VFD inverter to AC motor screened feeder
3+3 green LSHF-XLPO grounds plus 100% Al/PET and TCWB protect shipboard navigation from VFD EMI.
Product
Low-smoke halogen-free (LSHF) 2,000 V symmetrical marine VFD cable built to IEEE 1580 Type P and IEC 60092-353 with flexible tinned copper, 90 °C LSHF-XLPO insulation, Al/PET plus TCWB shield, and thermoset SHF2 sheath.
Typical values for this cable type, based on IEEE 1580 Type P · IEC 60092-353 LSHF · UL 1309 · IEC 60754 — confirmed in the datasheet and quotation for your order.
Application fit
Low-smoke halogen-free (LSHF) 2,000 V symmetrical marine VFD cable built to IEEE 1580 Type P and IEC 60092-353 with flexible tinned copper, 90 °C LSHF-XLPO insulation, Al/PET plus TCWB shield, and thermoset SHF2 sheath.
3+3 green LSHF-XLPO grounds plus 100% Al/PET and TCWB protect shipboard navigation from VFD EMI.
Zero-halogen SHF2 sheath (IEC 60754 / IEC 61034 ≥ 60%) keeps enclosed engine & switchgear rooms safe.
Thermoset SHF2 resists oil, abrasion, and −40 °C cold on offshore platforms and passenger ships.
Extra-flexible tinned copper bends down to 6 × OD for tight marine bulkhead and propulsion pulls.
Built for fixed shipboard cableways rather than continuous dynamic energy-chain flexing.
Use PUR-C-HF EMCNot rated for permanent underwater submersion; choose a clean-water EPDM submersible VFD cable.
Use EMC-VFD Clean-Water EPDMConstruction
Shown: 37-103VFD 2 kV LSHF 3×6 AWG + 3×12 AWG — flexible tinned copper phases and three green LSHF-XLPO grounds inside Al/PET foil, tinned Cu braid, and thermoset SHF2 sheath.
| # | Layer | Material & reference |
|---|---|---|
| 1 | Conductor | Extra-flexible stranded tinned annealed copperIEEE 1580 Table 11 / IEC 60228 |
| 2 | Insulation & core ID | 90 °C low-smoke halogen-free cross-linked polyolefin (LSHF XLPO)Natural numbered phases + 3 × green LSHF grounds |
| 3 | Core wrap | Halogen-free polyester core binder tapeZero-halogen assembly separator |
| 4 | Foil EMI shield | Aluminium/polyester foil shield (100% coverage)High-frequency electrostatic shield |
| 5 | Braid EMI shield | Overall tinned copper wire braid EMI shieldLow-impedance EMC shielding |
| 6 | Outer sheath (SHF2) | Black low-smoke halogen-free thermoset SHF2 outer sheathIEC 60092-360 SHF2 / IEC 60754 |
Three LSHF-XLPO phase cores + three green LSHF grounds under Al/PET foil + TCWB and thermoset SHF2 jacket (14 AWG–535 kcmil).
Technical data
Sizes
| Phase + 3× Ground (AWG) | Outer Ø ≈ mm | Max. R20 Ω/km | Copper index kg/km | Weight ≈ kg/km | Min. bend R 6×D mm |
|---|---|---|---|---|---|
| 3×14 AWG + 3×18 AWG | 16.1 | 9.070 | 136 | 371 | 97 |
| 3×12 AWG + 3×16 AWG | 17.2 | 5.710 | 187 | 465 | 103 |
| 3×10 AWG + 3×14 AWG | 18.6 | 3.590 | 267 | 606 | 112 |
| 3×8 AWG + 3×12 AWG | 21.5 | 2.260 | 396 | 861 | 129 |
| 3×6 AWG + 3×12 AWG | 23.7 | 1.420 | 539 | 1,121 | 142 |
| 3×4 AWG + 3×12 AWG | 27.5 | 0.892 | 769 | 1,566 | 165 |
| 3×2 AWG + 3×10 AWG | 32.0 | 0.561 | 1,179 | 2,299 | 192 |
| 3×1 AWG + 3×8 AWG | 34.1 | 0.445 | 1,513 | 2,838 | 205 |
| 3×1/0 AWG + 3×8 AWG | 36.5 | 0.353 | 1,826 | 3,371 | 219 |
| 3×2/0 AWG + 3×6 AWG | 39.1 | 0.280 | 2,352 | 4,202 | 235 |
| 3×4/0 AWG + 3×4 AWG | 46.1 | 0.176 | 3,686 | 6,383 | 277 |
| 3×262 kcmil + 3×4 AWG | 51.1 | 0.143 | 4,406 | 7,683 | 307 |
| 3×373 kcmil + 3×2 AWG | 57.6 | 0.101 | 6,312 | 10,690 | 346 |
| 3×535 kcmil + 3×1 AWG | 67.9 | 0.071 | 8,843 | 14,948 | 407 |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| AC high-voltage dielectric test | Per UL 1309 / IEC 60092-353 2 kV rating | Every manufactured reel |
| Conductor DC resistance check | Per IEEE 1580 Table 11 tinned copper | Every reel length |
| Sample tests | ||
| Zero-halogen & smoke density | IEC 60754-1/2 & IEC 61034-2 (≥ 60%) | Type approval |
| Bunched vertical flame test | IEC 60332-3-22 Cat A / IEEE 1202 | Type approval |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.