Contact

07BN2-F & H07RN-F OR 450/750 V Thermal & Oil Water Pump CableEN 50525-2-21 · 450/750 V · Aggressive thermal-water & oil-sludge submersible cable

07BN2-F (Thermal-Water +85°C Thermal/Aggressive-Water Orange CPE Submersible Pump Cable) & H07RN-F OR (Oil-Resistant Tinned-Copper Oil-Polluted Water Submersible Cable) (EN 50525-2-21, 450/750 V, -25 °C to +85 °C).

Water-resistant
Oil-resistant
Flame-retardant
Ozone, UV & moisture
Order designation
07BN2-F 4G16 mm²
Outer Ø ≈
21.8 mm
Net weight ≈
840 kg/km
Tensile rating ≈
2.4 kN
Core / stranding
IEC 60228 Class 5 flexible Cu/SnCu
All sizes (3)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
450/750 V
Tested per EN 50525-2-21
Operating temp.
−25…+85 °C
Continuous subsea & marine service
Min. bend radius
6 × OD
Dynamic sheave & fixed routing
Core / conductor
3G–4G 1.5–50 mm²
IEC 60228 Class 5 flexible SnCu
Outer protection
Orange CPE/OR CR
+85 °C thermal-water CPE or oil-sludge
Standard
EN 50525-2-21
DIN EN 50525-2-21 / IEC 60245

Typical values for this cable type, based on DIN EN 50525-2-21 / IEC 60245 — confirmed in the datasheet and quotation for your order.

Application fit

Is 07BN2-F & H07RN-F OR right for your machine?

07BN2-F (Thermal-Water +85°C Thermal/Aggressive-Water Orange CPE Submersible Pump Cable) & H07RN-F OR (Oil-Resistant Tinned-Copper Oil-Polluted Water Submersible Cable) (EN 50525-2-21, 450/750 V, -25 °C to +85 °C).

Immersion & wet locations

Suitable

Cross-linked submersible elastomer compound is qualified for continuous deep-well, potable-water or sewage immersion.

Free-hanging vertical run

Suitable

High-modulus conductor and elastomer construction supports vertical suspension in deep boreholes and pump risers.

Trailing & towing

Suitable

Tear- and abrasion-resistant rubber outer sheath handles mobile dewatering, dredger and portable pump deployment.

Fixed installation

Suitable

Suitable for permanent wet-well, treatment tank, geothermal borehole and submergedmanifold installations.

Energy chain / drag chain

Not suitable

Submersible rubber pump cable is not intended for high-acceleration automation drag chains.

Use Drag-Chain Control Cable
Typical machinesMarine & Offshore CableDeep-Well Potable Water PumpingMunicipal Sewage & Wastewater PlantsMine Dewatering & Slurry DredgingGeothermal, Spa & Pool Installations

Construction

Layer by layer

Shown: 07BN2-F & H07RN-F OR (DIN EN 50525-2-21 / IEC 60245) featuring class 5 tinned copper conductors, heat-resistant epr insulation (450/750 v) and orange cpe thermal-water sheath (+85 °c) (3-layer construction).

123
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1Class 5 Tinned Copper ConductorsIEC 60228 Class 5 flexible tinned copper resisting sulfurous & acidic water corrosion
2Heat-Resistant EPR Insulation (450/750 V)Cross-linked EPR core insulation color-coded Brown, Black, Blue & Green/Yellow
3Orange CPE Thermal-Water Sheath (+85 °C)Orange CPE-based elastomer for +85 °C aggressive thermal/spa wells (Black OR rubber on Oil-Resistant)

07BN2-F & H07RN-F OR — Standard Subsea & Marine Execution

Built to DIN EN 50525-2-21 / IEC 60245 with class 5 tinned copper conductors and orange cpe thermal-water sheath (+85 °c)

07BN2-F & H07RN-F OR — Custom Drum Length & Termination Kit

Available in custom continuous subsea/wellbore drum lengths or pre-terminated assemblies

07BN2-F & H07RN-F OR — Routine & Hydrostatic Test Certified

Supplied with EN 10204 3.1 routine dielectric, resistance & pressure/dimensional report

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on DIN EN 50525-2-21 / IEC 60245. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage / transmission duty
450/750 V (DIN EN 50525-2-21 / IEC 60245)
Core / conductor construction
Class 5 Tinned Copper Conductors — IEC 60228 Class 5 flexible tinned copper resisting sulfurous & acidic water corrosion
Primary dielectric / buffering
Heat-Resistant EPR Insulation (450/750 V) — Cross-linked EPR core insulation color-coded Brown, Black, Blue & Green/Yellow

Thermal

Continuous operating temperature
−25…+85 °C (subsea, marine & submersible duty)
Short-circuit / peak thermal rating
Verified thermal stability per DIN EN 50525-2-21 / IEC 60245
Storage & transport temperature
−40…+80 °C on export wooden/steel drum

Mechanical

Outer protection / armouring
Orange CPE Thermal-Water Sheath (+85 °C) — Orange CPE-based elastomer for +85 °C aggressive thermal/spa wells (Black OR rubber on Oil-Resistant)
Minimum bending radius
6 × OD
Hydrostatic, tensile & crush duty
Heat-Resistant EPR Insulation (450/750 V) — Cross-linked EPR core insulation color-coded Brown, Black, Blue & Green/Yellow

