VFD inverter to AC motor screened feeder
Symmetrical 3+3E split-earth geometry and dual 100% foil + copper braid screen contain PWM inverter common-mode currents.
Product
M2XCH-EMC & LKSM-EMC 0.6/1–1.8/3 kV Dual-Screened Shipboard Propulsion & VFD Cable (IEC 60092-353) engineered for 0.6/1 kV – 1.8/3 kV service across -40 to +90 °C (min. bend radius 8 × OD).
Typical values for this cable type, based on IEC 60092-353 / IEC 60092-360 SHF1 & SHF2 EMC Class — confirmed in the datasheet and quotation for your order.
Application fit
M2XCH-EMC & LKSM-EMC 0.6/1–1.8/3 kV Dual-Screened Shipboard Propulsion & VFD Cable (IEC 60092-353) engineered for 0.6/1 kV – 1.8/3 kV service across -40 to +90 °C (min. bend radius 8 × OD).
Symmetrical 3+3E split-earth geometry and dual 100% foil + copper braid screen contain PWM inverter common-mode currents.
Low phase capacitance and transfer impedance prevent bearing currents and voltage reflection spikes on variable-speed motors.
SHF2-MUD or IEEE 1580 Type P XL-CPE jacket resists oil-based drilling mud, ester fluids and marine weathering.
Qualified for high-power drawworks, top drives, mud pumps and dynamic-positioning (DP) thruster drives.
Fixed VFD propulsion and rig feeder cable is not intended for high-speed crane festoon loops.
Use (N)3GRDC5G-J/O Festoon CableConstruction
Shown: M2XCH-EMC & LKSM-EMC 0.6/1-1.8/3 KV (IEC 60092-353 / IEC 60092-360 SHF1 & SHF2 EMC Class) featuring main phase conductors (3×70 mm² xlpe), symmetrical split earth cores (3g10 mm²) and shf1 / shf2 halogen-free outer sheath (5-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | Main Phase Conductors (3×70 mm² XLPE) | Low-capacitance HF90 XLPE insulated phase cores (Brown, Black, Grey) |
| 2 | Symmetrical Split Earth Cores (3G10 mm²) | Three symmetrically placed Green/Yellow earth cores in outer interstices |
| 3 | 100% Copper / Foil Tape Screen (1st EMC) | Overlapped metallic tape providing 100% high-frequency EMI containment |
| 4 | High-Density Copper Wire Braid (2nd EMC) | Low transfer-impedance copper wire braid screen and armour |
| 5 | SHF1 / SHF2 Halogen-Free Outer Sheath | Flame-retardant zero-halogen marine jacket (IEC 60092-360) |
Built to IEC 60092-353 / IEC 60092-360 SHF1 & SHF2 EMC Class with main phase conductors (3×70 mm² xlpe) and shf1 / shf2 halogen-free outer sheath
Available in custom continuous shipboard/offshore drum lengths or with marine EMC cable glands
Supplied with EN 10204 3.1 routine dielectric, conductor resistance & flame/fire test report
Technical data
Sizes
Manufactured to IEC 60092-353 / IEC 60092-360 SHF1 & SHF2 EMC Class for shipboard, offshore platform, drilling rig and marine applications.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Tensile rating kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| M2XCH-EMC & LKSM-EMC 0.6/1-1.8/3 KV Construction Schedule (−40…+90 °C) | |||||||
| M2XCH-EMC 3×35+3G6 VFD | 3 × 35 + 3G6 mm² (3+3E EMC) | IEC 60228 Class 2/5 Cu/SnCu | 29.4 | 1,760 | 15.8 | 235 | |
| M2XCH-EMC 3×70+3G10 VFD | 3 × 70 + 3G10 mm² (3+3E EMC) | IEC 60228 Class 2/5 Cu/SnCu | 37.8 | 3,190 | 31.5 | 305 | |
| M2XCH-EMC 3×120+3G16 VFD | 3 × 120 + 3G16 mm² (3+3E EMC) | IEC 60228 Class 2/5 Cu/SnCu | 46.5 | 5,120 | 54.0 | 375 | |
| Configuration | Max. DC R₂₀ / Atten. Ω/km or dB/km | Rating / Impedance | Operating temp. |
|---|---|---|---|
| 3 × 35 + 3G6 mm² (3+3E EMC) | 0.52 | 0.6/1 kV – 1.8/3 kV (138 A VFD) | −40…+90 °C |
| 3 × 70 + 3G10 mm² (3+3E EMC) | 0.27 | 0.6/1 kV – 1.8/3 kV (215 A VFD) | −40…+90 °C |
| 3 × 120 + 3G16 mm² (3+3E EMC) | 0.15 | 0.6/1 kV – 1.8/3 kV (305 A VFD) | −40…+90 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance, continuity & dimensional verification (IEC 60092-353 / IEC 60092-360 SHF1 & SHF2 EMC Class) | DC resistance at 20 °C / optical attenuation and outer diameter within IEC 60092-353 / IEC 60092-360 SHF1 & SHF2 EMC Class tolerances | Every manufactured drum length |
| High-voltage dielectric & insulation resistance test (IEC 60092-353 / IEC 60092-360 SHF1 & SHF2 EMC Class) | Zero dielectric breakdown and verified insulation resistance for 0.6/1 kV – 1.8/3 kV rating | Every manufactured drum length |
| Sample tests | ||
| Flame, fire integrity, oil/mud & mechanical qualification (IEC 60092-353 / IEC 60092-360 SHF1 & SHF2 EMC Class) | Verified flame/fire performance, fluid resistance and thermal stability across −40…+90 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking