Contact
aquaculture feeder drag-chain & subsea robotic torsion cableUL AWM 20233 / VDE 0812300 V (-40 to +80 °C)Subsea / Marine Outer Protective She

CF211.PUR Shielded Feeder Encoder CableUL AWM 20233 / VDE 0812 — 300 V — -40 to +80 °C Subsea & Marine Cable

CF211.PUR Shielded Feeder Encoder Cable featuring stranded copper twisted pairs (4×2) and subsea / marine outer protective sheath (UL AWM 20233 / VDE 0812, 300 V, -40 to +80 °C, min. bend radius 7.5 × OD).

Water-resistant
EMC screen
Outdoor & humid
Approved
Order designation
CF211.PUR Feeder Encoder Chain 2×2×0.50 mm²
Outer Ø ≈
8.4 mm
Net weight ≈
98 kg/km
Max. pulling ≈
2.5 kN
Core / stranding
Stranded SnCu + Foil/TCWB + Subsea PUR
All sizes (3)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
300 V
Tested per UL AWM 20233 / VDE 0812
Operating temp.
−40…+80 °C
Subsea, deck & cold-water duty
Min. bend radius
7.5 × OD
Winch sheave, TMS & subsea routing
Core / conductor
Stranded Copper
Twisted pairs with Thermoplastic elastom
Outer protection
Subsea / Marine
Black hydrolysis- & abrasion-resistant m
Standard
UL AWM 20233 / V
VDE 0812 & UL 20233 CF211.PUR Shielded F

Typical values for this cable type, based on VDE 0812 & UL 20233 CF211.PUR Shielded Feeder Encoder Chain Specification — confirmed in the datasheet and quotation for your order.

Application fit

Is CF211.PUR Feeder Encoder Chain right for your machine?

CF211.PUR Shielded Feeder Encoder Cable featuring stranded copper twisted pairs (4×2) and subsea / marine outer protective sheath (UL AWM 20233 / VDE 0812, 300 V, -40 to +80 °C, min. bend radius 7.5 × OD).

Energy chain / drag chain

Suitable

Short-pitch Class 6 copper stranding and low-adhesion TPE/PUR jackets deliver multi-million-cycle life in horizontal and self-supporting d

Free-hanging vertical run

Suitable

Robotic torsion (RF-Torsion) and coiled spiral builds absorb ±180°/m to ±360°/m multi-axis twist on ROV pan-and-tilt and manipulator wrist

Immersion & wet locations

Suitable

Hydrolysis-, seawater-, fish-oil- and UV-resistant outer jackets operate reliably above open fish tanks and coastal feed tracks.

Switchgear & control cabinet wiring

Suitable

High-coverage tinned copper braided screens protect encoder, load-cell and servo signals from VFD interference.

Vertical / spreader reel

Not suitable

Drag-chain and robotic wrist cables are not designed for high-tension deep-ocean vertical lift winches.

Use RM0045 Heavy ROV Umbilical
Typical machinesIndustrial Automation CableAutomated Aquaculture Rail & Gantry Feeding SystemsSubsea ROV Electric Manipulator Wrists & Pan-Tilt UnitsHatchery Grading, Vaccination & Fish-Counting AutomationSeafood Cold-Storage & Automated Packaging Drag Chains

Construction

Layer by layer

Shown: CF211.PUR Feeder Encoder Chain (VDE 0812 & UL 20233 CF211.PUR Shielded Feeder Encoder Chain Specification) featuring stranded copper twisted pairs (4×2), copper wire braid emc screen and subsea / marine outer protective sheath (3-layer construction).

CF211.PUR Feeder Encoder Chain — stepped horizontal cutaway showing Stranded Copper Twisted Pairs (4×2) and Subsea / M
Layer cutaway
#LayerMaterial & reference
1Stranded Copper Twisted Pairs (4×2)Twisted pairs with Thermoplastic elastomer (TPE) core insulation
2Copper Wire Braid EMC ScreenHigh-coverage braided copper shield for EMI/VFD protection
3Subsea / Marine Outer Protective SheathBlack hydrolysis- & abrasion-resistant marine Polyurethane (PUR) outer sheath

CF211.PUR Feeder Encoder Chain — Standard Subsea & Marine Execution

Built to VDE 0812 & UL 20233 CF211.PUR Shielded Feeder Encoder Chain Specification with stranded copper twisted pairs (4×2) and subsea / marine outer protective sheath

CF211.PUR Feeder Encoder Chain — Custom Winch Length / Molded Termination

Available on continuous export winch drums or factory-terminated with subsea wet-mate / mechanical sockets

CF211.PUR Feeder Encoder Chain — Hydrostatic & Routine Certified

Supplied with EN 10204 3.1 routine dielectric, conductor/optical continuity & hydrostatic qualification report

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on VDE 0812 & UL 20233 CF211.PUR Shielded Feeder Encoder Chain Specification. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage / operating system
300 V (VDE 0812 & UL 20233 CF211.PUR Shielded Feeder Encoder Chain Specification)
Core / conductor construction
Stranded Copper Twisted Pairs (4×2) — Twisted pairs with Thermoplastic elastomer (TPE) core insulation
Primary dielectric / optical buffer
Copper Wire Braid EMC Screen — High-coverage braided copper shield for EMI/VFD protection

Thermal

Continuous operating temperature
−40…+80 °C (submerged seawater & topside deck service)
Hydrostatic & thermal cycling endurance
Verified cold-bend and wet dielectric stability across −40…+80 °C per VDE 0812 & UL 20233 CF211.PUR Shielded Feeder Encoder Chain Specification
Storage & transport temperature
−40…+80 °C on export wooden/steel cable drum

Mechanical

Outer jacket / sheath protection
Subsea / Marine Outer Protective Sheath — Black hydrolysis- & abrasion-resistant marine Polyurethane (PUR) outer sheath
Minimum bending radius
7.5 × OD
Reinforcement / screen / bedding layer
Copper Wire Braid EMC Screen — High-coverage braided copper shield for EMI/VFD protection

Resistance

Seawater, hydrolysis & oil resistance
Resistant to permanent seawater immersion, hydrolysis, hydraulic oil and bio-fouling per VDE 0812 & UL 20233 CF211.PUR Shielded Feeder Encoder Chain Specification
Hydrostatic pressure & water blocking
Radial and longitudinal water-blocking integrity verified per VDE 0812 & UL 20233 CF211.PUR Shielded Feeder Encoder Chain Specification
RoHS & REACH compliance
RoHS 2 (2011/65/EU + 2015/863) & REACH SVHC compliant

Reference standards

Governing standard
VDE 0812 & UL 20233 CF211.PUR Shielded Feeder Encoder Chain Specification
Subsea & conductor qualification standards
IEC 60228 / DNV-ST-E402 / ISO 13628-5 / IEC 60794 / EN 10204
Quality management & inspection
ISO 9001:2015 & EN 10204 3.1 factory routine inspection

Identification

Model designation
CF211.PUR Feeder Encoder Chain
Sheath colour & metre marking
Continuous metre-marked black outer finish (Subsea / Marine )
Customs tariff (HS)
8544.49 / 8544.60 / 8544.70

Sizes

3 standard CF211.PUR Feeder Encoder Chain configurations

Manufactured to VDE 0812 & UL 20233 CF211.PUR Shielded Feeder Encoder Chain Specification for subsea robotics, ROV umbilicals, marine aquaculture and offshore sensor applications.

Dimensions, tensile load & weights
Order designationConfigurationCore / strandingOuter Ø ≈
mm
Net weight ≈
kg/km
Max. pulling
kN ≈
Min. bend R
mm
Enquiry
CF211.PUR Feeder Encoder Chain Construction Schedule (−40…+80 °C)
CF211.PUR Feeder Encoder Chain 2×2×0.50 mm²2 × 2 × 0.50 mm² (20 AWG) + Vent/DrainStranded SnCu + Foil/TCWB + Subsea PUR8.4982.550
CF211.PUR Feeder Encoder Chain 4×2×0.50 + 2×1.54 × 2 × 0.50 + 2 × 1.5 mm² HybridStranded SnCu + Individual/Overall Shield11.81955.270
CF211.PUR Feeder Encoder Chain 4×2×0.75 + 4×2.54 × 2 × 0.75 + 4 × 2.5 mm² SubseaStranded SnCu + Aramid/Armour + PUR15.236012.095
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Custom core counts, optical fiber channels, wet-mate terminations and continuous winch lengths available per VDE 0812 & UL 20233 CF211.PUR Shielded Feeder Encoder Chain Specification.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
Conductor DC resistance / OTDR optical & dimensional check (VDE 0812 & UL 20233 CF211.PUR Shielded Feeder Encoder Chain Specification)DC resistance at 20 °C, optical attenuation and wall thickness within VDE 0812 & UL 20233 CF211.PUR Shielded Feeder Encoder Chain Specification limitsEvery manufactured drum length
AC high-voltage dielectric & insulation resistance test (VDE 0812 & UL 20233 CF211.PUR Shielded Feeder Encoder Chain Specification)Zero dielectric breakdown and verified wet insulation resistance for 300 V ratingEvery manufactured drum length
Sample tests
Hydrostatic pressure, tensile load & seawater immersion qualification (VDE 0812 & UL 20233 CF211.PUR Shielded Feeder Encoder Chain Specification)Verified hydrostatic pressure integrity, breaking load and flex endurance across −40…+80 °CType qualification & periodic lot audit

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

UL AWM 20233 / VDE 0812 CompliantEN 10204 3.1 Factory Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

TEBAOFLEX CF211.PUR Feeder Encoder Chain UL AWM 20233 / VDE 0812 300 V CE
Delivery form
Heavy-duty export fumigated wooden drums, steel winch reels or pre-terminated subsea assemblies
Standard lengths
500 m, 1,000 m, 3,000 m continuous winch lengths or custom cut-to-length subsea jumpers
MOQ
100 m (standard configurations) · 300 m (custom subsea builds)
Lead time
2–4 weeks ex-works
Incoterms
EXW, FCA, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-10-29
Updated
2026-10-29

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What governing standard and construction define CF211.PUR Feeder Encoder Chain (CF211.PUR Shielded Feeder Encoder Cable)?
CF211.PUR Feeder Encoder Chain (CF211.PUR Shielded Feeder Encoder Cable) is manufactured in accordance with VDE 0812 & UL 20233 CF211.PUR Shielded Feeder Encoder Chain Specification for 300 V subsea,ROV and marine aquaculture service over -40 to +80 °C. Its 3-layer construction comprises stranded copper twisted pairs (4×2), copper wire braid emc screen and subsea / marine outer protective sheath.
What is the minimum bending radius and operating temperature range for CF211.PUR Feeder Encoder Chain?
The minimum bending radius for CF211.PUR Feeder Encoder Chain is 7.5 × OD across its continuous operating temperature range of -40 to +80 °C, ensuring mechanical flex endurance and hydrostatic reliability in subsea winches, TMS cages and aquaculture installations.
How are the concentric layers of CF211.PUR Feeder Encoder Chain arranged from inside to outside?
From inside to outside, the construction sequence is: (01) Stranded Copper Twisted Pairs (4×2) — Twisted pairs with Thermoplastic elastomer (TPE) core insulation; (02) Copper Wire Braid EMC Screen — High-coverage braided copper shield for EMI/VFD protection; (03) Subsea / Marine Outer Protective Sheath — Black hydrolysis- & abrasion-resistant marine Polyurethane (PUR) outer sheath.
What factory test certificates are supplied with CF211.PUR Feeder Encoder Chain?
Every production drum of CF211.PUR Feeder Encoder Chain undergoes routine conductor DC resistance / optical OTDR continuity, AC high-voltage dielectric and dimensional testing per VDE 0812 & UL 20233 CF211.PUR Shielded Feeder Encoder Chain Specification, and is delivered with an EN 10204 3.1 factory test certificate.

Request a quote

Get an engineering quote for CF211.PUR Feeder Encoder Chain

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

CF211.PUR Feeder Encoder Chain CF211.PUR Shielded Feeder Encoder Cable

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote