Contact
submersible water-quality, CTD & ocean sensor cableAPI RP 7G / DNV-ST-E4021,000 V (-40 to +105 °C)Double Torque-Balanced Steel Wire Ar

1HRS347 Armoured Borehole & Pipe CableAPI RP 7G / DNV-ST-E402 — 1,000 V — -40 to +105 °C Subsea & Marine Cable

1HRS347 Armoured Borehole & Pipe Cable featuring coaxial center conductor and double torque-balanced steel wire armour (API RP 7G / DNV-ST-E402, 1,000 V, -40 to +105 °C, min. bend radius 12 × OD).

Water-resistant
EMC screen
Outdoor & humid
Approved
Order designation
1HRS347 Armoured Borehole RG59/75Ω + 4C
Outer Ø ≈
10.8 mm
Net weight ≈
165 kg/km
Max. pulling ≈
8.5 kN
Core / stranding
SnCu Center + Foam PE + TCWB + Subsea PUR
All sizes (3)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
1,000 V
Tested per API RP 7G / DNV-ST-E402
Operating temp.
−40…+105 °C
Subsea, deck & cold-water duty
Min. bend radius
12 × OD
Winch sheave, TMS & subsea routing
Core / conductor
Coaxial Center C
High-conductivity stranded copper (or st
Outer protection
Double Torque-Ba
Contra-helical high-tensile galvanized s
Standard
API RP 7G / DNV-
API RP 7G & DNV 1HRS347 Double-Armoured

Typical values for this cable type, based on API RP 7G & DNV 1HRS347 Double-Armoured Subsea Borehole & Pipe Logging Standard — confirmed in the datasheet and quotation for your order.

Application fit

Is 1HRS347 Armoured Borehole/Pipe Cable right for your machine?

1HRS347 Armoured Borehole & Pipe Cable featuring coaxial center conductor and double torque-balanced steel wire armour (API RP 7G / DNV-ST-E402, 1,000 V, -40 to +105 °C, min. bend radius 12 × OD).

Immersion & wet locations

Suitable

Hydrolysis-resistant ether-grade PUR/TPU jackets, water-blocked cores and optional atmospheric vent tubes support permanent immersion.

Free-hanging vertical run

Suitable

Integrated aramid yarns or galvanized steel wire armour allow direct vertical probe suspension in sea cages, wells and stilling tubes.

Fixed installation

Suitable

Foil plus tinned copper braid screening protects low-level mV, 4–20 mA, SDI-12, RS-485 and optical DO signals from pump VFD noise.

Offshore platform & shipboard deck trays

Suitable

Resists bio-fouling cleaning agents, saline splash, sunlight and −30/−40 °C winter freeze around open aquaculture tanks.

Energy chain / drag chain

Not suitable

Submersible water-quality probe cables are designed for static/suspended immersion rather than high-speed machine drag chains.

Use CF211.PUR Encoder Chain Cable
Typical machinesUnderwater & Ocean ExplorationAquaculture Dissolved Oxygen (DO), pH & Salinity MonitoringVented Hydrostatic Water-Level & Borehole Pressure ProbesOceanographic CTD Rosettes, Current Meters & Mooring BuoysRecirculating Aquaculture (RAS) & Wastewater Sensor Networks

Construction

Layer by layer

Shown: 1HRS347 Armoured Borehole/Pipe Cable (API RP 7G & DNV 1HRS347 Double-Armoured Subsea Borehole & Pipe Logging Standard) featuring coaxial center conductor, low-loss coaxial dielectric & braid shield and double torque-balanced steel wire armour (4-layer construction).

1HRS347 Armoured Borehole/Pipe Cable — stepped horizontal cutaway showing Coaxial Center Conductor and Double Torque-B
Layer cutaway
#LayerMaterial & reference
1Coaxial Center ConductorHigh-conductivity stranded copper (or steel-core on CB 1900) center conductor
2Low-Loss Coaxial Dielectric & Braid ShieHigh-stifiness polypropylene (PP) core insulation + braided copper outer conductor
3Copper Wire Braid EMC ScreenHigh-coverage braided copper shield for EMI/VFD protection
4Double Torque-Balanced Steel Wire ArmourContra-helical high-tensile galvanized steel wire armour

1HRS347 Armoured Borehole/Pipe Cable — Standard Subsea & Marine Execution

Built to API RP 7G & DNV 1HRS347 Double-Armoured Subsea Borehole & Pipe Logging Standard with coaxial center conductor and double torque-balanced steel wire armour

1HRS347 Armoured Borehole/Pipe Cable — Custom Winch Length / Molded Termination

Available on continuous export winch drums or factory-terminated with subsea wet-mate / mechanical sockets

1HRS347 Armoured Borehole/Pipe Cable — Hydrostatic & Routine Certified

Supplied with EN 10204 3.1 routine dielectric, conductor/optical continuity & hydrostatic qualification report

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on API RP 7G & DNV 1HRS347 Double-Armoured Subsea Borehole & Pipe Logging Standard. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage / operating system
1,000 V (API RP 7G & DNV 1HRS347 Double-Armoured Subsea Borehole & Pipe Logging Standard)
Core / conductor construction
Coaxial Center Conductor — High-conductivity stranded copper (or steel-core on CB 1900) center conductor
Primary dielectric / optical buffer
Low-Loss Coaxial Dielectric & Braid Shield — High-stifiness polypropylene (PP) core insulation + braided copper outer conductor

Thermal

Continuous operating temperature
−40…+105 °C (submerged seawater & topside deck service)
Hydrostatic & thermal cycling endurance
Verified cold-bend and wet dielectric stability across −40…+105 °C per API RP 7G & DNV 1HRS347 Double-Armoured Subsea Borehole & Pipe Logging Standard
Storage & transport temperature
−40…+80 °C on export wooden/steel cable drum

Mechanical

Outer jacket / sheath protection
Double Torque-Balanced Steel Wire Armour — Contra-helical high-tensile galvanized steel wire armour
Minimum bending radius
12 × OD
Reinforcement / screen / bedding layer
Copper Wire Braid EMC Screen — High-coverage braided copper shield for EMI/VFD protection

Resistance

Seawater, hydrolysis & oil resistance
Resistant to permanent seawater immersion, hydrolysis, hydraulic oil and bio-fouling per API RP 7G & DNV 1HRS347 Double-Armoured Subsea Borehole & Pipe Logging Standard
Hydrostatic pressure & water blocking
Radial and longitudinal water-blocking integrity verified per API RP 7G & DNV 1HRS347 Double-Armoured Subsea Borehole & Pipe Logging Standard
RoHS & REACH compliance
RoHS 2 (2011/65/EU + 2015/863) & REACH SVHC compliant

Reference standards

Governing standard
API RP 7G & DNV 1HRS347 Double-Armoured Subsea Borehole & Pipe Logging Standard
Subsea & conductor qualification standards
IEC 60228 / DNV-ST-E402 / ISO 13628-5 / IEC 60794 / EN 10204
Quality management & inspection
ISO 9001:2015 & EN 10204 3.1 factory routine inspection

Identification

Model designation
1HRS347 Armoured Borehole/Pipe Cable
Sheath colour & metre marking
Continuous metre-marked black outer finish (Double Torque-Ba)
Customs tariff (HS)
8544.49 / 8544.60 / 8544.70

Sizes

3 standard 1HRS347 Armoured Borehole/Pipe Cable configurations

Manufactured to API RP 7G & DNV 1HRS347 Double-Armoured Subsea Borehole & Pipe Logging Standard for subsea robotics, ROV umbilicals, marine aquaculture and offshore sensor applications.

Dimensions, tensile load & weights
Order designationConfigurationCore / strandingOuter Ø ≈
mm
Net weight ≈
kg/km
Max. pulling
kN ≈
Min. bend R
mm
Enquiry
1HRS347 Armoured Borehole/Pipe Cable Construction Schedule (−40…+105 °C)
1HRS347 Armoured Borehole RG59/75Ω + 4C1×75 Ω Coax + 4×0.75 mm² (18 AWG)SnCu Center + Foam PE + TCWB + Subsea PUR10.81658.565
1HRS347 Armoured Borehole RG213/50Ω + 6C1×50/75 Ω Coax + 6×1.5 mm² + 1×TPSnCu + Dual Braid Shield + Aramid/GSWA14.434022.090
1HRS347 Armoured Borehole 3×Coax + 6C3×75 Ω Video Coax + 6×1.5 mm² PowerMulti-Coax Bundle + Armour + Subsea Jacket18.662048.0125
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Custom core counts, optical fiber channels, wet-mate terminations and continuous winch lengths available per API RP 7G & DNV 1HRS347 Double-Armoured Subsea Borehole & Pipe Logging Standard.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
Conductor DC resistance / OTDR optical & dimensional check (API RP 7G & DNV 1HRS347 Double-Armoured Subsea Borehole & Pipe Logging Standard)DC resistance at 20 °C, optical attenuation and wall thickness within API RP 7G & DNV 1HRS347 Double-Armoured Subsea Borehole & Pipe Logging Standard limitsEvery manufactured drum length
AC high-voltage dielectric & insulation resistance test (API RP 7G & DNV 1HRS347 Double-Armoured Subsea Borehole & Pipe Logging Standard)Zero dielectric breakdown and verified wet insulation resistance for 1,000 V ratingEvery manufactured drum length
Sample tests
Hydrostatic pressure, tensile load & seawater immersion qualification (API RP 7G & DNV 1HRS347 Double-Armoured Subsea Borehole & Pipe Logging Standard)Verified hydrostatic pressure integrity, breaking load and flex endurance across −40…+105 °CType qualification & periodic lot audit

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

API RP 7G / DNV-ST-E402 CompliantEN 10204 3.1 Factory Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

TEBAOFLEX 1HRS347 Armoured Borehole/Pipe Cable API RP 7G / DNV-ST-E402 1,000 V CE
Delivery form
Heavy-duty export fumigated wooden drums, steel winch reels or pre-terminated subsea assemblies
Standard lengths
500 m, 1,000 m, 3,000 m continuous winch lengths or custom cut-to-length subsea jumpers
MOQ
100 m (standard configurations) · 300 m (custom subsea builds)
Lead time
2–4 weeks ex-works
Incoterms
EXW, FCA, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-10-29
Updated
2026-10-29

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What governing standard and construction define 1HRS347 Armoured Borehole/Pipe Cable (1HRS347 Armoured Borehole & Pipe Cable)?
1HRS347 Armoured Borehole/Pipe Cable (1HRS347 Armoured Borehole & Pipe Cable) is manufactured in accordance with API RP 7G & DNV 1HRS347 Double-Armoured Subsea Borehole & Pipe Logging Standard for 1,000 V subsea,ROV and marine aquaculture service over -40 to +105 °C. Its 4-layer construction comprises coaxial center conductor, low-loss coaxial dielectric & braid shield and double torque-balanced steel wire armour.
What is the minimum bending radius and operating temperature range for 1HRS347 Armoured Borehole/Pipe Cable?
The minimum bending radius for 1HRS347 Armoured Borehole/Pipe Cable is 12 × OD across its continuous operating temperature range of -40 to +105 °C, ensuring mechanical flex endurance and hydrostatic reliability in subsea winches, TMS cages and aquaculture installations.
How are the concentric layers of 1HRS347 Armoured Borehole/Pipe Cable arranged from inside to outside?
From inside to outside, the construction sequence is: (01) Coaxial Center Conductor — High-conductivity stranded copper (or steel-core on CB 1900) center conductor; (02) Low-Loss Coaxial Dielectric & Braid Shield — High-stifiness polypropylene (PP) core insulation + braided copper outer conductor; (03) Copper Wire Braid EMC Screen — High-coverage braided copper shield for EMI/VFD protection; (04) Double Torque-Balanced Steel Wire Armour — Contra-helical high-tensile galvanized steel wire armour.
What factory test certificates are supplied with 1HRS347 Armoured Borehole/Pipe Cable?
Every production drum of 1HRS347 Armoured Borehole/Pipe Cable undergoes routine conductor DC resistance / optical OTDR continuity, AC high-voltage dielectric and dimensional testing per API RP 7G & DNV 1HRS347 Double-Armoured Subsea Borehole & Pipe Logging Standard, and is delivered with an EN 10204 3.1 factory test certificate.

Request a quote

Get an engineering quote for 1HRS347 Armoured Borehole/Pipe Cable

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

1HRS347 Armoured Borehole & Pipe Cable

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote