Mine roadway & tunnel wall hangers
Engineered for underground mining shafts, galleries and tunnel infrastructure per TIA/EIA-568-B.2 Cat 5e / UL 444 / MSHA.
Product
Engineered for underground mining, open-cast excavation, shaft infrastructure and heavy industrial service per TIA/EIA-568-B.2 Cat 5e / UL 444 / MSHA across -40 to +75 °C.
Typical values for this cable type, based on TIA/EIA-568-B.2 Cat 5e / UL 444 / MSHA — confirmed in the datasheet and quotation for your order.
Application fit
Engineered for underground mining, open-cast excavation, shaft infrastructure and heavy industrial service per TIA/EIA-568-B.2 Cat 5e / UL 444 / MSHA across -40 to +75 °C.
Engineered for underground mining shafts, galleries and tunnel infrastructure per TIA/EIA-568-B.2 Cat 5e / UL 444 / MSHA.
Suitable for vertical shaft cleats, gallery messenger hooks and tray routing within 10 × OD.
Supports inclined roadway and vertical mine shaft suspension within rated kN load across -40 to +75 °C.
Not optimized for high-speed overhead crane C-track festoon loops; select a dedicated festoon cable.
NGFLGÖU Flat Rubber Festoon CableConstruction
Shown: 121700A (TIA/EIA-568-B.2 Cat 5e / UL 444 / MSHA) featuring bonded-pair conductors (4×2×24 awg), 100% aluminum/polyester foil shield & drain and msha industrial outer jacket (5-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | Bonded-Pair Conductors (4×2×24 AWG) | Solid bare copper with physically bonded TIA-568 polyolefin pairs |
| 2 | 100% Al/PET Foil Shield & Drain Wire | 100% aluminum/polyester foil shield + 24 AWG stranded tinned copper drain wire |
| 3 | Inner Jacket & Polyester Wrap | Extruded industrial black PVC inner jacket + polyester separator tape |
| 4 | Interlocked Aluminum Armor (121700A) | Helically interlocked aluminum strip armor for rockfall & crush protection |
| 5 | MSHA Industrial Outer Jacket | Oil-, sunlight- and flame-resistant MSHA-approved PVC outer jacket |
Built to TIA/EIA-568-B.2 Cat 5e / UL 444 / MSHA with bonded-pair conductors (4×2×24 awg) and msha industrial outer jacket
Available in custom shaft/roadway drum lengths or pre-terminated assemblies
Supplied with EN 10204 3.1 routine dielectric, resistance & flame test report
Technical data
Sizes
Manufactured to TIA/EIA-568-B.2 Cat 5e / UL 444 / MSHA for underground mining, open-cast excavation, shaft and heavy industrial systems.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Tensile rating kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| 121700A Construction Schedule (-40 to +75 °C) | |||||||
| 121700A Cat 5e AIA Black MSHA | 4 × 2 × 24 AWG (Cat 5e F/UTP) | Solid bare Cu bonded pairs | 12.9 | 178 | 0.9 | 130 | |
| 121700A Cat 5e AIA Blue Ex-i Zone | 4 × 2 × 24 AWG (Cat 5e F/UTP) | Solid bare Cu bonded pairs | 12.9 | 178 | 0.9 | 130 | |
| 121700A Cat 5e AIA Grey Plant Trunk | 4 × 2 × 24 AWG (Cat 5e F/UTP) | Solid bare Cu bonded pairs | 12.9 | 178 | 0.9 | 130 | |
| Configuration | Max. DC R₂₀ / Atten. Ω/km or dB/km | Rating / Impedance | Operating temp. |
|---|---|---|---|
| 4 × 2 × 24 AWG (Black MSHA) | 90.00 | 100 Ω ± 15 Ω (1–100 MHz) | -40 to +75 °C |
| 4 × 2 × 24 AWG (Blue Ex-i) | 90.00 | 100 Ω ± 15 Ω (1–100 MHz) | -40 to +75 °C |
| 4 × 2 × 24 AWG (Grey Trunk) | 90.00 | 100 Ω ± 15 Ω (1–100 MHz) | -40 to +75 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance, continuity & dimensional verification (TIA/EIA-568-B.2 Cat 5e / UL 444 / MSHA) | DC resistance at 20 °C / optical attenuation and outer diameter within TIA/EIA-568-B.2 Cat 5e / UL 444 / MSHA tolerances | Every manufactured drum length |
| High-voltage dielectric & insulation resistance test (TIA/EIA-568-B.2 Cat 5e / UL 444 / MSHA) | Zero dielectric breakdown and verified insulation resistance over full production length | Every manufactured drum length |
| Sample tests | ||
| Flame propagation, mechanical crush & thermal ageing qualification (TIA/EIA-568-B.2 Cat 5e / UL 444 / MSHA) | Verified flame retardancy, mechanical integrity and thermal endurance across -40 to +75 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.