VFD inverter to AC motor screened feeder
Symmetrical low-impedance EMC design for PWM inverter motor and pump feeders per AS/NZS 5000.1 / AS/NZS 1125 / AS/NZS 3808.
Product
Engineered for underground mining, open-cast excavation, shaft infrastructure and heavy industrial service per AS/NZS 5000.1 / AS/NZS 1125 / AS/NZS 3808 across -25 to +90 °C.
Typical values for this cable type, based on AS/NZS 5000.1 / AS/NZS 1125 / AS/NZS 3808 — confirmed in the datasheet and quotation for your order.
Application fit
Engineered for underground mining, open-cast excavation, shaft infrastructure and heavy industrial service per AS/NZS 5000.1 / AS/NZS 1125 / AS/NZS 3808 across -25 to +90 °C.
Symmetrical low-impedance EMC design for PWM inverter motor and pump feeders per AS/NZS 5000.1 / AS/NZS 1125 / AS/NZS 3808.
Suitable for mining processing plants, slurry pumps and underground VFD drives (-25 to +90 °C).
Approved for cable tray, rack, conduit and trailing feeder routing within 12 × OD.
Not optimized for high-speed overhead crane C-track festoon loops; select a dedicated festoon cable.
NGFLGÖU Flat Rubber Festoon CableConstruction
Shown: VSD EMC 3C+3E (AS/NZS 5000.1 / AS/NZS 1125 / AS/NZS 3808) featuring phase conductors (3×95 mm²), x-90 xlpe phase insulation and outer sheath (black 5v-90 pvc) (5-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | Phase Conductors (3×95 mm²) | AS/NZS 1125 plain annealed copper (Class 2 standard or Class 5 flexible) |
| 2 | X-90 XLPE Phase Insulation | 90 °C crosslinked polyethylene color-coded Red, White & Blue |
| 3 | Symmetrical Tri-Earth Cores (3×16 mm²) | Three Green/Yellow X-90 insulated split earths in phase interstices |
| 4 | Black PVC Bedding & Copper Tape Screen | Extruded black PVC inner bedding + 100% helically lapped copper tape screen |
| 5 | Outer Sheath (Black 5V-90 PVC) | UV-stabilized, flame-retardant and oil-resistant black 5V-90 PVC jacket |
Built to AS/NZS 5000.1 / AS/NZS 1125 / AS/NZS 3808 with phase conductors (3×95 mm²) and outer sheath (black 5v-90 pvc)
Available in custom shaft/roadway drum lengths or pre-terminated assemblies
Supplied with EN 10204 3.1 routine dielectric, resistance & flame test report
Technical data
Sizes
Manufactured to AS/NZS 5000.1 / AS/NZS 1125 / AS/NZS 3808 for underground mining, open-cast excavation, shaft and heavy industrial systems.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Tensile rating kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| VSD EMC 3C+3E Construction Schedule (-25 to +90 °C) | |||||||
| VSD EMC 3C+3E 3×35 + 3×6 mm² | 3 × 35 mm² + 3 × 6 mm² (3E) | AS/NZS 1125 plain Cu | 26.8 | 1,520 | 18.0 | 320 | |
| VSD EMC 3C+3E 3×95 + 3×16 mm² | 3 × 95 mm² + 3 × 16 mm² (3E) | AS/NZS 1125 plain Cu | 39.2 | 3,740 | 48.0 | 470 | |
| VSD EMC 3C+3E 3×150 + 3×25 mm² | 3 × 150 mm² + 3 × 25 mm² (3E) | AS/NZS 1125 plain Cu | 47.5 | 5,680 | 75.0 | 570 | |
| Configuration | Max. DC R₂₀ / Atten. Ω/km or dB/km | Rating / Impedance | Operating temp. |
|---|---|---|---|
| 3 × 35 mm² + 3 × 6 mm² (3E) | 0.52 | 0.6/1 kV (158 A) | -25 to +90 °C |
| 3 × 95 mm² + 3 × 16 mm² (3E) | 0.19 | 0.6/1 kV (285 A) | -25 to +90 °C |
| 3 × 150 mm² + 3 × 25 mm² (3E) | 0.12 | 0.6/1 kV (365 A) | -25 to +90 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance, continuity & dimensional verification (AS/NZS 5000.1 / AS/NZS 1125 / AS/NZS 3808) | DC resistance at 20 °C / optical attenuation and outer diameter within AS/NZS 5000.1 / AS/NZS 1125 / AS/NZS 3808 tolerances | Every manufactured drum length |
| High-voltage dielectric & insulation resistance test (AS/NZS 5000.1 / AS/NZS 1125 / AS/NZS 3808) | Zero dielectric breakdown and verified insulation resistance over full production length | Every manufactured drum length |
| Sample tests | ||
| Flame propagation, mechanical crush & thermal ageing qualification (AS/NZS 5000.1 / AS/NZS 1125 / AS/NZS 3808) | Verified flame retardancy, mechanical integrity and thermal endurance across -25 to +90 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.