VFD inverter to AC motor screened feeder
Symmetrical 3+3 split grounds or 100% foil + 85% tinned copper braid shield give a low-impedance return path for PWM drive currents.
Product
UL Type WTTC 1,000 V / UL 1277 TC-ER 600 V Class K 85% Tinned-Copper Braid Shielded Wind Turbine Tray & Drive Cable (UL 2277 WTTC / UL 1277 TC-ER, 1,000 V WTTC / 600 V TC-ER, -40 to +90 °C, min. bend radius 6 × OD).
Typical values for this cable type, based on UL Subject 2277 Type WTTC 1,000 V & UL 1277 TC-ER 85% TCWB Shielded Drive Specification — confirmed in the datasheet and quotation for your order.
Application fit
UL Type WTTC 1,000 V / UL 1277 TC-ER 600 V Class K 85% Tinned-Copper Braid Shielded Wind Turbine Tray & Drive Cable (UL 2277 WTTC / UL 1277 TC-ER, 1,000 V WTTC / 600 V TC-ER, -40 to +90 °C, min. bend radius 6 × OD).
Symmetrical 3+3 split grounds or 100% foil + 85% tinned copper braid shield give a low-impedance return path for PWM drive currents.
Extra-thick 2XL XLPE / RHW-2 insulation withstands high dV/dt voltage spikes and corona discharge from IGBT wind converters.
Class 5 / Class K flexible copper conductors and −40 °C TPE/CPE/PVC jackets handle nacelle vibration, tray routing and drip-loop torsion.
Dual-listed to UL Subject 2277 Type WTTC (1,000 V), UL 1277 TC-ER (600 V) and UL 44 RHW-2 (2,000 V) for raceway-free nacelle installation.
Wind converter VFD feeder cable is not designed for continuous mobile reeling drums.
Use Spreader Reel CableConstruction
Shown: UL WTTC 1000V Braid-Shielded Tray (UL Subject 2277 Type WTTC 1,000 V & UL 1277 TC-ER 85% TCWB Shielded Drive Specification) featuring class k fine stranded bare copper (14–2 awg), pvc / nylon composite core insulation and cold & oil-resistant pvc outer jacket (4-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | Class K Fine Stranded Bare Copper (14–2 | Extra-flexible rope-lay plain copper conductors |
| 2 | PVC / Nylon Composite Core Insulation | 1,000 V UL WTTC and 600 V TC-ER rated insulation |
| 3 | 85% Coverage Tinned Copper Braid Shield | Flexible braided tinned copper screen for pitch & auxiliary drives |
| 4 | Cold & Oil-Resistant PVC Outer Jacket | Exposed-Run (TC-ER) & WTTC approved nacelle tray sheath |
Built to UL Subject 2277 Type WTTC 1,000 V & UL 1277 TC-ER 85% TCWB Shielded Drive Specification with class k fine stranded bare copper (14–2 awg) and cold & oil-resistant pvc outer jacket
Available on bulk export reels or pre-cut to turbine tower section and nacelle drip-loop lengths
Supplied with EN 10204 3.1 routine dielectric, conductor DC resistance & cold-torsion qualification report
Technical data
Sizes
Manufactured to UL Subject 2277 Type WTTC 1,000 V & UL 1277 TC-ER 85% TCWB Shielded Drive Specification for wind turbine yaw drip-loop, pitch control, tower power and converter applications.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Max. pulling kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| UL WTTC 1000V Braid-Shielded Tray Construction Schedule (−40…+90 °C) | |||||||
| UL WTTC 1000V Braid-Shielded Tray 4G16 / 3×16+3G | 4G16 mm² (or 3×6 AWG + 3G10 AWG) | IEC 60228 Class 5 / Class K Cu | 21.8 | 790 | 9.5 | 130 | |
| UL WTTC 1000V Braid-Shielded Tray 4G50 / 3×50+3G | 4G50 mm² (or 3×1 AWG + 3G6 AWG) | IEC 60228 Class 5 / Class K Cu | 31.4 | 2,140 | 22.5 | 190 | |
| UL WTTC 1000V Braid-Shielded Tray 3×150+3G25 VFD | 3×150 + 3G25 mm² (or 3×350 kcmil) | IEC 60228 Class 5 / Class K Cu | 47.2 | 5,480 | 58.0 | 285 | |
| Configuration | Max. DC R₂₀ Ω/km | Rating / Impedance | Operating temp. |
|---|---|---|---|
| 4G16 mm² (or 3×6 AWG + 3G10 AWG) | 1.15 | 1,000 V WTTC / 600 V TC-ER (98 A VFD) | −40…+90 °C |
| 4G50 mm² (or 3×1 AWG + 3G6 AWG) | 0.39 | 1,000 V WTTC / 600 V TC-ER (195 A VFD) | −40…+90 °C |
| 3×150 + 3G25 mm² (or 3×350 kcmil) | 0.13 | 1,000 V WTTC / 600 V TC-ER (395 A VFD) | −40…+90 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor DC resistance & dimensional verification (UL Subject 2277 Type WTTC 1,000 V & UL 1277 TC-ER 85% TCWB Shielded Drive Specification) | DC resistance at 20 °C and insulation/sheath wall thickness within UL Subject 2277 Type WTTC 1,000 V & UL 1277 TC-ER 85% TCWB Shielded Drive Specification limits | Every manufactured drum length |
| AC high-voltage dielectric & insulation resistance test (UL Subject 2277 Type WTTC 1,000 V & UL 1277 TC-ER 85% TCWB Shielded Drive Specification) | Zero dielectric breakdown and verified insulation resistance for 1,000 V WTTC / 600 V TC-ER rating | Every manufactured drum length |
| Sample tests | ||
| Low-temperature drip-loop torsion, oil & flame qualification (UL Subject 2277 Type WTTC 1,000 V & UL 1277 TC-ER 85% TCWB Shielded Drive Specification) | Verified cold torsion cycle endurance, oil resistance and flame retardancy across −40…+90 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.