Immersion & wet locations
Hydrolysis-resistant ether-grade PUR/TPU jackets, water-blocked cores and optional atmospheric vent tubes support permanent immersion.
Product
02-250V6 Vented Polyurethane Submersible Sensor Cable featuring central atmospheric vent tube and subsea / marine outer protective sheath (IEC 60770 / EN 50288, 300 V, -30 to +80 °C, min. bend radius 6 × OD).
Typical values for this cable type, based on IEC 60770 & EN 50288 02-250V6 Vented Polyurethane Level Sensor Specification — confirmed in the datasheet and quotation for your order.
Application fit
02-250V6 Vented Polyurethane Submersible Sensor Cable featuring central atmospheric vent tube and subsea / marine outer protective sheath (IEC 60770 / EN 50288, 300 V, -30 to +80 °C, min. bend radius 6 × OD).
Hydrolysis-resistant ether-grade PUR/TPU jackets, water-blocked cores and optional atmospheric vent tubes support permanent immersion.
Integrated aramid yarns or galvanized steel wire armour allow direct vertical probe suspension in sea cages, wells and stilling tubes.
Foil plus tinned copper braid screening protects low-level mV, 4–20 mA, SDI-12, RS-485 and optical DO signals from pump VFD noise.
Resists bio-fouling cleaning agents, saline splash, sunlight and −30/−40 °C winter freeze around open aquaculture tanks.
Submersible water-quality probe cables are designed for static/suspended immersion rather than high-speed machine drag chains.
Use CF211.PUR Encoder Chain CableConstruction
Shown: 02-250V6 Vented PUR Sensor (IEC 60770 & EN 50288 02-250V6 Vented Polyurethane Level Sensor Specification) featuring central atmospheric vent tube, 22/24 awg tinned copper sensor cores and subsea / marine outer protective sheath (4-layer construction).

| # | Layer | Material & reference |
|---|---|---|
| 1 | Central Atmospheric Vent Tube | Breather capillary tube for hydrostatic depth/level compensation |
| 2 | 22/24 AWG Tinned Copper Sensor Cores | Six color-coded conductors with High-stifiness polypropylene (PP) core insulation |
| 3 | 100% Al/PET Foil Electrostatic Shield | Laminated aluminum-polyester foil tape with drain wire |
| 4 | Subsea / Marine Outer Protective Sheath | Blue hydrolysis- & abrasion-resistant marine Polyurethane (PUR) outer sheath |
Built to IEC 60770 & EN 50288 02-250V6 Vented Polyurethane Level Sensor Specification with central atmospheric vent tube and subsea / marine outer protective sheath
Available on continuous export winch drums or factory-terminated with subsea wet-mate / mechanical sockets
Supplied with EN 10204 3.1 routine dielectric, conductor/optical continuity & hydrostatic qualification report
Technical data
Sizes
Manufactured to IEC 60770 & EN 50288 02-250V6 Vented Polyurethane Level Sensor Specification for subsea robotics, ROV umbilicals, marine aquaculture and offshore sensor applications.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Max. pulling kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| 02-250V6 Vented PUR Sensor Construction Schedule (−30…+80 °C) | |||||||
| 02-250V6 Vented PUR Sensor 2×2×0.50 mm² | 2 × 2 × 0.50 mm² (20 AWG) + Vent/Drain | Stranded SnCu + Foil/TCWB + Subsea PUR | 8.4 | 98 | 2.5 | 50 | |
| 02-250V6 Vented PUR Sensor 4×2×0.50 + 2×1.5 | 4 × 2 × 0.50 + 2 × 1.5 mm² Hybrid | Stranded SnCu + Individual/Overall Shield | 11.8 | 195 | 5.2 | 70 | |
| 02-250V6 Vented PUR Sensor 4×2×0.75 + 4×2.5 | 4 × 2 × 0.75 + 4 × 2.5 mm² Subsea | Stranded SnCu + Aramid/Armour + PUR | 15.2 | 360 | 12.0 | 95 | |
| Configuration | Max. DC R₂₀ Ω/km | Rating / Impedance / Load | Operating temp. |
|---|---|---|---|
| 2 × 2 × 0.50 mm² (20 AWG) + Vent/Drain | 39.00 | 300 V (4–20 mA / DO) | −30…+80 °C |
| 4 × 2 × 0.50 + 2 × 1.5 mm² Hybrid | 39.00 | 300 V (CTD / Multi-Sensor) | −30…+80 °C |
| 4 × 2 × 0.75 + 4 × 2.5 mm² Subsea | 26.00 | 300 V (ROV / Camera / LED) | −30…+80 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor DC resistance / OTDR optical & dimensional check (IEC 60770 & EN 50288 02-250V6 Vented Polyurethane Level Sensor Specification) | DC resistance at 20 °C, optical attenuation and wall thickness within IEC 60770 & EN 50288 02-250V6 Vented Polyurethane Level Sensor Specification limits | Every manufactured drum length |
| AC high-voltage dielectric & insulation resistance test (IEC 60770 & EN 50288 02-250V6 Vented Polyurethane Level Sensor Specification) | Zero dielectric breakdown and verified wet insulation resistance for 300 V rating | Every manufactured drum length |
| Sample tests | ||
| Hydrostatic pressure, tensile load & seawater immersion qualification (IEC 60770 & EN 50288 02-250V6 Vented Polyurethane Level Sensor Specification) | Verified hydrostatic pressure integrity, breaking load and flex endurance across −30…+80 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.