Mine roadway & tunnel wall hangers
Engineered for underground mining shafts, galleries and tunnel infrastructure per PN-EN 60794-1-2 / IEC 60332-3-22.
Product
Engineered for underground mining, open-cast excavation, shaft infrastructure and heavy industrial service per PN-EN 60794-1-2 / IEC 60332-3-22 across -40 to +70 °C.
Typical values for this cable type, based on PN-EN 60794-1-2 / IEC 60332-3-22 — confirmed in the datasheet and quotation for your order.
Application fit
Engineered for underground mining, open-cast excavation, shaft infrastructure and heavy industrial service per PN-EN 60794-1-2 / IEC 60332-3-22 across -40 to +70 °C.
Engineered for underground mining shafts, galleries and tunnel infrastructure per PN-EN 60794-1-2 / IEC 60332-3-22.
Suitable for vertical shaft cleats, gallery messenger hooks and tray routing within 15 × OD.
Supports inclined roadway and vertical mine shaft suspension within rated kN load across -40 to +70 °C.
Not optimized for high-speed overhead crane C-track festoon loops; select a dedicated festoon cable.
NGFLGÖU Flat Rubber Festoon CableConstruction
Shown: YOTKGtsFtZnyn (PN-EN 60794-1-2 / IEC 60332-3-22) featuring central frp rod (csm), loose buffer tubes (6×12f gts) and mining flame-retardant sheath (yn) (5-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | Central FRP Rod (CSM) | Dielectric Fiber-Reinforced Plastic central strength member |
| 2 | Loose Buffer Tubes (6×12F Gts) | SZ-stranded gel-filled PBT tubes (Red/Green marker + Natural tubes) |
| 3 | Water-Blocking Tape & Black Inner Sheath | Longitudinal swellable tape + black flame-retardant PVC inner bedding |
| 4 | Galvanized Steel Tape Armour (FtZn) | Double helically applied steel tapes (3500 N/100 mm crush resistance) |
| 5 | Mining Flame-Retardant Sheath (yn) | Blue IEC 60332-3-22 Cat. A flame-retardant mining PVC outer jacket |
Built to PN-EN 60794-1-2 / IEC 60332-3-22 with central frp rod (csm) and mining flame-retardant sheath (yn)
Available in custom shaft/roadway drum lengths or pre-terminated assemblies
Supplied with EN 10204 3.1 routine dielectric, resistance & flame test report
Technical data
Sizes
Manufactured to PN-EN 60794-1-2 / IEC 60332-3-22 for underground mining, open-cast excavation, shaft and heavy industrial systems.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Tensile rating kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| YOTKGtsFtZnyn Construction Schedule (-40 to +70 °C) | |||||||
| YOTKGtsFtZnyn 24J (6×4F) G.652.D | 24 × SM G.652.D (6×4F) | SZ gel-filled PBT tubes | 14.8 | 285 | 3.0 | 225 | |
| YOTKGtsFtZnyn 72J (6×12F) G.652.D | 72 × SM G.652.D (6×12F) | SZ gel-filled PBT tubes | 15.6 | 315 | 3.0 | 235 | |
| YOTKGtsFtZnyn 144J (12×12F) G.652.D | 144 × SM G.652.D (12×12F) | SZ gel-filled PBT tubes | 19.4 | 465 | 3.5 | 295 | |
| Configuration | Max. DC R₂₀ / Atten. Ω/km or dB/km | Rating / Impedance | Operating temp. |
|---|---|---|---|
| 24 × SM G.652.D (6×4F) | 0.36 | ≤0.22 dB/km @ 1550 nm | -40 to +70 °C |
| 72 × SM G.652.D (6×12F) | 0.36 | ≤0.22 dB/km @ 1550 nm | -40 to +70 °C |
| 144 × SM G.652.D (12×12F) | 0.36 | ≤0.22 dB/km @ 1550 nm | -40 to +70 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance, continuity & dimensional verification (PN-EN 60794-1-2 / IEC 60332-3-22) | DC resistance at 20 °C / optical attenuation and outer diameter within PN-EN 60794-1-2 / IEC 60332-3-22 tolerances | Every manufactured drum length |
| High-voltage dielectric & insulation resistance test (PN-EN 60794-1-2 / IEC 60332-3-22) | Zero dielectric breakdown and verified insulation resistance over full production length | Every manufactured drum length |
| Sample tests | ||
| Flame propagation, mechanical crush & thermal ageing qualification (PN-EN 60794-1-2 / IEC 60332-3-22) | Verified flame retardancy, mechanical integrity and thermal endurance across -40 to +70 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.