Immersion & wet locations
Cross-linked submersible elastomer compound is qualified for continuous deep-well, potable-water or sewage immersion.
Product
07BN2-F (Thermal-Water +85°C Thermal/Aggressive-Water Orange CPE Submersible Pump Cable) & H07RN-F OR (Oil-Resistant Tinned-Copper Oil-Polluted Water Submersible Cable) (EN 50525-2-21, 450/750 V, -25 °C to +85 °C).
Typical values for this cable type, based on DIN EN 50525-2-21 / IEC 60245 — confirmed in the datasheet and quotation for your order.
Application fit
07BN2-F (Thermal-Water +85°C Thermal/Aggressive-Water Orange CPE Submersible Pump Cable) & H07RN-F OR (Oil-Resistant Tinned-Copper Oil-Polluted Water Submersible Cable) (EN 50525-2-21, 450/750 V, -25 °C to +85 °C).
Cross-linked submersible elastomer compound is qualified for continuous deep-well, potable-water or sewage immersion.
High-modulus conductor and elastomer construction supports vertical suspension in deep boreholes and pump risers.
Tear- and abrasion-resistant rubber outer sheath handles mobile dewatering, dredger and portable pump deployment.
Suitable for permanent wet-well, treatment tank, geothermal borehole and submergedmanifold installations.
Submersible rubber pump cable is not intended for high-acceleration automation drag chains.
Use Drag-Chain Control CableConstruction
Shown: 07BN2-F & H07RN-F OR (DIN EN 50525-2-21 / IEC 60245) featuring class 5 tinned copper conductors, heat-resistant epr insulation (450/750 v) and orange cpe thermal-water sheath (+85 °c) (3-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | Class 5 Tinned Copper Conductors | IEC 60228 Class 5 flexible tinned copper resisting sulfurous & acidic water corrosion |
| 2 | Heat-Resistant EPR Insulation (450/750 V) | Cross-linked EPR core insulation color-coded Brown, Black, Blue & Green/Yellow |
| 3 | Orange CPE Thermal-Water Sheath (+85 °C) | Orange CPE-based elastomer for +85 °C aggressive thermal/spa wells (Black OR rubber on Oil-Resistant) |
Built to DIN EN 50525-2-21 / IEC 60245 with class 5 tinned copper conductors and orange cpe thermal-water sheath (+85 °c)
Available in custom continuous subsea/wellbore drum lengths or pre-terminated assemblies
Supplied with EN 10204 3.1 routine dielectric, resistance & pressure/dimensional report
Technical data
Sizes
Manufactured to DIN EN 50525-2-21 / IEC 60245 for subsea, offshore, deep-well and marine applications.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Tensile rating kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| 07BN2-F & H07RN-F OR Construction Schedule (−25…+85 °C) | |||||||
| 07BN2-F 4G16 mm² | 4G16 mm² (3×16 + 1G16) | IEC 60228 Class 5 flexible Cu/SnCu | 21.8 | 840 | 2.4 | 130 | |
| 07BN2-F 4G35 mm² | 4G35 mm² (3×35 + 1G16) | IEC 60228 Class 5 flexible Cu/SnCu | 28.6 | 1,620 | 5.2 | 172 | |
| 07BN2-F 3×70 + 3G16 mm² | 3 × 70 mm² + 3G16 mm² | IEC 60228 Class 5 flexible Cu/SnCu | 38.4 | 3,180 | 10.5 | 230 | |
| Configuration | Max. DC R₂₀ / Atten. Ω/km or dB/km | Rating / Impedance | Operating temp. |
|---|---|---|---|
| 4G16 mm² (3×16 + 1G16) | 1.21 | 450/750 V (94 A submerged) | −25…+85 °C |
| 4G35 mm² (3×35 + 1G16) | 0.55 | 450/750 V (152 A submerged) | −25…+85 °C |
| 3 × 70 mm² + 3G16 mm² | 0.27 | 450/750 V (235 A submerged) | −25…+85 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance, continuity & dimensional verification (DIN EN 50525-2-21 / IEC 60245) | DC resistance at 20 °C / optical attenuation and outer diameter within DIN EN 50525-2-21 / IEC 60245 tolerances | Every manufactured drum length |
| High-voltage dielectric & insulation resistance test (DIN EN 50525-2-21 / IEC 60245) | Zero dielectric breakdown and verified insulation resistance for 450/750 V rating | Every manufactured drum length |
| Sample tests | ||
| Hydrostatic pressure, water-blocking & mechanical endurance qualification (DIN EN 50525-2-21 / IEC 60245) | Verified submersion integrity, tensile load and thermal stability across −25…+85 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.