Fixed installation
Individually and/or collectively screened pairs, triads and quads reject electrostatic and electromagnetic interference.
Product
BFOU(i) S3/S7 & BFOU(c) S4/S8 250 V NEK 606 Fire-Resistant Offshore Instrumentation Cable (NEK TS 606 / IEC 60092-376) engineered for 150/250 V service across -40 to +90 °C (min. bend radius 8 × OD).
Typical values for this cable type, based on NEK TS 606 Code S3/S7/S103 & S4/S8/S104 / IEC 60092-376 / IEC 60331 — confirmed in the datasheet and quotation for your order.
Application fit
BFOU(i) S3/S7 & BFOU(c) S4/S8 250 V NEK 606 Fire-Resistant Offshore Instrumentation Cable (NEK TS 606 / IEC 60092-376) engineered for 150/250 V service across -40 to +90 °C (min. bend radius 8 × OD).
Individually and/or collectively screened pairs, triads and quads reject electrostatic and electromagnetic interference.
SHF1/SHF2 or IEEE 1580 Type P outer sheath resists drilling mud, hydrocarbons, salt spray and UV exposure.
Compact twisted pairs and numbered cores route cleanly into DCS/PLC cabinets, Ex-i barriers and bridge consoles.
Tinned copper, bronze or galvanized steel wire braid armour protects signal integrity in hazardous offshore zones.
Fixed shipboard and offshore instrumentation cable is not intended for high-speed crane festoon loops.
Use (N)3GRDC5G-J/O Festoon CableConstruction
Shown: BFOU(I) S3/S7 & BFOU(C) S4/S8 250 V (NEK TS 606 Code S3/S7/S103 & S4/S8/S104 / IEC 60092-376 / IEC 60331) featuring mica + epr twisted pairs (8×2×1.0 mm²), individual pair foil screen (bfou(i)) and blue ex-i / grey shf2-mud jacket (s3/s7) (5-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | Mica + EPR Twisted Pairs (8×2×1.0 mm²) | Tinned copper conductors with mica fire tape and Black/White EPR insulation |
| 2 | Individual Pair Foil Screen (BFOU(i)) | Color-coded/numbered Al/PET foil tape + tinned copper drain wire per pair |
| 3 | SHF2 Elastomeric Inner Bedding | Flame-retardant halogen-free thermoset inner sheath |
| 4 | Tinned Copper Braid Armour (TCWB) | High-coverage tinned copper wire braid screen and armour |
| 5 | Blue Ex-i / Grey SHF2-MUD Jacket (S3/S7) | Mud-resistant thermoset outer sheath (Blue for Intrinsically Safe circuits) |
Built to NEK TS 606 Code S3/S7/S103 & S4/S8/S104 / IEC 60092-376 / IEC 60331 with mica + epr twisted pairs (8×2×1.0 mm²) and blue ex-i / grey shf2-mud jacket (s3/s7)
Available in custom continuous shipboard/offshore drum lengths or with marine EMC cable glands
Supplied with EN 10204 3.1 routine dielectric, conductor resistance & flame/fire test report
Technical data
Sizes
Manufactured to NEK TS 606 Code S3/S7/S103 & S4/S8/S104 / IEC 60092-376 / IEC 60331 for shipboard, offshore platform, drilling rig and marine applications.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Tensile rating kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| BFOU(I) S3/S7 & BFOU(C) S4/S8 250 V Construction Schedule (−40…+90 °C) | |||||||
| BFOU(I) S3 2×2×0.75 mm² | 2 × 2 × 0.75 mm² (2Pr) | Stranded Cu/SnCu (IEC 60228 Class 2/5) | 11.4 | 195 | 1.2 | 70 | |
| BFOU(I) S3 4×2×1.0 mm² | 4 × 2 × 1.0 mm² (4Pr) | Stranded Cu/SnCu (IEC 60228 Class 2/5) | 15.6 | 365 | 2.4 | 95 | |
| BFOU(I) S3 8×2×1.5 mm² | 8 × 2 × 1.5 mm² (8Pr) | Stranded Cu/SnCu (IEC 60228 Class 2/5) | 22.8 | 760 | 4.8 | 140 | |
| Configuration | Max. DC R₂₀ / Atten. Ω/km or dB/km | Rating / Impedance | Operating temp. |
|---|---|---|---|
| 2 × 2 × 0.75 mm² (2Pr) | 26.00 | 150/250 V (≤60 nF/km) | −40…+90 °C |
| 4 × 2 × 1.0 mm² (4Pr) | 19.50 | 150/250 V (≤65 nF/km) | −40…+90 °C |
| 8 × 2 × 1.5 mm² (8Pr) | 13.30 | 150/250 V (≤75 nF/km) | −40…+90 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance, continuity & dimensional verification (NEK TS 606 Code S3/S7/S103 & S4/S8/S104 / IEC 60092-376 / IEC 60331) | DC resistance at 20 °C / optical attenuation and outer diameter within NEK TS 606 Code S3/S7/S103 & S4/S8/S104 / IEC 60092-376 / IEC 60331 tolerances | Every manufactured drum length |
| High-voltage dielectric & insulation resistance test (NEK TS 606 Code S3/S7/S103 & S4/S8/S104 / IEC 60092-376 / IEC 60331) | Zero dielectric breakdown and verified insulation resistance for 150/250 V rating | Every manufactured drum length |
| Sample tests | ||
| Flame, fire integrity, oil/mud & mechanical qualification (NEK TS 606 Code S3/S7/S103 & S4/S8/S104 / IEC 60092-376 / IEC 60331) | Verified flame/fire performance, fluid resistance and thermal stability across −40…+90 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.