1HRS347 Armoured Borehole & Pipe Cable featuring coaxial center conductor and double torque-balanced steel wire armour (API RP 7G / DNV-ST-E402, 1,000 V, -40 to +105 °C, min. bend radius 12 × OD).
Typical values for this cable type, based on API RP 7G & DNV 1HRS347 Double-Armoured Subsea Borehole & Pipe Logging Standard — confirmed in the datasheet and quotation for your order.
Application fit
1HRS347 Armoured Borehole & Pipe Cable featuring coaxial center conductor and double torque-balanced steel wire armour (API RP 7G / DNV-ST-E402, 1,000 V, -40 to +105 °C, min. bend radius 12 × OD).
Hydrolysis-resistant ether-grade PUR/TPU jackets, water-blocked cores and optional atmospheric vent tubes support permanent immersion.
Integrated aramid yarns or galvanized steel wire armour allow direct vertical probe suspension in sea cages, wells and stilling tubes.
Foil plus tinned copper braid screening protects low-level mV, 4–20 mA, SDI-12, RS-485 and optical DO signals from pump VFD noise.
Resists bio-fouling cleaning agents, saline splash, sunlight and −30/−40 °C winter freeze around open aquaculture tanks.
Submersible water-quality probe cables are designed for static/suspended immersion rather than high-speed machine drag chains.
Use CF211.PUR Encoder Chain CableConstruction
Shown: 1HRS347 Armoured Borehole/Pipe Cable (API RP 7G & DNV 1HRS347 Double-Armoured Subsea Borehole & Pipe Logging Standard) featuring coaxial center conductor, low-loss coaxial dielectric & braid shield and double torque-balanced steel wire armour (4-layer construction).

| # | Layer | Material & reference |
|---|---|---|
| 1 | Coaxial Center Conductor | High-conductivity stranded copper (or steel-core on CB 1900) center conductor |
| 2 | Low-Loss Coaxial Dielectric & Braid Shie | High-stifiness polypropylene (PP) core insulation + braided copper outer conductor |
| 3 | Copper Wire Braid EMC Screen | High-coverage braided copper shield for EMI/VFD protection |
| 4 | Double Torque-Balanced Steel Wire Armour | Contra-helical high-tensile galvanized steel wire armour |
Built to API RP 7G & DNV 1HRS347 Double-Armoured Subsea Borehole & Pipe Logging Standard with coaxial center conductor and double torque-balanced steel wire armour
Available on continuous export winch drums or factory-terminated with subsea wet-mate / mechanical sockets
Supplied with EN 10204 3.1 routine dielectric, conductor/optical continuity & hydrostatic qualification report
Technical data
Sizes
Manufactured to API RP 7G & DNV 1HRS347 Double-Armoured Subsea Borehole & Pipe Logging Standard for subsea robotics, ROV umbilicals, marine aquaculture and offshore sensor applications.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Max. pulling kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| 1HRS347 Armoured Borehole/Pipe Cable Construction Schedule (−40…+105 °C) | |||||||
| 1HRS347 Armoured Borehole RG59/75Ω + 4C | 1×75 Ω Coax + 4×0.75 mm² (18 AWG) | SnCu Center + Foam PE + TCWB + Subsea PUR | 10.8 | 165 | 8.5 | 65 | |
| 1HRS347 Armoured Borehole RG213/50Ω + 6C | 1×50/75 Ω Coax + 6×1.5 mm² + 1×TP | SnCu + Dual Braid Shield + Aramid/GSWA | 14.4 | 340 | 22.0 | 90 | |
| 1HRS347 Armoured Borehole 3×Coax + 6C | 3×75 Ω Video Coax + 6×1.5 mm² Power | Multi-Coax Bundle + Armour + Subsea Jacket | 18.6 | 620 | 48.0 | 125 | |
| Configuration | Max. DC R₂₀ Ω/km | Rating / Impedance / Load | Operating temp. |
|---|---|---|---|
| 1×75 Ω Coax + 4×0.75 mm² (18 AWG) | 26.00 | 1,000 V · 75 Ω ±3 Ω | −40…+105 °C |
| 1×50/75 Ω Coax + 6×1.5 mm² + 1×TP | 13.30 | 1,000 V · 50/75 Ω Sonar | −40…+105 °C |
| 3×75 Ω Video Coax + 6×1.5 mm² Power | 13.30 | 1,000 V · 3-Ch 75 Ω Coax | −40…+105 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor DC resistance / OTDR optical & dimensional check (API RP 7G & DNV 1HRS347 Double-Armoured Subsea Borehole & Pipe Logging Standard) | DC resistance at 20 °C, optical attenuation and wall thickness within API RP 7G & DNV 1HRS347 Double-Armoured Subsea Borehole & Pipe Logging Standard limits | Every manufactured drum length |
| AC high-voltage dielectric & insulation resistance test (API RP 7G & DNV 1HRS347 Double-Armoured Subsea Borehole & Pipe Logging Standard) | Zero dielectric breakdown and verified wet insulation resistance for 1,000 V rating | Every manufactured drum length |
| Sample tests | ||
| Hydrostatic pressure, tensile load & seawater immersion qualification (API RP 7G & DNV 1HRS347 Double-Armoured Subsea Borehole & Pipe Logging Standard) | Verified hydrostatic pressure integrity, breaking load and flex endurance across −40…+105 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.