ACIC 300 V Armored Interlocked Control & Instrumentation CableCSA C22.2 No. 239 / UL 13 · 300 V · -40 °C to +90 °C industrial ACIC INSTRUMENTATION

ACIC 300 V Armored Interlocked Control & Instrumentation Cable engineered to CSA C22.2 No. 239 / UL 13 for 300 V service across -40 °C to +90 °C, featuring stranded bare & tinned copper conductor and grey pvc outer jacket with minimum bending radius 12 × OD.

Approved
Low-EMC design
EMC screen
Flame-retardant
Order designation
ACIC INSTRUMENTATION 4×2×1.0
Outer Ø ≈
13.5 mm
Total weight ≈
264 kg/km
Min. bend R (fixed)
108 mm
Configuration
4×2×1.0 mm²
All sizes (12)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
300 V
Per CSA C22.2 No. 239 / UL 13
Operating temp.
−40…+90 °C
Continuous thermal rating
Min. bend radius
12 × OD
Installed / fixed routing
Conductor
bare & tinned
High-conductivity bare & tinned
Outer layer
Grey PVC outer
Extruded Grey PVC outer jacket
Standard
CSA C22.2 No.
CSA C22.2 No. 239 / UL 13

Typical values for this cable type, based on CSA C22.2 No. 239 / UL 13 — confirmed in the datasheet and quotation for your order.

Application fit

Is ACIC 300V right for your machine?

ACIC 300 V Armored Interlocked Control & Instrumentation Cable engineered to CSA C22.2 No. 239 / UL 13 for 300 V service across -40 °C to +90 °C, featuring stranded bare & tinned copper conductor and grey pvc outer jacket with minimum bending radius 12 × OD.

Fixed installation

Suitable

Engineered and verified for fixed service in accordance with CSA C22.2 No. 239 / UL 13.

Switchgear & control cabinet wiring

Suitable

Suitable for switchgear, control panels and equipment terminations within 12 × OD bend radius.

TBM gantry & advancing tunnel reel

With conditions

Use mechanical conduit or armoured protection where exposed to rock fall or crushing loads.

Motorised monospiral reel

Not suitable

Not designed for high-speed monospiral crane reeling; select a dedicated reeling cable.

NSHTOU Reeling Cable
Typical machinesOil & Gas CableRefinery & Petrochemical Process UnitsLNG Terminals & Tank FarmsOnshore & Offshore Oil & Gas FacilitiesChemical & Hydrocarbon Processing PlantsSurface & Underground Mining Substations

Construction

Layer by layer

Shown: ACIC INSTRUMENTATION (CSA C22.2 No. 239 / UL 13) with stranded bare & tinned copper conductor, individual al/pet screen and grey pvc outer jacket (8-layer construction).

12345678
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1Stranded bare & tinned copper conductorHigh-conductivity bare & tinned copper conductor per CSA C22.2 No. 239 / UL 13CSA C22.2 No. 239 / UL 13
2Individual Al/PET screenIndividual Al/PET screen metallic electromagnetic screen (individual core / group layer)CSA C22.2 No. 239 / UL 13
3XLPE core insulationExtruded XLPE dielectric (individual core / group layer)CSA C22.2 No. 239 / UL 13
4Polypropylene fillers and polyester binderHelically applied polypropylene fillers and polyester binderCSA C22.2 No. 239 / UL 13
5Overall Al/PET screenOverall Al/PET screen metallic electromagnetic screen (lapped tape)CSA C22.2 No. 239 / UL 13
6Black PVC inner jacketExtruded Black PVC inner jacket protective layer (continuous layer)CSA C22.2 No. 239 / UL 13
7Aluminium interlocked armourAluminium interlocked armour mechanical protection (interlocked armour)CSA C22.2 No. 239 / UL 13
8Grey PVC outer jacketExtruded Grey PVC outer jacket protective layer (continuous layer)CSA C22.2 No. 239 / UL 13

ACIC INSTRUMENTATION — Standard Execution

Built to CSA C22.2 No. 239 / UL 13 with stranded bare & tinned copper conductor and grey pvc outer jacket

ACIC INSTRUMENTATION — Custom Cross-Sections

Full range of metric mm² and AWG/kcmil conductor sizes per CSA C22.2 No. 239 / UL 13

ACIC INSTRUMENTATION — Export Drum Supply

Supplied with EN 10204 3.1 routine dielectric & conductor resistance test certificate

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on CSA C22.2 No. 239 / UL 13. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage / duty
300 V (CSA C22.2 No. 239 / UL 13)
Conductor construction
Stranded bare & tinned copper conductor — High-conductivity bare & tinned copper conductor per CSA C22.2 No. 239 / UL 13
Primary insulation / dielectric
Individual Al/PET screen — Individual Al/PET screen metallic electromagnetic screen (individual core / group layer)

Thermal

Continuous operating temperature
−40…+90 °C per CSA C22.2 No. 239 / UL 13
Short-circuit / peak thermal limit
+160 °C to +250 °C (5 s adiabatic limit depending on dielectric class)
Minimum installation temperature
−5 °C (thermoplastic) / −25 °C (cross-linked or elastomer) / −40 °C (metallic)

Mechanical

Outer protection / covering
Grey PVC outer jacket — Extruded Grey PVC outer jacket protective layer (continuous layer)
Minimum bending radius
12 × OD (installed / static routing)
Layer count & geometry
8 concentric/structural layers verified by cross-section inspection

Resistance

Environmental & chemical durability
Engineered for industrial service in accordance with CSA C22.2 No. 239 / UL 13
RoHS & REACH compliance
RoHS 2 (2011/65/EU + 2015/863) & REACH SVHC compliant

Reference standards

Governing product standard
CSA C22.2 No. 239 / UL 13
Quality management & inspection
ISO 9001:2015 & EN 10204 3.1 factory routine inspection

Identification

Model designation
ACIC INSTRUMENTATION
Customs tariff (HS)
8544.49 / 8544.60 / 7614.10

Sizes

12 standard ACIC INSTRUMENTATION cable configurations

Manufactured to CSA C22.2 No. 239 / UL 13 in single-pair, multi-pair and multi-unit constructions.

