Mine roadway & tunnel wall hangers
Engineered for underground mining shafts, galleries and tunnel infrastructure per WT-TK-25 / TI EMAG / IEC 60332-3-24.
Product
Engineered for underground mining, open-cast excavation, shaft infrastructure and heavy industrial service per WT-TK-25 / TI EMAG / IEC 60332-3-24 across -30 to +70 °C.
Typical values for this cable type, based on WT-TK-25 / TI EMAG / IEC 60332-3-24 — confirmed in the datasheet and quotation for your order.
Application fit
Engineered for underground mining, open-cast excavation, shaft infrastructure and heavy industrial service per WT-TK-25 / TI EMAG / IEC 60332-3-24 across -30 to +70 °C.
Engineered for underground mining shafts, galleries and tunnel infrastructure per WT-TK-25 / TI EMAG / IEC 60332-3-24.
Suitable for vertical shaft cleats, gallery messenger hooks and tray routing within 12 × OD.
Supports inclined roadway and vertical mine shaft suspension within rated kN load across -30 to +70 °C.
Not optimized for high-speed overhead crane C-track festoon loops; select a dedicated festoon cable.
NGFLGÖU Flat Rubber Festoon CableConstruction
Shown: YHKGSYFoyn (WT-TK-25 / TI EMAG / IEC 60332-3-24) featuring screened signal cores (6×1.5 mm²), protective earth core (+1×1.5 żo) and ex-i blue outer sheath (yn) (5-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | Screened Signal Cores (6×1.5 mm²) | Class 1 solid bare copper + numbered PVC + individual tinned Cu braid (H) |
| 2 | Protective Earth Core (+1×1.5 żo) | Class 1 solid bare copper conductor with green/yellow PVC in outer layer |
| 3 | PVC Inner Bedding Sheath (Y) | Polyester tape wrap + extruded grey PVC inner cushioning sheath |
| 4 | Round Steel Wire Armour (Fo) | Galvanized round steel wire armour for ≤90° vertical mine shafts |
| 5 | Ex-i Blue Outer Sheath (yn) | RAL 5015 intrinsically safe high-LOI (LOI ≥ 29%) Cat. C mining PVC jacket |
Built to WT-TK-25 / TI EMAG / IEC 60332-3-24 with screened signal cores (6×1.5 mm²) and ex-i blue outer sheath (yn)
Available in custom shaft/roadway drum lengths or pre-terminated assemblies
Supplied with EN 10204 3.1 routine dielectric, resistance & flame test report
Technical data
Sizes
Manufactured to WT-TK-25 / TI EMAG / IEC 60332-3-24 for underground mining, open-cast excavation, shaft and heavy industrial systems.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Tensile rating kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| YHKGSYFoyn Construction Schedule (-30 to +70 °C) | |||||||
| YHKGSYFoynżo 4×1.5 + 1×1.5 mm² | 4 × 1.5 mm² (H) + 1 × 1.5 żo | Class 1 solid Cu + Round SWA | 18.6 | 640 | 8.5 | 225 | |
| YHKGSYFoynżo 6×1.5 + 1×1.5 mm² | 6 × 1.5 mm² (H) + 1 × 1.5 żo | Class 1 solid Cu + Round SWA | 21.2 | 830 | 11.0 | 255 | |
| YHKGSYFoynżo 12×1.5 + 1×1.5 mm² | 12 × 1.5 mm² (H) + 1 × 1.5 żo | Class 1 solid Cu + Round SWA | 26.8 | 1,320 | 16.5 | 320 | |
| Configuration | Max. DC R₂₀ / Atten. Ω/km or dB/km | Rating / Impedance | Operating temp. |
|---|---|---|---|
| 4 × 1.5 mm² (H) + 1 × 1.5 żo | 12.10 | 300/500 V · ≤90° vertical shaft | -30 to +70 °C |
| 6 × 1.5 mm² (H) + 1 × 1.5 żo | 12.10 | 300/500 V · ≤90° vertical shaft | -30 to +70 °C |
| 12 × 1.5 mm² (H) + 1 × 1.5 żo | 12.10 | 300/500 V · ≤90° vertical shaft | -30 to +70 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance, continuity & dimensional verification (WT-TK-25 / TI EMAG / IEC 60332-3-24) | DC resistance at 20 °C / optical attenuation and outer diameter within WT-TK-25 / TI EMAG / IEC 60332-3-24 tolerances | Every manufactured drum length |
| High-voltage dielectric & insulation resistance test (WT-TK-25 / TI EMAG / IEC 60332-3-24) | Zero dielectric breakdown and verified insulation resistance over full production length | Every manufactured drum length |
| Sample tests | ||
| Flame propagation, mechanical crush & thermal ageing qualification (WT-TK-25 / TI EMAG / IEC 60332-3-24) | Verified flame retardancy, mechanical integrity and thermal endurance across -30 to +70 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.