37-103VFD 2 kV LSHF Marine VFD CableHalogen-free SHF2 IEEE 1580 / IEC 60092-353 2 kV VFD cable

Low-smoke halogen-free (LSHF) 2,000 V symmetrical marine VFD cable built to IEEE 1580 Type P and IEC 60092-353 with flexible tinned copper, 90 °C LSHF-XLPO insulation, Al/PET plus TCWB shield, and thermoset SHF2 sheath.

Low-EMC design
EMC screen
Ozone, UV & moisture
Flame-retardant
Order designation
37-103VFD LSHF 3×6 AWG + 3×12 AWG
Outer Ø
23.7 mm
Max. R20
1.420 Ω/km
Weight
1,121 kg/km
Min. bend R
142 mm
All sizes (14)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
2,000 V (2 kV)
90 °C LSHF IEEE 1580 / IEC 60092-353
Halogen-free
Zero halogen
Zero halogen SHF2 · low smoke
EMC screening
Al/PET + TCWB
100% foil + overall tinned Cu braid
Conductor temp.
+90 °C max.
LSHF cross-linked polyolefin (XLPO)
Min. bend radius
6 × OD
Flexible unarmored marine routing
Size range
14 AWG–535 MCM
3+3 symmetrical flex tinned Cu

Typical values for this cable type, based on IEEE 1580 Type P · IEC 60092-353 LSHF · UL 1309 · IEC 60754 — confirmed in the datasheet and quotation for your order.

Application fit

Is 37-103VFD 2kV LSHF right for your machine?

Low-smoke halogen-free (LSHF) 2,000 V symmetrical marine VFD cable built to IEEE 1580 Type P and IEC 60092-353 with flexible tinned copper, 90 °C LSHF-XLPO insulation, Al/PET plus TCWB shield, and thermoset SHF2 sheath.

VFD inverter to AC motor screened feeder

Suitable

3+3 green LSHF-XLPO grounds plus 100% Al/PET and TCWB protect shipboard navigation from VFD EMI.

Enclosed LSHF shipboard room

Suitable

Zero-halogen SHF2 sheath (IEC 60754 / IEC 61034 ≥ 60%) keeps enclosed engine & switchgear rooms safe.

Offshore platform & shipboard deck trays

Suitable

Thermoset SHF2 resists oil, abrasion, and −40 °C cold on offshore platforms and passenger ships.

Motor stator, traction & converter leads

Suitable

Extra-flexible tinned copper bends down to 6 × OD for tight marine bulkhead and propulsion pulls.

Energy chain / drag chain

Not suitable

Built for fixed shipboard cableways rather than continuous dynamic energy-chain flexing.

Use PUR-C-HF EMC

Immersion & wet locations

Not suitable

Not rated for permanent underwater submersion; choose a clean-water EPDM submersible VFD cable.

Use EMC-VFD Clean-Water EPDM
Typical machinesMarine & Offshore CableCruise, naval & commercial vesselsOffshore accommodation & switchgear roomsMarine propulsion & HVAC drivesEnclosed offshore platforms & FPSOsZero-halogen coastal infrastructure

Construction

Layer by layer

Shown: 37-103VFD 2 kV LSHF 3×6 AWG + 3×12 AWG — flexible tinned copper phases and three green LSHF-XLPO grounds inside Al/PET foil, tinned Cu braid, and thermoset SHF2 sheath.

123456
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1ConductorExtra-flexible stranded tinned annealed copperIEEE 1580 Table 11 / IEC 60228
2Insulation & core ID90 °C low-smoke halogen-free cross-linked polyolefin (LSHF XLPO)Natural numbered phases + 3 × green LSHF grounds
3Core wrapHalogen-free polyester core binder tapeZero-halogen assembly separator
4Foil EMI shieldAluminium/polyester foil shield (100% coverage)High-frequency electrostatic shield
5Braid EMI shieldOverall tinned copper wire braid EMI shieldLow-impedance EMC shielding
6Outer sheath (SHF2)Black low-smoke halogen-free thermoset SHF2 outer sheathIEC 60092-360 SHF2 / IEC 60754

37-103VFD 2 kV LSHF (SHF2)

Three LSHF-XLPO phase cores + three green LSHF grounds under Al/PET foil + TCWB and thermoset SHF2 jacket (14 AWG–535 kcmil).

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on IEEE 1580 Type P · IEC 60092-353 LSHF · UL 1309 · IEC 60754. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage
2,000 V (2 kV) AC
Conductor class
IEEE 1580 Table 11 flex tinned Cu
Dual EMI shield
100% Al/PET foil + overall TCWB

Thermal

Max. conductor temp.
+90 °C continuous (LSHF XLPO)
Cold bend / impact
−40 °C bend / −35 °C impact
Min. bending radius
6 × OD (unarmored flexible)

Resistance

Flame test
IEC 60332-3-22 Cat A / IEEE 1202
Acid gas / halogens
Halogen-free per IEC 60754-1 & -2
Smoke emission
Low smoke ≥ 60% transmittance
Sheath compound
Black thermoset LSHF (SHF2)

Sizes

3+3 Symmetrical (LSHF SHF2)
Phase + 3×
Ground (AWG)
Outer Ø ≈
mm
Max. R20
Ω/km
Copper index
kg/km
Weight ≈
kg/km
Min. bend R
6×D mm
3×14 AWG + 3×18 AWG16.19.07013637197
3×12 AWG + 3×16 AWG17.25.710187465103
3×10 AWG + 3×14 AWG18.63.590267606112
3×8 AWG + 3×12 AWG21.52.260396861129
3×6 AWG + 3×12 AWG23.71.4205391,121142
3×4 AWG + 3×12 AWG27.50.8927691,566165
3×2 AWG + 3×10 AWG32.00.5611,1792,299192
3×1 AWG + 3×8 AWG34.10.4451,5132,838205
3×1/0 AWG + 3×8 AWG36.50.3531,8263,371219
3×2/0 AWG + 3×6 AWG39.10.2802,3524,202235
3×4/0 AWG + 3×4 AWG46.10.1763,6866,383277
3×262 kcmil + 3×4 AWG51.10.1434,4067,683307
3×373 kcmil + 3×2 AWG57.60.1016,31210,690346
3×535 kcmil + 3×1 AWG67.90.0718,84314,948407
  • Conductor max. DC resistance R20 follows IEEE 1580 Table 11 / ASTM B172 flexible tinned copper at 20 °C.
  • All insulation, binder tape, and SHF2 outer sheath materials are halogen-free per IEC 60754-1/2 and low-smoke per IEC 61034-2.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
AC high-voltage dielectric testPer UL 1309 / IEC 60092-353 2 kV ratingEvery manufactured reel
Conductor DC resistance checkPer IEEE 1580 Table 11 tinned copperEvery reel length
Sample tests
Zero-halogen & smoke densityIEC 60754-1/2 & IEC 61034-2 (≥ 60%)Type approval
Bunched vertical flame testIEC 60332-3-22 Cat A / IEEE 1202Type approval

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

IEEE 1580 Type P · UL 1309 Marine (2 kV LSHF)IEC 60092-353 & IEC 60092-360 SHF2 ThermosetIEC 60754-1/2 Halogen-Free · IEC 61034-2 Low Smoke

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

37-103VFD 2kV LSHF TEBAOFLEX.COM IEEE 1580 IEC 60092-353 SHF2 [Size]
Delivery form
Cut-to-length or wooden export reels
Standard drum lengths
305 m (1,000 ft) · 500 m · 1,000 m
MOQ
100 m (stock sizes) · 500 m (production)
Lead time
2–3 weeks ex-works
Incoterms
EXW, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-11-20
Updated
2026-11-20

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

How does 37-103VFD 2kV LSHF differ from standard 37-102VFD?
37-103VFD replaces chlorinated CPE with a halogen-free thermoset SHF2 sheath and 90 °C LSHF-XLPO insulation, meeting IEC 60754 zero-halogen and IEC 61034 low-smoke requirements for passenger vessels and enclosed offshore modules.
Why specify thermoset SHF2 instead of thermoplastic SHF1 on marine VFD cables?
Thermoset SHF2 offers far superior resistance to oils, abrasion, cold bending (−40 °C), and thermal deformation than thermoplastic SHF1 while maintaining zero-halogen fire safety.
Does 37-103VFD 2kV LSHF maintain the same dual EMI shield?
Yes. It retains both the 100% Al/PET foil shield and overall tinned copper wire braid plus three symmetrical green LSHF-insulated grounds to protect shipboard navigation and automation systems from VFD noise.
How should the EMC shield and symmetrical grounds of 37-103VFD 2kV LSHF be terminated?
Bond the metallic EMC shield circumferentially (360°) at both the inverter cabinet and motor terminal box using EMC cable glands or constant-force springs, and connect all protective ground conductors cleanly to the earth busbar.
Which technical documents are available?
Reference files are provided for project screening. Final parameters and the applicable document package are confirmed during quotation.

Request a quote

Get an engineering quote for 37-103VFD 2kV LSHF

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

37-103VFD 2 kV LSHF Marine VFD Cable

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote