Trailing & towing
Engineered for heavy-duty mobile mining and industrial trailing duty per AS/NZS 5000.1 / AS/NZS 1125 / PN-90/E-90100.
Product
Engineered for underground mining, open-cast excavation, shaft infrastructure and heavy industrial service per AS/NZS 5000.1 / AS/NZS 1125 / PN-90/E-90100 across -25 to +90 °C.
Typical values for this cable type, based on AS/NZS 5000.1 / AS/NZS 1125 / PN-90/E-90100 — confirmed in the datasheet and quotation for your order.
Application fit
Engineered for underground mining, open-cast excavation, shaft infrastructure and heavy industrial service per AS/NZS 5000.1 / AS/NZS 1125 / PN-90/E-90100 across -25 to +90 °C.
Engineered for heavy-duty mobile mining and industrial trailing duty per AS/NZS 5000.1 / AS/NZS 1125 / PN-90/E-90100.
Suitable for underground coal/hard-rock roadways, shuttle cars and quarry feeders (-25 to +90 °C).
Can be installed on cable trays, hangers and mobile skid interconnections within 8 × OD.
Not optimized for high-speed overhead crane C-track festoon loops; select a dedicated festoon cable.
NGFLGÖU Flat Rubber Festoon CableConstruction
Shown: 15000BE (OGŁ) (AS/NZS 5000.1 / AS/NZS 1125 / PN-90/E-90100) featuring power & earth cores (4×25 mm²), thermistor/moisture pilots (4×1.5 mm²) and submersible blue tpv outer sheath (5-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | Power & Earth Cores (4×25 mm²) | Class 5 rope-stranded tinned copper + Red, White, Blue & G/Y R-EP-90 EPR |
| 2 | Thermistor/Moisture Pilots (4×1.5 mm²) | Four numbered black R-EP-90 EPR tinned copper monitoring cores in interstices |
| 3 | TPV Elastomer Inner Bedding | Extruded black thermoplastic vulcanizate inner sheath rounding core lay-up |
| 4 | Overall Tinned Copper Braid (85%) | 85% coverage tinned copper braid for VFD EMC & mechanical earth fault protection |
| 5 | Submersible Blue TPV Outer Sheath | Heavy-duty oil-, acid- and abrasion-resistant blue TPV jacket (500 m depth) |
Built to AS/NZS 5000.1 / AS/NZS 1125 / PN-90/E-90100 with power & earth cores (4×25 mm²) and submersible blue tpv outer sheath
Available in custom shaft/roadway drum lengths or pre-terminated assemblies
Supplied with EN 10204 3.1 routine dielectric, resistance & flame test report
Technical data
Sizes
Manufactured to AS/NZS 5000.1 / AS/NZS 1125 / PN-90/E-90100 for underground mining, open-cast excavation, shaft and heavy industrial systems.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Tensile rating kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| 15000BE (OGŁ) Construction Schedule (-25 to +90 °C) | |||||||
| 15000BE (OGŁ) 4×16 + 4×1.5 mm² | 4×16 mm² + 4×1.5 mm² | Class 5 tinned Cu | 26.8 | 1,340 | 9.6 | 215 | |
| 15000BE (OGŁ) 4×25 + 4×1.5 mm² | 4×25 mm² + 4×1.5 mm² | Class 5 tinned Cu | 31.2 | 1,920 | 15.0 | 250 | |
| 15000BE (OGŁ) 4×35 + 4×1.5 mm² | 4×35 mm² + 4×1.5 mm² | Class 5 tinned Cu | 35.0 | 2,510 | 21.0 | 280 | |
| Configuration | Max. DC R₂₀ / Atten. Ω/km or dB/km | Rating / Impedance | Operating temp. |
|---|---|---|---|
| 4×16 mm² + 4×1.5 mm² | 1.24 | 0.6/1 kV (98 A) | -25 to +90 °C |
| 4×25 mm² + 4×1.5 mm² | 0.80 | 0.6/1 kV (128 A) | -25 to +90 °C |
| 4×35 mm² + 4×1.5 mm² | 0.57 | 0.6/1 kV (158 A) | -25 to +90 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance, continuity & dimensional verification (AS/NZS 5000.1 / AS/NZS 1125 / PN-90/E-90100) | DC resistance at 20 °C / optical attenuation and outer diameter within AS/NZS 5000.1 / AS/NZS 1125 / PN-90/E-90100 tolerances | Every manufactured drum length |
| High-voltage dielectric & insulation resistance test (AS/NZS 5000.1 / AS/NZS 1125 / PN-90/E-90100) | Zero dielectric breakdown and verified insulation resistance over full production length | Every manufactured drum length |
| Sample tests | ||
| Flame propagation, mechanical crush & thermal ageing qualification (AS/NZS 5000.1 / AS/NZS 1125 / PN-90/E-90100) | Verified flame retardancy, mechanical integrity and thermal endurance across -25 to +90 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.