Dimensions, construction & weights
Order designationConfigurationOuter Ø ≈
mm
Weight ≈
kg/km
Min. bend R
fixed mm
Enquiry
ACIC INSTRUMENTATION Standard Construction Schedule (300 V · −40…+90 °C)
ACIC INSTRUMENTATION 1×2×0.51×2×0.5 mm²6.45852
ACIC INSTRUMENTATION 2×2×0.52×2×0.5 mm²9.211274
ACIC INSTRUMENTATION 4×2×0.54×2×0.5 mm²11.417692
ACIC INSTRUMENTATION 8×2×0.58×2×0.5 mm²14.8295118
ACIC INSTRUMENTATION 12×2×0.512×2×0.5 mm²17.6420141
ACIC INSTRUMENTATION 1×2×1.01×2×1.0 mm²7.68661
ACIC INSTRUMENTATION 2×2×1.02×2×1.0 mm²11.016888
ACIC INSTRUMENTATION 4×2×1.04×2×1.0 mm²13.5264108
ACIC INSTRUMENTATION 8×2×1.08×2×1.0 mm²17.9465143
ACIC INSTRUMENTATION 1×2×1.51×2×1.5 mm²8.511468
ACIC INSTRUMENTATION 4×2×1.54×2×1.5 mm²15.2348122
ACIC INSTRUMENTATION 12×2×1.512×2×1.5 mm²23.4860187
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Additional pair/triad/quad counts (up to 48 pairs) and blue Ex-i intrinsically safe outer sheaths available per CSA C22.2 No. 239 / UL 13.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
Conductor DC resistance & dimensional verification (CSA C22.2 No. 239 / UL 13)DC resistance at 20 °C and geometry within CSA C22.2 No. 239 / UL 13 class limitsEvery manufactured drum / spool
Routine dielectric / spark / structural integrity test (CSA C22.2 No. 239 / UL 13)Zero breakdown or structural defect over full production lengthEvery manufactured drum / spool
Sample tests
Thermal aging, mechanical & material qualification (CSA C22.2 No. 239 / UL 13)Full compliance with CSA C22.2 No. 239 / UL 13 across −40…+90 °CType qualification & periodic sample audit

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

CSA C22.2 No. 239 CompliantEN 10204 3.1 Routine Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

TEBAOFLEX ACIC INSTRUMENTATION <size> CSA C22.2 No. 239 300 V CE
Delivery form
Non-returnable fumigated wooden drums or precision DIN spools
Standard lengths
500 m · 1000 m · 2000 m drums (custom cut lengths on request)
MOQ
500 m (stock sizes) · 1000 m (custom production)
Lead time
2–4 weeks ex-works
Incoterms
EXW, FCA, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-10-21
Updated
2026-10-21

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What governing standard and construction define ACIC INSTRUMENTATION (ACIC 300 V Armored Interlocked Control & Instrumentation Cable)?
ACIC INSTRUMENTATION (ACIC 300 V Armored Interlocked Control & Instrumentation Cable) is manufactured in accordance with CSA C22.2 No. 239 / UL 13 for 300 V service over -40 °C to +90 °C. Its 8-layer construction comprises stranded bare & tinned copper conductor, individual al/pet screen, xlpe core insulation, polypropylene fillers and polyester binder, overall al/pet screen, black pvc inner jacket, aluminium interlocked armour, grey pvc outer jacket.
What is the minimum bending radius and installation temperature for ACIC INSTRUMENTATION?
The minimum installed bending radius for ACIC INSTRUMENTATION is 12 × OD across its continuous operating temperature range of -40 °C to +90 °C, ensuring mechanical and dielectric stability without conductor or insulation strain.
How are the concentric layers of ACIC INSTRUMENTATION arranged from inside to outside?
From inside to outside, the construction sequence is: (01) Stranded bare & tinned copper conductor (High-conductivity bare & tinned copper conductor per CSA C22.2 No. 239 / UL 13); (02) Individual Al/PET screen (Individual Al/PET screen metallic electromagnetic screen (individual core / group layer)); (03) XLPE core insulation (Extruded XLPE dielectric (individual core / group layer)); (04) Polypropylene fillers and polyester binder (Helically applied polypropylene fillers and polyester binder); (05) Overall Al/PET screen (Overall Al/PET screen metallic electromagnetic screen (lapped tape)); (06) Black PVC inner jacket (Extruded Black PVC inner jacket protective layer (continuous layer)); (07) Aluminium interlocked armour (Aluminium interlocked armour mechanical protection (interlocked armour)); (08) Grey PVC outer jacket (Extruded Grey PVC outer jacket protective layer (continuous layer)).
What factory test certificates are supplied with ACIC INSTRUMENTATION?
Every production drum or spool of ACIC INSTRUMENTATION undergoes routine conductor DC resistance, dimensional and dielectric/integrity testing per CSA C22.2 No. 239 / UL 13, and is delivered with an EN 10204 3.1 factory test certificate.

Request a quote

Get an engineering quote for ACIC 300V

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

ACIC 300 V Armored Interlocked Control & Instrumentation Cable

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote