BS 6883 / UKOOA offshore cableBS 6883 & UKOOA (GF / GH)150/250 V (300 V) & 600/1000 VEPR GP4 / SW4 LSZH · Cat A Flame

BS 6883 UIS / UCS Unarmoured Offshore Instrumentation CableBS 6883 & UKOOA Type UIS (IS+OS) & Type UCS (OS) EPR/SW4 LSZH offshore cable

Fixed offshore installation instrumentation cable built to BS 6883 and UKOOA (Type UCS Code GF and Type UIS Code GH) with Class 5 tinned copper conductors, +90 °C EPR GP4 insulation, Al/PET screen and heavy-duty SW4 oil-resistant LSZH elastomer sheath.

Flame-retardant
Oil-resistant
Low-EMC design
EMC screen
Order designation
BS6883-UIS 7P×0.75 (GH110)
Outer Ø ≈
16.2 mm
Copper weight
140 kg/km
Total weight ≈
365 kg/km
Min. bend R (fixed)
97 mm
All sizes (18)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
150/250 V
300 V class (600/1000 V option)
UKOOA types
UCS (GF) / UIS
UCS: Collective · UIS: Ind+Coll
Insulation
EPR GP4 (+90 °C)
cross-linked elastomer BS 7655
Outer sheath
SW4 LSZH (+90°C)
oil-resistant halogen-free
Flame test
IEC 60332-3-22
Category A bunched vertical
Temperature
−40 °C to +90 °C
fixed arctic & tropical offshore

Typical values for this cable type, based on BS 6883 / UKOOA (Codes GF & GH) / BS 7655 / IEC 60332-3-22 — confirmed in the datasheet and quotation for your order.

Application fit

Is BS 6883 UIS / UCS right for your machine?

Engineered for internal accommodation modules, control rooms, switchgear rooms and sheltered deck trays on fixed offshore oil & gas platforms, FPSOs and drilling rigs where steel/bronze wire braid armour (Type WBIS/WBCS) is not required.

Fixed installation

Suitable

Supple Class 5 tinned copper conductors and elastomeric EPR/SW4 compounds allow tight 6 × OD routing inside offshore modules and cabinets.

Offshore platform & shipboard deck trays

Suitable

Heavy-duty SW4 thermoset LSZH sheath resists North Sea salt spray, UV weathering, IRM 902/903 mineral oils and diesel fuel.

TBM gantry & advancing tunnel reel

Not suitable

Unarmoured UIS/UCS cable; for exposed open-deck mechanical hazards specify wire-braid armoured BS 6883 WBIS/WBCS.

RE-2Y(st)Y SWAY Armoured Cable

Energy chain / drag chain

Not suitable

Designed for fixed offshore module and shipboard installation, not continuous drag chains.

PUR Drag-Chain Control Cable
Typical machinesFixed Offshore Oil & Gas Production PlatformsFPSO, FSO & FLNG Topsides Control ModulesOffshore Living Quarters, CCR & Marshalling RoomsJack-Up & Semi-Submersible Drilling UnitsOffshore Wind HVDC/HVAC Converter Stations

Construction

Layer by layer

Shown: BS6883-UIS 7P×0.75 mm² (UKOOA Code GH110) with Class 5 tinned copper conductors, GP4 EPR insulation, individual & collective Al/PET screens with tinned copper drain wires and Grey (or Ex-i Blue) SW4 thermoset LSZH outer sheath.

1234
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1Class 5 flexible tinned annealed copper0.75 mm² (24/0.20 mm), 1.0 mm² (32/0.20 mm), 1.5 mm² (30/0.25 mm) or 2.5 mm² (50/0.25 mm) per BS EN 60228 (Class 2 optional)Tin coating prevents marine sulphide corrosion while Class 5 stranding withstands platform vibration
2Cross-linked EPR elastomer (Type GP4)Ethylene Propylene Rubber (GP4 to BS 7655-1.2) rated +90 °C continuous / +250 °C short-circuitThermoset cross-linked insulation will not melt or drip during fire exposure
3Type UCS (Collective) or Type UIS (Individual + Collective) screenAluminium/PET tape (≥ 100 % coverage) in contact with 0.5 mm² tinned copper drain wire; pair screens isolated by PET tape on Type UISSuppresses electrostatic and VFD interference across offshore topsides
4Cross-linked oil-resistant LSZH elastomer (Type SW4)Reduced-halogen / zero-halogen thermoset elastomeric compound (SW4 to BS 7655-2.6) in Grey or Blue (Ex-i)Passes IEC 60332-3-22 Cat A flame, IEC 60754 halogen-free and BS 7655 hot oil immersion tests

Type UCS (UKOOA Code GF — Collective Screen)

Unarmoured Collectively Screened pairs/triads with overall Al/PET foil + tinned copper drain wire

Type UIS (UKOOA Code GH — Ind. + Coll. Screen)

Unarmoured Individually & Collectively Screened pairs/triads eliminating inter-pair crosstalk

Ex-i Intrinsically Safe (Blue SW4 Sheath)

RAL 5015 Blue SW4 thermoset LSZH outer sheath for Zone 1 / Zone 2 Ex-i offshore loops

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on BS 6883 / UKOOA (Codes GF & GH) / BS 7655 / IEC 60332-3-22. Values for your order are confirmed in the datasheet and quotation.

