Immersion & wet locations
Water-blocked core matrix and hydrolysis-resistant subsea jacketing withstand continuous deepwater hydrostatic pressure.
Product
26XM520 & 24XM521 Cat.6 / Cat.5 F/UTP Ethernet & 16/18-Core Power/Control Water-Blocked PUR Underwater LAN Hybrid Cable (TIA-568 / IEC 61156, 600 V, -30 °C to +80 °C, min. bend radius 10 × OD).
Typical values for this cable type, based on ANSI/TIA-568-C.2 / IEC 61156-6 Subsea LAN Standard — confirmed in the datasheet and quotation for your order.
Application fit
26XM520 & 24XM521 Cat.6 / Cat.5 F/UTP Ethernet & 16/18-Core Power/Control Water-Blocked PUR Underwater LAN Hybrid Cable (TIA-568 / IEC 61156, 600 V, -30 °C to +80 °C, min. bend radius 10 × OD).
Water-blocked core matrix and hydrolysis-resistant subsea jacketing withstand continuous deepwater hydrostatic pressure.
Torque-balanced aramid or contra-helical steel armour supports vertical winch deployment without hockling.
Marine-grade outer sheath and armour package resist LARS sheave abrasion, UV exposure and salt-spray corrosion.
High tensile breaking strength supports underwater towing, ROV excursion and seabed plough/trencher duty.
Subsea umbilical and tow construction is not intended for high-cycle indoor factory drag chains.
Use Drag-Chain Servo CableConstruction
Shown: 26XM520 & 24XM521 (ANSI/TIA-568-C.2 / IEC 61156-6 Subsea LAN Standard) featuring cat.6 / cat.5 f/utp lan core, power & control cores (18×22 / 16×24 awg) and polyurethane outer sheath (ø14.2 / 11.1 mm) (5-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | Cat.6 / Cat.5 F/UTP LAN Core | 4×2×24/7 AWG Cat.6 F/UTP (26XM520) or 4×2×26/7 AWG Cat.5 F/UTP (24XM521) data core |
| 2 | Power & Control Cores (18×22 / 16×24 AWG) | 18×22 AWG (26XM520) or 16×24 AWG (24XM521) stranded tinned copper conductors |
| 3 | SIWB / SWWB Water-Blocking | Silicone compound interstitial water-blocking (26XM520) or swellable tape (24XM521) |
| 4 | Braided Strength Member (480 / 320 kg) | High-tenacity aramid fiber braid supporting dynamic ROV & sonar deployment |
| 5 | Polyurethane Outer Sheath (Ø14.2 / 11.1 mm) | Black hydrolysis-resistant subsea polyurethane (PUR) outer jacket |
Built to ANSI/TIA-568-C.2 / IEC 61156-6 Subsea LAN Standard with cat.6 / cat.5 f/utp lan core and polyurethane outer sheath (ø14.2 / 11.1 mm)
Available in custom continuous subsea/wellbore drum lengths or pre-terminated assemblies
Supplied with EN 10204 3.1 routine dielectric, resistance & pressure/dimensional report
Technical data
Sizes
Manufactured to ANSI/TIA-568-C.2 / IEC 61156-6 Subsea LAN Standard for subsea, offshore, deep-well and marine applications.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Tensile rating kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| 26XM520 & 24XM521 Construction Schedule (−30…+80 °C) | |||||||
| 26XM520 Config A (Compact) | 4×2×24 AWG + 2×18 AWG (or 4C) | Stranded tinned Cu (IEC 60228 / ASTM) | 10.4 | 155 | 4.5 | 85 | |
| 26XM520 Config B (Standard) | 4×2×20 AWG + 4×16 AWG (or 8C) | Stranded tinned Cu (IEC 60228 / ASTM) | 13.3 | 265 | 9.6 | 110 | |
| 26XM520 Config C (Heavy Hybrid) | 8×2×20 AWG + 4×12 AWG (or 12C) | Stranded tinned Cu (IEC 60228 / ASTM) | 16.6 | 420 | 18.5 | 140 | |
| Configuration | Max. DC R₂₀ / Atten. Ω/km or dB/km | Rating / Impedance | Operating temp. |
|---|---|---|---|
| 4×2×24 AWG + 2×18 AWG (or 4C) | 28.40 | 600 V (45–100 Ω data) | −30…+80 °C |
| 4×2×20 AWG + 4×16 AWG (or 8C) | 10.70 | 600 V (45–100 Ω data) | −30…+80 °C |
| 8×2×20 AWG + 4×12 AWG (or 12C) | 5.40 | 600 V (High-Power Hybrid) | −30…+80 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance, continuity & dimensional verification (ANSI/TIA-568-C.2 / IEC 61156-6 Subsea LAN Standard) | DC resistance at 20 °C / optical attenuation and outer diameter within ANSI/TIA-568-C.2 / IEC 61156-6 Subsea LAN Standard tolerances | Every manufactured drum length |
| High-voltage dielectric & insulation resistance test (ANSI/TIA-568-C.2 / IEC 61156-6 Subsea LAN Standard) | Zero dielectric breakdown and verified insulation resistance for 600 V rating | Every manufactured drum length |
| Sample tests | ||
| Hydrostatic pressure, water-blocking & mechanical endurance qualification (ANSI/TIA-568-C.2 / IEC 61156-6 Subsea LAN Standard) | Verified submersion integrity, tensile load and thermal stability across −30…+80 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.