Fixed installation
Individually and/or collectively screened pairs and cores reject electrostatic and electromagnetic interference in high-EMC marine zones.
Product
37-102 Series IEEE 1580 Type P 600 V (1–37 Pairs, 16/18 AWG) Individually Shielded Offshore Pair Cable (IEEE 1580 Type P (37-102 Series)) engineered for 600 V (0.6/1 kV) service across -40 to +125 °C (min. bend radius 6 × OD).
Typical values for this cable type, based on IEEE Std 1580 Type P & UL 1309 (37-102 Series) 600 V Individually & Overall Shielded Pair Specification — confirmed in the datasheet and quotation for your order.
Application fit
37-102 Series IEEE 1580 Type P 600 V (1–37 Pairs, 16/18 AWG) Individually Shielded Offshore Pair Cable (IEEE 1580 Type P (37-102 Series)) engineered for 600 V (0.6/1 kV) service across -40 to +125 °C (min. bend radius 6 × OD).
Individually and/or collectively screened pairs and cores reject electrostatic and electromagnetic interference in high-EMC marine zones.
SHF2-MUD or IEEE 1580 Type P outer sheath resists drilling mud, ester fluids, hydrocarbons, salt spray and UV exposure.
Compact twisted pairs and numbered cores route cleanly into DCS/PLC cabinets, Ex-i barriers, sonar racks and bridge consoles.
Tinned copper, bronze or galvanized steel wire braid armour protects signal integrity in hazardous offshore zones.
Fixed shipboard and offshore instrumentation cable is not intended for high-speed crane festoon loops.
Use (N)3GRDC5G-J/O Festoon CableConstruction
Shown: 37-102 Type P Pair Cable (IEEE Std 1580 Type P & UL 1309 (37-102 Series) 600 V Individually & Overall Shielded Pair Specification) featuring 16/18 awg flexible tinned copper pairs (1-37 pr), individual pair al/pet foil shield & drain and cpe/lszh flame-retardant outer sheath (4-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | 16/18 AWG Flexible Tinned Copper Pairs ( | Finely stranded tinned copper with 110 °C XLPO Black/White insulation |
| 2 | Individual Pair Al/PET Foil Shield & Dra | 100% aluminum-polyester tape and tinned copper drain wire per pair |
| 3 | Bronze Wire Braid Mechanical Armour | Corrosion-resistant braided bronze wire armour over inner jacket |
| 4 | CPE/LSZH Flame-Retardant Outer Sheath | Heavy-duty thermoset jacket for winch encoders & lab instrumentation |
Built to IEEE Std 1580 Type P & UL 1309 (37-102 Series) 600 V Individually & Overall Shielded Pair Specification with 16/18 awg flexible tinned copper pairs (1-37 pr) and cpe/lszh flame-retardant outer sheath
Available in custom continuous subsea winch, tow or seabed lengths with water-blocked terminations
Supplied with EN 10204 3.1 routine dielectric, optical OTDR / DC resistance & tensile test report
Technical data
Sizes
Manufactured to IEEE Std 1580 Type P & UL 1309 (37-102 Series) 600 V Individually & Overall Shielded Pair Specification for subsea, oceanographic, ROV, seismic and offshore applications.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Breaking / tensile kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| 37-102 Type P Pair Cable Construction Schedule (−40…+125 °C) | |||||||
| 37-102 Type P Pair Cable 4Pr / 8Ch | 4×2×24–20 AWG (or 8-Ch Array) | Stranded SnCu + Foil/Braid + Aramid | 11.2 | 175 | 12.5 | 90 | |
| 37-102 Type P Pair Cable 8Pr / 16Ch | 8×2×22–18 AWG (or 16-Ch Array) | Stranded SnCu + Foil/Braid + Aramid | 16.4 | 340 | 24.0 | 130 | |
| 37-102 Type P Pair Cable 16Pr / 24Ch | 16×2×18–16 AWG (or 24-Ch Array) | Stranded SnCu + Foil/Braid + Aramid | 24.8 | 690 | 35.0 | 195 | |
| Configuration | Max. DC R₂₀ / Atten. Ω/km or dB/km | Rating / Impedance | Operating temp. |
|---|---|---|---|
| 4×2×24–20 AWG (or 8-Ch Array) | 42.00 | 600 V (0.6/1 kV) (≤55 nF/km) | −40…+125 °C |
| 8×2×22–18 AWG (or 16-Ch Array) | 26.00 | 600 V (0.6/1 kV) (≤60 nF/km) | −40…+125 °C |
| 16×2×18–16 AWG (or 24-Ch Array) | 15.20 | 600 V (0.6/1 kV) (≤65 nF/km) | −40…+125 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance, optical OTDR continuity & dimensional verification (IEEE Std 1580 Type P & UL 1309 (37-102 Series) 600 V Individually & Overall Shielded Pair Specification) | DC resistance at 20 °C / optical attenuation and outer diameter within IEEE Std 1580 Type P & UL 1309 (37-102 Series) 600 V Individually & Overall Shielded Pair Specification tolerances | Every manufactured drum length |
| High-voltage dielectric & insulation resistance test (IEEE Std 1580 Type P & UL 1309 (37-102 Series) 600 V Individually & Overall Shielded Pair Specification) | Zero dielectric breakdown and verified insulation resistance for 600 V (0.6/1 kV) rating | Every manufactured drum length |
| Sample tests | ||
| Hydrostatic pressure, tensile breaking load & water-blocking qualification (IEEE Std 1580 Type P & UL 1309 (37-102 Series) 600 V Individually & Overall Shielded Pair Specification) | Verified subsea pressure integrity, torque-balanced tensile performance and thermal stability across −40…+125 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.