VFD inverter to AC motor screened feeder
Symmetrical low-impedance EMC design for PWM inverter motor and pump feeders per UL 1072 / IEEE 1580 / CSA C68.10.
Product
Engineered for underground mining, open-cast excavation, shaft infrastructure and heavy industrial service per UL 1072 / IEEE 1580 / CSA C68.10 across -40 to +90 °C.
Typical values for this cable type, based on UL 1072 / IEEE 1580 / CSA C68.10 — confirmed in the datasheet and quotation for your order.
Application fit
Engineered for underground mining, open-cast excavation, shaft infrastructure and heavy industrial service per UL 1072 / IEEE 1580 / CSA C68.10 across -40 to +90 °C.
Symmetrical low-impedance EMC design for PWM inverter motor and pump feeders per UL 1072 / IEEE 1580 / CSA C68.10.
Suitable for mining processing plants, slurry pumps and underground VFD drives (-40 to +90 °C).
Approved for cable tray, rack, conduit and trailing feeder routing within 8 × OD.
Not optimized for high-speed overhead crane C-track festoon loops; select a dedicated festoon cable.
NGFLGÖU Flat Rubber Festoon CableConstruction
Shown: 37-105VFD (MMV-VFD) (UL 1072 / IEEE 1580 / CSA C68.10) featuring mv phase conductors (3×2/0 awg), individual phase shield and arctic-grade outer jacket (-j) (5-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | MV Phase Conductors (3×2/0 AWG) | Extra-flexible tinned copper + semicon shield + 133% 90 °C EPR insulation |
| 2 | Individual Phase Shield | Strippable semicon layer + composite nylon & tinned copper braid (≥60%) |
| 3 | Symmetrical Grounds (3×8 AWG XLPO) | Three green crosslinked polyolefin (XLPO) insulated flexible tinned copper grounds |
| 4 | Isolation Jacket & Overall EMI Armor | Black XLPO inner jacket + tinned copper braid armor + 100% Al/PET tape |
| 5 | Arctic-Grade Outer Jacket (-J) | Flame-retardant, oil- and sunlight-resistant thermosetting outer jacket |
Built to UL 1072 / IEEE 1580 / CSA C68.10 with mv phase conductors (3×2/0 awg) and arctic-grade outer jacket (-j)
Available in custom shaft/roadway drum lengths or pre-terminated assemblies
Supplied with EN 10204 3.1 routine dielectric, resistance & flame test report
Technical data
Sizes
Manufactured to UL 1072 / IEEE 1580 / CSA C68.10 for underground mining, open-cast excavation, shaft and heavy industrial systems.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Tensile rating kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| 37-105VFD (MMV-VFD) Construction Schedule (-40 to +90 °C) | |||||||
| 37-105VFD 8 kV 3×1 AWG + 3×8 AWG(G) | 3×1 AWG + 3×8 AWG (G) | Extra-flex tinned Cu | 53.8 | 4,120 | 19.0 | 430 | |
| 37-105VFD 8 kV 3×2/0 AWG + 3×8 AWG(G) | 3×2/0 AWG + 3×8 AWG (G) | Extra-flex tinned Cu | 59.4 | 5,360 | 26.8 | 475 | |
| 37-105VFD 15 kV 3×4/0 AWG + 3×6 AWG(G) | 3×4/0 AWG + 3×6 AWG (G) | Extra-flex tinned Cu | 71.2 | 7,890 | 42.0 | 570 | |
| Configuration | Max. DC R₂₀ / Atten. Ω/km or dB/km | Rating / Impedance | Operating temp. |
|---|---|---|---|
| 3×1 AWG + 3×8 AWG (8 kV) | 0.43 | 8 kV 133% (195 A) | -40 to +90 °C |
| 3×2/0 AWG + 3×8 AWG (8 kV) | 0.27 | 8 kV 133% (260 A) | -40 to +90 °C |
| 3×4/0 AWG + 3×6 AWG (15 kV) | 0.17 | 15 kV 133% (345 A) | -40 to +90 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance, continuity & dimensional verification (UL 1072 / IEEE 1580 / CSA C68.10) | DC resistance at 20 °C / optical attenuation and outer diameter within UL 1072 / IEEE 1580 / CSA C68.10 tolerances | Every manufactured drum length |
| High-voltage dielectric & insulation resistance test (UL 1072 / IEEE 1580 / CSA C68.10) | Zero dielectric breakdown and verified insulation resistance over full production length | Every manufactured drum length |
| Sample tests | ||
| Flame propagation, mechanical crush & thermal ageing qualification (UL 1072 / IEEE 1580 / CSA C68.10) | Verified flame retardancy, mechanical integrity and thermal endurance across -40 to +90 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.