Immersion & wet locations
Water-blocked core matrix and hydrolysis-resistant subsea jacketing withstand continuous deepwater hydrostatic pressure.
Product
245 kV (250 MW) Three-Core Dry-Design HVAC Dynamic Submarine Export Cable with Corrugated Welded Copper Metallic Sheath, Double Galvanized Flat Steel Wire Armour & PE Outer Sheath (IEC 62067 / CIGRE TB 862, 19/33 kV, -20 °C to +90 °C).
Typical values for this cable type, based on IEC 62067 / CIGRE TB 490, TB 722 & TB 862 Dynamic Export — confirmed in the datasheet and quotation for your order.
Application fit
245 kV (250 MW) Three-Core Dry-Design HVAC Dynamic Submarine Export Cable with Corrugated Welded Copper Metallic Sheath, Double Galvanized Flat Steel Wire Armour & PE Outer Sheath (IEC 62067 / CIGRE TB 862, 19/33 kV, -20 °C to +90 °C).
Water-blocked core matrix and hydrolysis-resistant subsea jacketing withstand continuous deepwater hydrostatic pressure.
Torque-balanced aramid or contra-helical steel armour supports vertical winch deployment without hockling.
Marine-grade outer sheath and armour package resist LARS sheave abrasion, UV exposure and salt-spray corrosion.
High tensile breaking strength supports underwater towing, ROV excursion and seabed plough/trencher duty.
Subsea umbilical and tow construction is not intended for high-cycle indoor factory drag chains.
Use Drag-Chain Servo CableConstruction
Shown: 245KV HVAC DYNAMIC CABLE (IEC 62067 / CIGRE TB 490, TB 722 & TB 862 Dynamic Export) featuring water-blocked cu conductors (ø41.5 mm, id 1), 245 kv xlpe & semicon screens (id 2–5) and double flat steel armour & pe sheath (id 9–13) (5-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | Water-Blocked Cu Conductors (Ø41.5 mm, ID 1) | Stranded round longitudinally water-blocked Class 2 copper conductors (250 MW) |
| 2 | 245 kV XLPE & Semicon Screens (ID 2–5) | Triple-extruded semicon screens + 245 kV XLPE insulation + water-blocking tapes |
| 3 | Corrugated Copper Welded Sheath (ID 6–7) | Fatigue-resistant dry-design corrugated welded copper sheath + PE core jacket |
| 4 | Shaped PE Fillers & 48 SM FO Cable (ID 8, 14) | Pre-shaped polyethylene fillers + integrated 48 single-mode fiber-optic cable |
| 5 | Double Flat Steel Armour & PE Sheath (ID 9–13) | Contra-helical double galvanized flat steel armour + extruded yellow PE outer sheath |
Built to IEC 62067 / CIGRE TB 490, TB 722 & TB 862 Dynamic Export with water-blocked cu conductors (ø41.5 mm, id 1) and double flat steel armour & pe sheath (id 9–13)
Available in custom continuous subsea/wellbore drum lengths or pre-terminated assemblies
Supplied with EN 10204 3.1 routine dielectric, resistance & pressure/dimensional report
Technical data
Sizes
Manufactured to IEC 62067 / CIGRE TB 490, TB 722 & TB 862 Dynamic Export for subsea, offshore, deep-well and marine applications.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Tensile rating kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| 245KV HVAC DYNAMIC CABLE Construction Schedule (−20…+90 °C) | |||||||
| 245KV HVAC DYNAMIC CABLE 3×240 mm² + FO | 3 × 240 mm² + 48F FIMT | IEC 60228 Class 2 water-blocked Cu | 118.0 | 26,400 | 320.0 | 1,770 | |
| 245KV HVAC DYNAMIC CABLE 3×400 mm² + FO | 3 × 400 mm² + 48F FIMT | IEC 60228 Class 2 water-blocked Cu | 134.0 | 34,800 | 420.0 | 2,010 | |
| 245KV HVAC DYNAMIC CABLE 3×630 mm² + FO | 3 × 630 mm² + 96F FIMT | IEC 60228 Class 2 water-blocked Cu | 152.0 | 46,200 | 560.0 | 2,280 | |
| Configuration | Max. DC R₂₀ / Atten. Ω/km or dB/km | Rating / Impedance | Operating temp. |
|---|---|---|---|
| 3 × 240 mm² + 48F FIMT | 0.08 | 19/33 kV (560 A) | −20…+90 °C |
| 3 × 400 mm² + 48F FIMT | 0.05 | 19/33 kV (710 A) | −20…+90 °C |
| 3 × 630 mm² + 96F FIMT | 0.03 | 19/33 kV (890 A) | −20…+90 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance, continuity & dimensional verification (IEC 62067 / CIGRE TB 490, TB 722 & TB 862 Dynamic Export) | DC resistance at 20 °C / optical attenuation and outer diameter within IEC 62067 / CIGRE TB 490, TB 722 & TB 862 Dynamic Export tolerances | Every manufactured drum length |
| High-voltage dielectric & insulation resistance test (IEC 62067 / CIGRE TB 490, TB 722 & TB 862 Dynamic Export) | Zero dielectric breakdown and verified insulation resistance for 19/33 kV rating | Every manufactured drum length |
| Sample tests | ||
| Hydrostatic pressure, water-blocking & mechanical endurance qualification (IEC 62067 / CIGRE TB 490, TB 722 & TB 862 Dynamic Export) | Verified submersion integrity, tensile load and thermal stability across −20…+90 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.