Electrical

Voltage rating (U₀/U)
150/250 V (300 V class) standard · 600/1000 V heavy-duty option
Test voltage (core-to-core / screen)
1500 V AC rms for 5 min (150/250 V grade) · 3500 V AC (600/1000 V grade)
Max. conductor DC resistance @ 20 °C
26.7 (0.75) · 20.0 (1.0) · 13.7 (1.5) · 8.21 Ω/km (2.5 mm² Cl.5)
Max. mutual capacitance @ 1 kHz
≤ 200 nF/km (UCS) · ≤ 250 nF/km (UIS)
Max. L/R ratio (inductance / resistance)
≤ 25 µH/Ω (0.75 & 1.0 mm²) · ≤ 40 µH/Ω (1.5 mm²) · ≤ 60 µH/Ω (2.5 mm²)

Thermal

Continuous conductor temperature
+90 °C (short-circuit rating +250 °C for 5 s)
Ambient operating range
−40 °C to +90 °C (fixed) · −25 °C to +90 °C (installation)

Mechanical

Min. bending radius, fixed
6 × OD (unarmoured UIS / UCS elastomeric construction)
Tear & abrasion resistance
Heavy-duty cross-linked SW4 thermoset rubber jacket

Resistance

Bunched vertical flame test
IEC 60332-3-22 Category A (7 litres/m non-metallic volume, 40 min burner)
Halogen gas & smoke emission
IEC 60754-1 (HCl ≤ 0.5 %), IEC 60754-2 & IEC 61034-2 (≥ 60 % light)
Oil & fluid immersion
BS 7655-2.6 Type SW4 mineral oil, diesel & chemical resistance at +100 °C

Reference standards

Design & offshore code standards
BS 6883, UKOOA (Codes GF & GH), BS 7655-1.2 (GP4) & BS 7655-2.6 (SW4)
Classification society type approvals
Lloyd's Register (LR), DNV & ABS offshore unit rules compatible

Identification

Core identification
Pairs: Bk/Wh numbered · Triads: Bk/Wh/Rd numbered · Quads: Bk/Wh/Rd/Bu
Outer sheath colour
Grey (standard non-Ex-i) or Blue (Ex-i intrinsic safety)
Customs tariff (HS)
8544.49

Sizes

18 standard BS 6883 / UKOOA Type UIS & Type UCS offshore cable sizes

1, 2, 3, 7, 12 and 20 pairs/triads in 0.75, 1.0, 1.5 and 2.5 mm² with UKOOA GF (UCS) and GH (UIS) reference codes.

Dimensions, UKOOA codes & weights
Order designation (UKOOA)FormatScreen typeOuter Ø ≈
mm
Copper
kg/km
Weight ≈
kg/km
Min. bend R
fixed mm
Enquiry
0.75 mm² (24/0.20 mm) — L/R ≤ 25 µH/Ω · R₂₀ ≤ 26.7 Ω/km (UKOOA GF/GH)
BS6883-UCS 1P×0.75 (GF107)1×2×0.75 mm²UCS (OS)7.2197643
BS6883-UCS 1T×0.75 (GF132)1×3×0.75 mm²UCS (OS)7.7268846
BS6883-UCS 2P×0.75 (GF108)2×2×0.75 mm² (Quad)UCS (OS)8.63411252
BS6883-UCS 3P×0.75 (GF109)3×2×0.75 mm²UCS (OS)11.44817268
BS6883-UCS 7P×0.75 (GF110)7×2×0.75 mm²UCS (OS)14.810830589
BS6883-UCS 12P×0.75 (GF111)12×2×0.75 mm²UCS (OS)19.2182495115
BS6883-UCS 20P×0.75 (GF112)20×2×0.75 mm²UCS (OS)23.8302768143
BS6883-UIS 3P×0.75 (GH109)3×2×0.75 mm²UIS (IS+OS)12.26220273
BS6883-UIS 7P×0.75 (GH110)7×2×0.75 mm²UIS (IS+OS)16.214036597
BS6883-UIS 12P×0.75 (GH111)12×2×0.75 mm²UIS (IS+OS)21.0238590126
1.0 mm² (32/0.20 mm) — L/R ≤ 25 µH/Ω · R₂₀ ≤ 20.0 Ω/km (UKOOA GF/GH)
BS6883-UCS 1P×1.0 (GF114)1×2×1.0 mm²UCS (OS)7.6248646
BS6883-UIS 3P×1.0 (GH116)3×2×1.0 mm²UIS (IS+OS)13.07823678
BS6883-UIS 7P×1.0 (GH117)7×2×1.0 mm²UIS (IS+OS)17.2178428103
BS6883-UIS 12P×1.0 (GH118)12×2×1.0 mm²UIS (IS+OS)22.4302695134
1.5 mm² (30/0.25 mm) — L/R ≤ 40 µH/Ω · R₂₀ ≤ 13.7 Ω/km (UKOOA GF/GH)
BS6883-UCS 1P×1.5 (GF121)1×2×1.5 mm²UCS (OS)8.43410850
BS6883-UIS 3P×1.5 (GH123)3×2×1.5 mm²UIS (IS+OS)14.610830488
BS6883-UIS 7P×1.5 (GH124)7×2×1.5 mm²UIS (IS+OS)19.4248558116
2.5 mm² (50/0.25 mm) — L/R ≤ 60 µH/Ω · R₂₀ ≤ 8.21 Ω/km (UKOOA GF/GH)
BS6883-UCS 1P×2.5 (GF128)1×2×2.5 mm²UCS (OS)9.85314859
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • UKOOA First Letter 'G' = Grey outer sheath (standard); replace 'G' with 'B' (e.g. BF107 / BH110) for Blue Ex-i outer sheath.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
1500 V / 3500 V AC spark & 5-minute water-immersion voltage testNo breakdown during 5 min AC test in water bath per BS 6883Every manufactured drum
Sample tests
IEC 60332-3-22 Cat A flame, IEC 60754-1/2 halogen & BS 7655 SW4 oil testChar ≤ 2.5 m under Cat A 7 L/m flame; HCl ≤ 0.5 %; pass hot oil immersionPeriodic audit & type test

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

BS 6883 & UKOOA (Codes GF/GH/BF/BH) CompliantIEC 60332-3-22 Cat A, IEC 60754 & IEC 61034BS 7655-1.2 (GP4) & BS 7655-2.6 (SW4)

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

TEBAOFLEX BS 6883 <UIS/UCS> <size> 150/250V UKOOA <code > SW4 IEC 60332-3-22 CAT A CE
Delivery form
Non-returnable fumigated wooden drums
Standard lengths
500 m · 1000 m standard drums (cut lengths on request)
MOQ
500 m (stock sizes) · 1000 m (custom)
Lead time
2–4 weeks ex-works
Incoterms
EXW, FCA, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-10-20
Updated
2026-10-20

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What do the acronyms UCS (Code GF) and UIS (Code GH) mean in BS 6883 / UKOOA offshore cables?
'UCS' stands for Unarmoured Collectively Screened (UKOOA Code GF in Grey sheath, BF in Blue Ex-i sheath), which applies a single overall Al/PET foil screen and drain wire around all pairs. 'UIS' stands for Unarmoured Individually and Collectively Screened (UKOOA Code GH in Grey sheath, BH in Blue Ex-i sheath), which screens every individual pair/triad as well as the complete bundle.
How does BS 6883 differ from onshore BS 5308 or EN 50288-7 LSZH cables?
Onshore BS 5308 and RE-2X(st)H cables use thermoplastic LSZH outer sheaths rated to IEC 60332-3-24 (Category C) and are susceptible to swelling in hot hydrocarbons. BS 6883 uses cross-linked EPR (GP4) insulation and a heavy-duty thermoset elastomeric LSZH outer sheath (Type SW4 to BS 7655-2.6) that resists hot mineral oil, diesel and drilling fluids while passing the most stringent IEC 60332-3-22 Category A bunched flame test.
Why does BS 6883 use standard pair counts of 1, 2, 3, 7, 12, 20, 27 and 37 pairs instead of 4, 8, 16 and 24?
Under UKOOA and BS 6883 geometric lay-up rules, 1, 3, 7, 12, 20, 27 and 37 pairs form perfectly concentric circular layers (1, 3, 1+6, 3+9, 1+6+13, etc.), producing a tight, round cross-section that seals reliably inside offshore bulkhead transit frames and Ex-d/Ex-e compression glands.
How should the screen and drain wire of BS 6883 UIS / UCS be earthed in instrumentation and Ex-i loops?
To prevent circulating 50/60 Hz ground-loop currents from coupling into millivolt or 4–20 mA signals, the Al/PET screen and tinned copper drain wire of BS 6883 UIS / UCS should be bonded to the clean instrumentation earth bar at one end only (typically in the control/marshalling cabinet) and insulated against chassis contact at the field transmitter or junction box, in accordance with IEC 60079-14 and EN 50288-7.

Request a quote

Get an engineering quote for BS 6883 UIS / UCS

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

BS 6883 UIS / UCS Unarmoured Offshore Instrumentation Cable

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote