Contact

CLEAN CABLE & CLEAN CABLE EMV 0.6/1 kV 600m Potable-Water Pump CableACS / KTW / WRAS / DM174 · 0.6/1 kV · 600 m xlpe/rubber potable-water round, flat &

CLEAN CABLE (Round / Flat) & CLEAN CABLE EMV (Screened Round) 0.6/1 kV XLPE-Insulated Cross-Linked Rubber Sheathed Potable Water Submersible Pump Cable (ACS / KTW / WRAS / DM174, 0.6/1 kV, -40 °C to +90 °C, min. bend radius 6 × OD).

Water-resistant
EMC screen
Low-EMC design
Approved
Order designation
CLEAN CABLE 4G16 mm²
Outer Ø ≈
21.8 mm
Net weight ≈
840 kg/km
Tensile rating ≈
2.4 kN
Core / stranding
IEC 60228 Class 5 flexible Cu/SnCu
All sizes (3)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
0.6/1 kV
Tested per ACS / KTW / WRAS / DM174
Operating temp.
−40…+90 °C
Continuous subsea & marine service
Min. bend radius
6 × OD
Dynamic sheave & fixed routing
Core / conductor
3G–4G 1.5–150
CEI EN 60228 Class 5 flexible bare Cu
Outer protection
RAL 5015
Food-grade cross-linked rubber
Standard
ACS / KTW / WRAS
CEI EN 60228

Typical values for this cable type, based on CEI EN 60228 / ACS, KTW/W270, WRAS & DM 174 Potable Rubber — confirmed in the datasheet and quotation for your order.

Application fit

Is CLEAN CABLE / CLEAN CABLE EMV right for your machine?

CLEAN CABLE (Round / Flat) & CLEAN CABLE EMV (Screened Round) 0.6/1 kV XLPE-Insulated Cross-Linked Rubber Sheathed Potable Water Submersible Pump Cable (ACS / KTW / WRAS / DM174, 0.6/1 kV, -40 °C to +90 °C, min. bend radius 6 × OD).

Immersion & wet locations

Suitable

Cross-linked submersible elastomer compound is qualified for continuous deep-well, potable-water or sewage immersion.

Free-hanging vertical run

Suitable

High-modulus conductor and elastomer construction supports vertical suspension in deep boreholes and pump risers.

Trailing & towing

Suitable

Tear- and abrasion-resistant rubber outer sheath handles mobile dewatering, dredger and portable pump deployment.

Fixed installation

Suitable

Suitable for permanent wet-well, treatment tank, geothermal borehole and submergedmanifold installations.

Energy chain / drag chain

Not suitable

Submersible rubber pump cable is not intended for high-acceleration automation drag chains.

Use Drag-Chain Control Cable
Typical machinesDeep-Well Potable Water PumpingMunicipal Sewage & Wastewater PlantsMine Dewatering & Slurry DredgingGeothermal, Spa & Pool Installations

Construction

Layer by layer

Shown: CLEAN CABLE / CLEAN CABLE EMV (CEI EN 60228 / ACS, KTW/W270, WRAS & DM 174 Potable Rubber) featuring class 5 bare copper conductors (4g1.5–50), high-insulation xlpe dielectric (>200 mω·km) and ral 5015 sky-blue cross-linked rubber sheath (4-layer construction).

1234
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1Class 5 Bare Copper Conductors (4G1.5–50)CEI EN 60228 Class 5 flexible annealed bare copper conductors
2High-Insulation XLPE Dielectric (>200 MΩ·km)Low-capacitance cross-linked polyethylene insulation (Brown, Black, Grey & G/Y)
3Overall Tinned Copper Braid (EMV, ≥85%)High-coverage tinned copper wire braid for VFD inverter EMC & bearing protection
4RAL 5015 Sky-Blue Cross-Linked Rubber SheathFood-grade rubber jacket (≤0.5% halogen; ACS, KTW/W270, WRAS & DM 174 certified)

CLEAN CABLE / CLEAN CABLE EMV — Standard Subsea & Marine Execution

Built to CEI EN 60228 / ACS, KTW/W270, WRAS & DM 174 Potable Rubber with class 5 bare copper conductors (4g1.5–50) and ral 5015 sky-blue cross-linked rubber sheath

CLEAN CABLE / CLEAN CABLE EMV — Custom Drum Length & Termination Kit

Available in custom continuous subsea/wellbore drum lengths or pre-terminated assemblies

CLEAN CABLE / CLEAN CABLE EMV — Routine & Hydrostatic Test Certified

Supplied with EN 10204 3.1 routine dielectric, resistance & pressure/dimensional report

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on CEI EN 60228 / ACS, KTW/W270, WRAS & DM 174 Potable Rubber. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage / transmission duty
0.6/1 kV (CEI EN 60228 / ACS, KTW/W270, WRAS & DM 174 Potable Rubber)
Core / conductor construction
Class 5 Bare Copper Conductors (4G1.5–50) — CEI EN 60228 Class 5 flexible annealed bare copper conductors
Primary dielectric / buffering
High-Insulation XLPE Dielectric (>200 MΩ·km) — Low-capacitance cross-linked polyethylene insulation (Brown, Black, Grey & G/Y)

Thermal

Continuous operating temperature
−40…+90 °C (subsea, marine & submersible duty)
Short-circuit / peak thermal rating
Verified thermal stability per CEI EN 60228 / ACS, KTW/W270, WRAS & DM 174 Potable Rubber
Storage & transport temperature
−40…+80 °C on export wooden/steel drum

Mechanical

Outer protection / armouring
RAL 5015 Sky-Blue Cross-Linked Rubber Sheath — Food-grade rubber jacket (≤0.5% halogen; ACS, KTW/W270, WRAS & DM 174 certified)
Minimum bending radius
6 × OD
Hydrostatic, tensile & crush duty
Overall Tinned Copper Braid (EMV, ≥85%) — High-coverage tinned copper wire braid for VFD inverter EMC & bearing protection

Resistance

Hydrostatic pressure & water blocking
Engineered for continuous submersion and hydrostatic integrity per CEI EN 60228 / ACS, KTW/W270, WRAS & DM 174 Potable Rubber
Seawater, oil & chemical resistance
Resistant to seawater hydrolysis, hydraulic oils and abrasion per CEI EN 60228 / ACS, KTW/W270, WRAS & DM 174 Potable Rubber
RoHS & REACH compliance
RoHS 2 (2011/65/EU + 2015/863) & REACH SVHC compliant

Reference standards

Governing standard
CEI EN 60228 / ACS, KTW/W270, WRAS & DM 174 Potable Rubber
Environmental & test standards
IEC 60228 / IEC 60332 / ISO 13628-5 / EN 10204
Quality management & inspection
ISO 9001:2015 & EN 10204 3.1 factory routine inspection

Identification

Model designation
CLEAN CABLE / CLEAN CABLE EMV
Sheath colour & metre marking
Continuous metre-marked blue outer finish (RAL 5015 Sky-Blue Rubber)
Customs tariff (HS)
8544.49 / 8544.60 / 8544.70

Sizes

3 standard CLEAN CABLE / CLEAN CABLE EMV subsea & marine configurations

Manufactured to CEI EN 60228 / ACS, KTW/W270, WRAS & DM 174 Potable Rubber for subsea, offshore, deep-well and marine applications.

Dimensions, tensile load & weights
Order designationConfigurationCore / strandingOuter Ø ≈
mm
Net weight ≈
kg/km
Tensile rating
kN ≈
Min. bend R
mm
Enquiry
CLEAN CABLE / CLEAN CABLE EMV Construction Schedule (−40…+90 °C)
CLEAN CABLE 4G16 mm²4G16 mm² (3×16 + 1G16)IEC 60228 Class 5 flexible Cu/SnCu21.88402.4130
CLEAN CABLE 4G35 mm²4G35 mm² (3×35 + 1G16)IEC 60228 Class 5 flexible Cu/SnCu28.61,6205.2172
CLEAN CABLE 3×70 + 3G16 mm²3 × 70 mm² + 3G16 mm²IEC 60228 Class 5 flexible Cu/SnCu38.43,18010.5230
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Custom core cross-sections, pair/fibre counts, armour grades and factory drum lengths available per CEI EN 60228 / ACS, KTW/W270, WRAS & DM 174 Potable Rubber.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
Conductor resistance, continuity & dimensional verification (CEI EN 60228 / ACS, KTW/W270, WRAS & DM 174 Potable Rubber)DC resistance at 20 °C / optical attenuation and outer diameter within CEI EN 60228 / ACS, KTW/W270, WRAS & DM 174 Potable Rubber tolerancesEvery manufactured drum length
High-voltage dielectric & insulation resistance test (CEI EN 60228 / ACS, KTW/W270, WRAS & DM 174 Potable Rubber)Zero dielectric breakdown and verified insulation resistance for 0.6/1 kV ratingEvery manufactured drum length
Sample tests
Hydrostatic pressure, water-blocking & mechanical endurance qualification (CEI EN 60228 / ACS, KTW/W270, WRAS & DM 174 Potable Rubber)Verified submersion integrity, tensile load and thermal stability across −40…+90 °CType qualification & periodic lot audit

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

ACS / KTW / WRAS / DM174 CompliantEN 10204 3.1 Factory Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

TEBAOFLEX CLEAN CABLE / CLEAN CABLE EMV ACS / KTW / WRAS / DM174 0.6/1 kV CE
Delivery form
Heavy-duty export fumigated wooden drums or steel subsea reels
Standard lengths
500 m, 1,000 m or custom continuous subsea/wellbore lengths
MOQ
100 m (standard configurations) · 500 m (custom builds)
Lead time
2–5 weeks ex-works
Incoterms
EXW, FCA, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-10-25
Updated
2026-10-25

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What governing standard and construction define CLEAN CABLE / CLEAN CABLE EMV (CLEAN CABLE & CLEAN CABLE EMV 0.6/1 kV 600m Potable-Water Pump Cable)?
CLEAN CABLE / CLEAN CABLE EMV (CLEAN CABLE & CLEAN CABLE EMV 0.6/1 kV 600m Potable-Water Pump Cable) is manufactured in accordance with CEI EN 60228 / ACS, KTW/W270, WRAS & DM 174 Potable Rubber for 0.6/1 kV service over -40 °C to +90 °C. Its 4-layer construction comprises class 5 bare copper conductors (4g1.5–50), high-insulation xlpe dielectric (>200 mω·km) and ral 5015 sky-blue cross-linked rubber sheath.
What is the minimum bending radius and operating temperature range for CLEAN CABLE / CLEAN CABLE EMV?
The minimum bending radius for CLEAN CABLE / CLEAN CABLE EMV is 6 × OD across its continuous operating temperature range of -40 °C to +90 °C, ensuring mechanical and dielectric reliability in subsea, marine and submersible service.
How are the concentric layers of CLEAN CABLE / CLEAN CABLE EMV arranged from inside to outside?
From inside to outside, the construction sequence is: (01) Class 5 Bare Copper Conductors (4G1.5–50) — CEI EN 60228 Class 5 flexible annealed bare copper conductors; (02) High-Insulation XLPE Dielectric (>200 MΩ·km) — Low-capacitance cross-linked polyethylene insulation (Brown, Black, Grey & G/Y); (03) Overall Tinned Copper Braid (EMV, ≥85%) — High-coverage tinned copper wire braid for VFD inverter EMC & bearing protection; (04) RAL 5015 Sky-Blue Cross-Linked Rubber Sheath — Food-grade rubber jacket (≤0.5% halogen; ACS, KTW/W270, WRAS & DM 174 certified).
What factory test certificates are supplied with CLEAN CABLE / CLEAN CABLE EMV?
Every production drum of CLEAN CABLE / CLEAN CABLE EMV undergoes routine conductor resistance/continuity, high-voltage dielectric and dimensional testing per CEI EN 60228 / ACS, KTW/W270, WRAS & DM 174 Potable Rubber, and is delivered with an EN 10204 3.1 factory test certificate.

Request a quote

Get an engineering quote for CLEAN CABLE / CLEAN CABLE EMV

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

CLEAN CABLE & CLEAN CABLE EMV 0.6/1 kV 600m Potable-Water Pump Cable

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote