Immersion & wet locations
Hydrolysis-resistant ether-grade PUR/TPU jackets, water-blocked cores and optional atmospheric vent tubes support permanent immersion.
Product
Inductive CYK11 Subsea Water Sensor Extension Cable featuring flexible stranded copper conductors (4 cores) and subsea / marine outer protective sheath (EN 50288 / IEC 61158, 300 V, -40 to +90 °C, min. bend radius 5 × OD).
Typical values for this cable type, based on EN 50288 CYK11 Inductive Digital Water Sensor Extension Cable Standard — confirmed in the datasheet and quotation for your order.
Application fit
Inductive CYK11 Subsea Water Sensor Extension Cable featuring flexible stranded copper conductors (4 cores) and subsea / marine outer protective sheath (EN 50288 / IEC 61158, 300 V, -40 to +90 °C, min. bend radius 5 × OD).
Hydrolysis-resistant ether-grade PUR/TPU jackets, water-blocked cores and optional atmospheric vent tubes support permanent immersion.
Integrated aramid yarns or galvanized steel wire armour allow direct vertical probe suspension in sea cages, wells and stilling tubes.
Foil plus tinned copper braid screening protects low-level mV, 4–20 mA, SDI-12, RS-485 and optical DO signals from pump VFD noise.
Resists bio-fouling cleaning agents, saline splash, sunlight and −30/−40 °C winter freeze around open aquaculture tanks.
Submersible water-quality probe cables are designed for static/suspended immersion rather than high-speed machine drag chains.
Use CF211.PUR Encoder Chain CableConstruction
Shown: Inductive CYK11 Sensor Cable (EN 50288 CYK11 Inductive Digital Water Sensor Extension Cable Standard) featuring flexible stranded copper conductors (4 cores), cross-linked elastomeric / polymer core insulation and subsea / marine outer protective sheath (4-layer construction).

| # | Layer | Material & reference |
|---|---|---|
| 1 | Flexible Stranded Copper Conductors (4 C | Class 5 / class 6 copper conductors |
| 2 | Cross-Linked Elastomeric / Polymer Core | Thermoplastic elastomer (tpe) core insulation |
| 3 | Water-Blocking Tape & Inner Bedding | Hydrostatic water-blocking filler and low-friction separator wrap |
| 4 | Subsea / Marine Outer Protective Sheath | Black chemical- & bio-oil-resistant thermoplastic elastomer (TPE) outer sheath |
Built to EN 50288 CYK11 Inductive Digital Water Sensor Extension Cable Standard with flexible stranded copper conductors (4 cores) and subsea / marine outer protective sheath
Available on continuous export winch drums or factory-terminated with subsea wet-mate / mechanical sockets
Supplied with EN 10204 3.1 routine dielectric, conductor/optical continuity & hydrostatic qualification report
Technical data
Sizes
Manufactured to EN 50288 CYK11 Inductive Digital Water Sensor Extension Cable Standard for subsea robotics, ROV umbilicals, marine aquaculture and offshore sensor applications.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Max. pulling kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| Inductive CYK11 Sensor Cable Construction Schedule (−40…+90 °C) | |||||||
| Inductive CYK11 Sensor Cable 1×2×22AWG RS-485 | 1 × 2 × 0.34 mm² (22 AWG) + Power Pair | Stranded SnCu + Foam PE + Foil/Braid | 8.2 | 92 | 2.0 | 50 | |
| Inductive CYK11 Sensor Cable 4×2×24AWG Cat5e | 4 × 2 × 24 AWG Subsea Gigabit Ethernet | Stranded SnCu + High-Pressure PE + SF/UTP | 9.6 | 125 | 3.5 | 60 | |
| Inductive CYK11 Sensor Cable 4×2×23AWG Cat6+2C | 4 × 2 × 23 AWG Cat6 + 2 × 1.5 mm² Power | Stranded SnCu + 600-Bar Matrix + PUR | 12.8 | 215 | 6.8 | 78 | |
| Configuration | Max. DC R₂₀ Ω/km | Rating / Impedance / Load | Operating temp. |
|---|---|---|---|
| 1 × 2 × 0.34 mm² (22 AWG) + Power Pair | 55.00 | 300 V (120 Ω RS-485) | −40…+90 °C |
| 4 × 2 × 24 AWG Subsea Gigabit Ethernet | 84.00 | 300 V (100 Ω 1000BASE-T) | −40…+90 °C |
| 4 × 2 × 23 AWG Cat6 + 2 × 1.5 mm² Power | 72.00 | 300 V (100 Ω Cat6 6000m) | −40…+90 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor DC resistance / OTDR optical & dimensional check (EN 50288 CYK11 Inductive Digital Water Sensor Extension Cable Standard) | DC resistance at 20 °C, optical attenuation and wall thickness within EN 50288 CYK11 Inductive Digital Water Sensor Extension Cable Standard limits | Every manufactured drum length |
| AC high-voltage dielectric & insulation resistance test (EN 50288 CYK11 Inductive Digital Water Sensor Extension Cable Standard) | Zero dielectric breakdown and verified wet insulation resistance for 300 V rating | Every manufactured drum length |
| Sample tests | ||
| Hydrostatic pressure, tensile load & seawater immersion qualification (EN 50288 CYK11 Inductive Digital Water Sensor Extension Cable Standard) | Verified hydrostatic pressure integrity, breaking load and flex endurance across −40…+90 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.