Resistance

Hydrostatic pressure & water blocking
Engineered for continuous submersion and hydrostatic integrity per DIN EN 50525-2-21 / IEC 60245
Seawater, oil & chemical resistance
Resistant to seawater hydrolysis, hydraulic oils and abrasion per DIN EN 50525-2-21 / IEC 60245
RoHS & REACH compliance
RoHS 2 (2011/65/EU + 2015/863) & REACH SVHC compliant

Reference standards

Governing standard
DIN EN 50525-2-21 / IEC 60245
Environmental & test standards
IEC 60228 / IEC 60332 / ISO 13628-5 / EN 10204
Quality management & inspection
ISO 9001:2015 & EN 10204 3.1 factory routine inspection

Identification

Model designation
07BN2-F & H07RN-F OR
Sheath colour & metre marking
Continuous metre-marked orange outer finish (Orange CPE / OR CR)
Customs tariff (HS)
8544.49 / 8544.60 / 8544.70

Sizes

3 standard 07BN2-F & H07RN-F OR subsea & marine configurations

Manufactured to DIN EN 50525-2-21 / IEC 60245 for subsea, offshore, deep-well and marine applications.

Dimensions, tensile load & weights
Order designationConfigurationCore / strandingOuter Ø ≈
mm
Net weight ≈
kg/km
Tensile rating
kN ≈
Min. bend R
mm
Enquiry
07BN2-F & H07RN-F OR Construction Schedule (−25…+85 °C)
07BN2-F 4G16 mm²4G16 mm² (3×16 + 1G16)IEC 60228 Class 5 flexible Cu/SnCu21.88402.4130
07BN2-F 4G35 mm²4G35 mm² (3×35 + 1G16)IEC 60228 Class 5 flexible Cu/SnCu28.61,6205.2172
07BN2-F 3×70 + 3G16 mm²3 × 70 mm² + 3G16 mm²IEC 60228 Class 5 flexible Cu/SnCu38.43,18010.5230
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Custom core cross-sections, pair/fibre counts, armour grades and factory drum lengths available per DIN EN 50525-2-21 / IEC 60245.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
Conductor resistance, continuity & dimensional verification (DIN EN 50525-2-21 / IEC 60245)DC resistance at 20 °C / optical attenuation and outer diameter within DIN EN 50525-2-21 / IEC 60245 tolerancesEvery manufactured drum length
High-voltage dielectric & insulation resistance test (DIN EN 50525-2-21 / IEC 60245)Zero dielectric breakdown and verified insulation resistance for 450/750 V ratingEvery manufactured drum length
Sample tests
Hydrostatic pressure, water-blocking & mechanical endurance qualification (DIN EN 50525-2-21 / IEC 60245)Verified submersion integrity, tensile load and thermal stability across −25…+85 °CType qualification & periodic lot audit

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

EN 50525-2-21 CompliantEN 10204 3.1 Factory Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

TEBAOFLEX 07BN2-F & H07RN-F OR EN 50525-2-21 450/750 V CE
Delivery form
Heavy-duty export fumigated wooden drums or steel subsea reels
Standard lengths
500 m, 1,000 m or custom continuous subsea/wellbore lengths
MOQ
100 m (standard configurations) · 500 m (custom builds)
Lead time
2–5 weeks ex-works
Incoterms
EXW, FCA, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-10-25
Updated
2026-10-25

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What governing standard and construction define 07BN2-F & H07RN-F OR (07BN2-F & H07RN-F OR 450/750 V Thermal & Oil Water Pump Cable)?
07BN2-F & H07RN-F OR (07BN2-F & H07RN-F OR 450/750 V Thermal & Oil Water Pump Cable) is manufactured in accordance with DIN EN 50525-2-21 / IEC 60245 for 450/750 V service over -25 °C to +85 °C. Its 3-layer construction comprises class 5 tinned copper conductors, heat-resistant epr insulation (450/750 v) and orange cpe thermal-water sheath (+85 °c).
What is the minimum bending radius and operating temperature range for 07BN2-F & H07RN-F OR?
The minimum bending radius for 07BN2-F & H07RN-F OR is 6 × OD across its continuous operating temperature range of -25 °C to +85 °C, ensuring mechanical and dielectric reliability in subsea, marine and submersible service.
How are the concentric layers of 07BN2-F & H07RN-F OR arranged from inside to outside?
From inside to outside, the construction sequence is: (01) Class 5 Tinned Copper Conductors — IEC 60228 Class 5 flexible tinned copper resisting sulfurous & acidic water corrosion; (02) Heat-Resistant EPR Insulation (450/750 V) — Cross-linked EPR core insulation color-coded Brown, Black, Blue & Green/Yellow; (03) Orange CPE Thermal-Water Sheath (+85 °C) — Orange CPE-based elastomer for +85 °C aggressive thermal/spa wells (Black OR rubber on Oil-Resistant).
What factory test certificates are supplied with 07BN2-F & H07RN-F OR?
Every production drum of 07BN2-F & H07RN-F OR undergoes routine conductor resistance/continuity, high-voltage dielectric and dimensional testing per DIN EN 50525-2-21 / IEC 60245, and is delivered with an EN 10204 3.1 factory test certificate.

Request a quote

Get an engineering quote for 07BN2-F & H07RN-F OR

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

07BN2-F & H07RN-F OR 450/750 V Thermal & Oil Water Pump Cable

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp