabit Hybrid) featuring tpe belt-to-round gigabit pairs (4×2×24 awg), power conductors (4×18 awg, 600 v / 4 a) and dark blue 95a pur outer jacket (ø13.3 mm) (5-layer construction).

12345
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1TPE Belt-to-Round Gigabit Pairs (4×2×24 AWG)Silver-plated Cu + PTFE insulation + individual TPE round belt (100±15 Ω @ 6,000 m)
2Power Conductors (4×18 AWG, 600 V / 4 A)Stranded tinned copper with Black, White, Red & Green ETFE insulation
3Nylon Center Rod & Waterblocking FillCentral nylon rod + elastomeric water-blocking compound in all interstices
4Foil + Tinned Copper Braid Screen100% Aluminium/Polyester tape + 24 AWG drain wire + ≥85% tinned copper braid
5Dark Blue 95A PUR Outer Jacket (Ø13.3 mm)High-durometer (95 Shore A) dark-blue halogen-free polyurethane sheath

D/P-P4TP24#/4C18#-A — Standard Subsea & Marine Execution

Built to ISO/IEC 11801 / 6,000 m (8,700 psi) Wet-Mate Gigabit Hybrid with tpe belt-to-round gigabit pairs (4×2×24 awg) and dark blue 95a pur outer jacket (ø13.3 mm)

D/P-P4TP24#/4C18#-A — Custom Drum Length & Termination Kit

Available in custom continuous subsea/wellbore drum lengths or pre-terminated assemblies

D/P-P4TP24#/4C18#-A — Routine & Hydrostatic Test Certified

Supplied with EN 10204 3.1 routine dielectric, resistance & pressure/dimensional report

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on ISO/IEC 11801 / 6,000 m (8,700 psi) Wet-Mate Gigabit Hybrid. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage / transmission duty
600 V (ISO/IEC 11801 / 6,000 m (8,700 psi) Wet-Mate Gigabit Hybrid)
Core / conductor construction
TPE Belt-to-Round Gigabit Pairs (4×2×24 AWG) — Silver-plated Cu + PTFE insulation + individual TPE round belt (100±15 Ω @ 6,000 m)
Primary dielectric / buffering
Power Conductors (4×18 AWG, 600 V / 4 A) — Stranded tinned copper with Black, White, Red & Green ETFE insulation

Thermal

Continuous operating temperature
−30…+80 °C (subsea, marine & submersible duty)
Short-circuit / peak thermal rating
Verified thermal stability per ISO/IEC 11801 / 6,000 m (8,700 psi) Wet-Mate Gigabit Hybrid
Storage & transport temperature
−40…+80 °C on export wooden/steel drum

Mechanical

Outer protection / armouring
Dark Blue 95A PUR Outer Jacket (Ø13.3 mm) — High-durometer (95 Shore A) dark-blue halogen-free polyurethane sheath
Minimum bending radius
10 × OD
Hydrostatic, tensile & crush duty
Foil + Tinned Copper Braid Screen — 100% Aluminium/Polyester tape + 24 AWG drain wire + ≥85% tinned copper braid

Resistance

Hydrostatic pressure & water blocking
Engineered for continuous submersion and hydrostatic integrity per ISO/IEC 11801 / 6,000 m (8,700 psi) Wet-Mate Gigabit Hybrid
Seawater, oil & chemical resistance
Resistant to seawater hydrolysis, hydraulic oils and abrasion per ISO/IEC 11801 / 6,000 m (8,700 psi) Wet-Mate Gigabit Hybrid
RoHS & REACH compliance
RoHS 2 (2011/65/EU + 2015/863) & REACH SVHC compliant

Reference standards

Governing standard
ISO/IEC 11801 / 6,000 m (8,700 psi) Wet-Mate Gigabit Hybrid
Environmental & test standards
IEC 60228 / IEC 60332 / ISO 13628-5 / EN 10204
Quality management & inspection
ISO 9001:2015 & EN 10204 3.1 factory routine inspection

Identification

Model designation
D/P-P4TP24#/4C18#-A
Sheath colour & metre marking
Continuous metre-marked blue outer finish (Dark-Blue 95A PUR (Ø13.3))
Customs tariff (HS)
8544.49 / 8544.60 / 8544.70

Sizes

3 standard D/P-P4TP24#/4C18#-A subsea & marine configurations

Manufactured to ISO/IEC 11801 / 6,000 m (8,700 psi) Wet-Mate Gigabit Hybrid for subsea, offshore, deep-well and marine applications.

Dimensions, tensile load & weights
Order designationConfigurationCore / strandingOuter Ø ≈
mm
Net weight ≈
kg/km
Tensile rating
kN ≈
Min. bend R
mm
Enquiry
D/P-P4TP24#/4C18#-A Construction Schedule (−30…+80 °C)
D/P-P4TP24#/4C18#- Config A (Compact)4×2×24 AWG + 2×18 AWG (or 4C)Stranded tinned Cu (IEC 60228 / ASTM)10.41554.585
D/P-P4TP24#/4C18#- Config B (Standard)4×2×20 AWG + 4×16 AWG (or 8C)Stranded tinned Cu (IEC 60228 / ASTM)13.32659.6110
D/P-P4TP24#/4C18#- Config C (Heavy Hybrid)8×2×20 AWG + 4×12 AWG (or 12C)Stranded tinned Cu (IEC 60228 / ASTM)16.642018.5140
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Custom core cross-sections, pair/fibre counts, armour grades and factory drum lengths available per ISO/IEC 11801 / 6,000 m (8,700 psi) Wet-Mate Gigabit Hybrid.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
Conductor resistance, continuity & dimensional verification (ISO/IEC 11801 / 6,000 m (8,700 psi) Wet-Mate Gigabit Hybrid)DC resistance at 20 °C / optical attenuation and outer diameter within ISO/IEC 11801 / 6,000 m (8,700 psi) Wet-Mate Gigabit Hybrid tolerancesEvery manufactured drum length
High-voltage dielectric & insulation resistance test (ISO/IEC 11801 / 6,000 m (8,700 psi) Wet-Mate Gigabit Hybrid)Zero dielectric breakdown and verified insulation resistance for 600 V ratingEvery manufactured drum length
Sample tests
Hydrostatic pressure, water-blocking & mechanical endurance qualification (ISO/IEC 11801 / 6,000 m (8,700 psi) Wet-Mate Gigabit Hybrid)Verified submersion integrity, tensile load and thermal stability across −30…+80 °CType qualification & periodic lot audit

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

6,000m Gigabit Wet-Mate CompliantEN 10204 3.1 Factory Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

TEBAOFLEX D/P-P4TP24#/4C18#-A 6,000m Gigabit Wet-Mate 600 V CE
Delivery form
Heavy-duty export fumigated wooden drums or steel subsea reels
Standard lengths
500 m, 1,000 m or custom continuous subsea/wellbore lengths
MOQ
100 m (standard configurations) · 500 m (custom builds)
Lead time
2–5 weeks ex-works
Incoterms
EXW, FCA, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-10-25
Updated
2026-10-25

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What governing standard and construction define D/P-P4TP24#/4C18#-A (D/P-P4TP24#/4C18#-A 6,000m Deepwater Gigabit & Power Wet-Mate Cable)?
D/P-P4TP24#/4C18#-A (D/P-P4TP24#/4C18#-A 6,000m Deepwater Gigabit & Power Wet-Mate Cable) is manufactured in accordance with ISO/IEC 11801 / 6,000 m (8,700 psi) Wet-Mate Gigabit Hybrid for 600 V service over -30 °C to +80 °C. Its 5-layer construction comprises tpe belt-to-round gigabit pairs (4×2×24 awg), power conductors (4×18 awg, 600 v / 4 a) and dark blue 95a pur outer jacket (ø13.3 mm).
What is the minimum bending radius and operating temperature range for D/P-P4TP24#/4C18#-A?
The minimum bending radius for D/P-P4TP24#/4C18#-A is 10 × OD across its continuous operating temperature range of -30 °C to +80 °C, ensuring mechanical and dielectric reliability in subsea, marine and submersible service.
How are the concentric layers of D/P-P4TP24#/4C18#-A arranged from inside to outside?
From inside to outside, the construction sequence is: (01) TPE Belt-to-Round Gigabit Pairs (4×2×24 AWG) — Silver-plated Cu + PTFE insulation + individual TPE round belt (100±15 Ω @ 6,000 m); (02) Power Conductors (4×18 AWG, 600 V / 4 A) — Stranded tinned copper with Black, White, Red & Green ETFE insulation; (03) Nylon Center Rod & Waterblocking Fill — Central nylon rod + elastomeric water-blocking compound in all interstices; (04) Foil + Tinned Copper Braid Screen — 100% Aluminium/Polyester tape + 24 AWG drain wire + ≥85% tinned copper braid; (05) Dark Blue 95A PUR Outer Jacket (Ø13.3 mm) — High-durometer (95 Shore A) dark-blue halogen-free polyurethane sheath.
What factory test certificates are supplied with D/P-P4TP24#/4C18#-A?
Every production drum of D/P-P4TP24#/4C18#-A undergoes routine conductor resistance/continuity, high-voltage dielectric and dimensional testing per ISO/IEC 11801 / 6,000 m (8,700 psi) Wet-Mate Gigabit Hybrid, and is delivered with an EN 10204 3.1 factory test certificate.

Request a quote

Get an engineering quote for D/P-P4TP24#/4C18#-A

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

D/P-P4TP24#/4C18#-A 6,000m Deepwater Gigabit & Power Wet-Mate Cable

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote