Immersion & wet locations
Hydrolysis-resistant polyurethane (PUR) or HDPE jacket and water-blocked core withstand continuous deepwater hydrostatic immersion.
Product
A216375 .375-Inch (9.53 mm) 14,600 lbs Double-Armoured Electromechanical Winch Cable featuring multi-core stranded copper conductors and double contra-helical steel armour (.375") (UNOLS / .375 EM Winch, 600 V, -40 to +85 °C).
Typical values for this cable type, based on Hydrographic .375-Inch (9.53 mm) Torque-Balanced Double-Armoured EM Winch Specification — confirmed in the datasheet and quotation for your order.
Application fit
A216375 .375-Inch (9.53 mm) 14,600 lbs Double-Armoured Electromechanical Winch Cable featuring multi-core stranded copper conductors and double contra-helical steel armour (.375") (UNOLS / .375 EM Winch, 600 V, -40 to +85 °C).
Hydrolysis-resistant polyurethane (PUR) or HDPE jacket and water-blocked core withstand continuous deepwater hydrostatic immersion.
Torque-balanced contra-helical steel wire armour or high-modulus aramid strength member supports dynamic winch deployment without hockling
Abrasion-resistant outer sheath and high working-load strength elements handle dynamic marine towing, buoy mooring and ROV excursion.
UV-stabilised, oil- and seawater-resistant construction withstands A-frame sheaves, traction winches and open research-vessel decks.
Subsea umbilical, ROV tether and towed array cables are not designed for indoor factory automation drag chains.
Use M23 Servo AssemblyConstruction
Shown: A216375 .375 EM (Hydrographic .375-Inch (9.53 mm) Torque-Balanced Double-Armoured EM Winch Specification) featuring multi-core stranded copper conductors, polyolefin core insulation and double contra-helical steel armour (.375") (3-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | Multi-Core Stranded Copper Conductors | Seven stranded copper conductors for hydrographic power & telemetry |
| 2 | Polyolefin Core Insulation | High-dielectric polyolefin insulation |
| 3 | Double Contra-Helical Steel Armour (.375 | Two contra-helical galvanized steel wire layers (Ø 9.53 mm, 14,600 lbs) |
Built to Hydrographic .375-Inch (9.53 mm) Torque-Balanced Double-Armoured EM Winch Specification with multi-core stranded copper conductors and double contra-helical steel armour (.375")
Available in custom continuous subsea winch, tow or seabed lengths with water-blocked terminations
Supplied with EN 10204 3.1 routine dielectric, optical OTDR / DC resistance & tensile test report
Technical data
Sizes
Manufactured to Hydrographic .375-Inch (9.53 mm) Torque-Balanced Double-Armoured EM Winch Specification for subsea, oceanographic, ROV, seismic and offshore applications.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Breaking / tensile kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| A216375 .375 EM Construction Schedule (−40…+85 °C) | |||||||
| A216375 .375 EM Type I | Standard oceanographic / offshore build | Stranded SnCu / Double Steel or UHMWPE | 8.2 | 265 | 54.3 | 125 | |
| A216375 .375 EM Type II | Medium-duty deepwater / offshore build | Stranded SnCu / Double Steel or UHMWPE | 9.5 | 355 | 64.9 | 145 | |
| A216375 .375 EM Type III | Heavy-duty deep-tow / offshore build | Stranded SnCu / Double Steel or UHMWPE | 10.5 | 440 | 79.2 | 160 | |
| Configuration | Max. DC R₂₀ / Atten. Ω/km or dB/km | Rating / Impedance | Operating temp. |
|---|---|---|---|
| Standard oceanographic / offshore build | 11.50 | 600 V (Std Duty) | −40…+85 °C |
| Medium-duty deepwater / offshore build | 8.20 | 600 V (Med Duty) | −40…+85 °C |
| Heavy-duty deep-tow / offshore build | 6.50 | 600 V (Heavy Duty) | −40…+85 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance, optical OTDR continuity & dimensional verification (Hydrographic .375-Inch (9.53 mm) Torque-Balanced Double-Armoured EM Winch Specification) | DC resistance at 20 °C / optical attenuation and outer diameter within Hydrographic .375-Inch (9.53 mm) Torque-Balanced Double-Armoured EM Winch Specification tolerances | Every manufactured drum length |
| High-voltage dielectric & insulation resistance test (Hydrographic .375-Inch (9.53 mm) Torque-Balanced Double-Armoured EM Winch Specification) | Zero dielectric breakdown and verified insulation resistance for 600 V rating | Every manufactured drum length |
| Sample tests | ||
| Hydrostatic pressure, tensile breaking load & water-blocking qualification (Hydrographic .375-Inch (9.53 mm) Torque-Balanced Double-Armoured EM Winch Specification) | Verified subsea pressure integrity, torque-balanced tensile performance and thermal stability across −40…+85 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.