Immersion & wet locations
Hydrolysis-resistant polyurethane (PUR) or HDPE jacket and water-blocked core withstand continuous deepwater hydrostatic immersion.
Product
10 kV DC 24–48F G.654E / G.652D Laser-Welded SS & Copper-Tube Subsea Observatory Trunk Cable (ITU-T G.972 / 10 kV DC Subsea) engineered for 10 kV DC service across -20 to +70 °C (min. bend radius 20 × OD).
Typical values for this cable type, based on ITU-T G.972 / G.654E 10 kV DC Cabled Subsea Observatory Electro-Optical Trunk Specification — confirmed in the datasheet and quotation for your order.
Application fit
10 kV DC 24–48F G.654E / G.652D Laser-Welded SS & Copper-Tube Subsea Observatory Trunk Cable (ITU-T G.972 / 10 kV DC Subsea) engineered for 10 kV DC service across -20 to +70 °C (min. bend radius 20 × OD).
Hydrolysis-resistant polyurethane (PUR) or HDPE jacket and water-blocked core withstand continuous deepwater hydrostatic immersion.
Torque-balanced contra-helical steel wire armour or high-modulus aramid strength member supports dynamic winch deployment without hockling
Abrasion-resistant outer sheath and high working-load strength elements handle dynamic marine towing, buoy mooring and ROV excursion.
UV-stabilised, oil- and seawater-resistant construction withstands A-frame sheaves, traction winches and open research-vessel decks.
Subsea umbilical, ROV tether and towed array cables are not designed for indoor factory automation drag chains.
Use M23 Servo AssemblyConstruction
Shown: 10kVDC Observatory Trunk (ITU-T G.972 / G.654E 10 kV DC Cabled Subsea Observatory Electro-Optical Trunk Specification) featuring laser-welded ss tube (24–48×g.654e/g.652d), steel pressure vault & copper conductor tube and double galvanized steel armour & pp serving (4-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | Laser-Welded SS Tube (24–48×G.654E/G.652 | Hermetic stainless-steel tube housing ultra-low-loss single-mode fibers |
| 2 | Steel Pressure Vault & Copper Conductor | High-strength steel vault + continuous copper tube for 10 kV DC feed |
| 3 | 10kV DC High-Purity MDPE / HDPE Insulati | High-voltage direct-current polyethylene dielectric |
| 4 | Double Galvanized Steel Armour & PP Serv | LWISAIDA galvanized steel wire armour + polypropylene outer serving |
Built to ITU-T G.972 / G.654E 10 kV DC Cabled Subsea Observatory Electro-Optical Trunk Specification with laser-welded ss tube (24–48×g.654e/g.652d) and double galvanized steel armour & pp serving
Available in custom continuous subsea winch, tow or seabed lengths with water-blocked terminations
Supplied with EN 10204 3.1 routine dielectric, optical OTDR / DC resistance & tensile test report
Technical data
Sizes
Manufactured to ITU-T G.972 / G.654E 10 kV DC Cabled Subsea Observatory Electro-Optical Trunk Specification for subsea, oceanographic, ROV, seismic and offshore applications.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Breaking / tensile kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| 10kVDC Observatory Trunk Construction Schedule (−20…+70 °C) | |||||||
| 10kVDC Observatory Trunk Config A | 3×25–50 mm² (or 3P+FO Composite) | Compacted / Class 5 Cu/SnCu + FO | 32.0 | 1,850 | 85.0 | 380 | |
| 10kVDC Observatory Trunk Config B | 3×95–150 mm² (or Heavy EOM) | Compacted / Class 5 Cu/SnCu + FO | 48.5 | 4,280 | 130.0 | 580 | |
| 10kVDC Observatory Trunk Config C | 3×240–400 mm² (or Trunk HV/MV) | Compacted Cu + Lead/Armour + FO | 78.0 | 9,650 | 210.0 | 950 | |
| Configuration | Max. DC R₂₀ / Atten. Ω/km or dB/km | Rating / Impedance | Operating temp. |
|---|---|---|---|
| 3×25–50 mm² (or 3P+FO Composite) | 0.50 | 10 kV DC (Subsea/MV) | −20…+70 °C |
| 3×95–150 mm² (or Heavy EOM) | 0.19 | 10 kV DC (Subsea/MV) | −20…+70 °C |
| 3×240–400 mm² (or Trunk HV/MV) | 0.08 | 10 kV DC (Trunk/HV) | −20…+70 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance, optical OTDR continuity & dimensional verification (ITU-T G.972 / G.654E 10 kV DC Cabled Subsea Observatory Electro-Optical Trunk Specification) | DC resistance at 20 °C / optical attenuation and outer diameter within ITU-T G.972 / G.654E 10 kV DC Cabled Subsea Observatory Electro-Optical Trunk Specification tolerances | Every manufactured drum length |
| High-voltage dielectric & insulation resistance test (ITU-T G.972 / G.654E 10 kV DC Cabled Subsea Observatory Electro-Optical Trunk Specification) | Zero dielectric breakdown and verified insulation resistance for 10 kV DC rating | Every manufactured drum length |
| Sample tests | ||
| Hydrostatic pressure, tensile breaking load & water-blocking qualification (ITU-T G.972 / G.654E 10 kV DC Cabled Subsea Observatory Electro-Optical Trunk Specification) | Verified subsea pressure integrity, torque-balanced tensile performance and thermal stability across −20…+70 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.