Contact
wind turbine drip-loop, tray & pitch control cableUL 2277 WTTC / UL 1277 TC-ER1,000 V WTTC / 600 V TC-ER (-40 to +Cold & Oil-Resistant Torsion PVC Jac

UL Type WTTC 1,000 V / UL 1277 TC-ER 600 V Class K Unshielded Torsion Wind Turbine Tray CableUL 2277 WTTC / UL 1277 TC-ER — 1,000 V WTTC / 600 V TC-ER — -40 to +90 °C Wind Turbine Cable

UL Type WTTC 1,000 V / UL 1277 TC-ER 600 V Class K Unshielded Torsion Wind Turbine Tray Cable (UL 2277 WTTC / UL 1277 TC-ER) engineered for 1,000 V WTTC / 600 V TC-ER wind turbine service across -40 to +90 °C (min. bend radius 6 × OD).

Anti-torsion braid
Flame-retardant
Oil-resistant
Approved
Order designation
UL WTTC 1000V Unshielded Tray 7G1.5 mm²
Outer Ø ≈
11.4 mm
Net weight ≈
215 kg/km
Max. pulling ≈
2.4 kN
Core / stranding
IEC 60228 Class 5/6 / Class K Cu
All sizes (3)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
1,000 V WTTC / 6
Tested per UL 2277 WTTC / UL 1277 TC-ER
Operating temp.
−40…+90 °C
Cold-climate & nacelle wind service
Min. bend radius
6 × OD
Drip-loop, hub & tower routing
Core / conductor
Class K (30 AWG)
Extra-flexible rope-stranded plain coppe
Outer protection
Cold & Oil-Resis
Exposed-Run (ER) rated jacket for nacell
Standard
UL 2277 WTTC / U
UL Subject 2277 Type WTTC 1,000 V & UL 1

Typical values for this cable type, based on UL Subject 2277 Type WTTC 1,000 V & UL 1277 TC-ER 600 V Class K Tray Specification — confirmed in the datasheet and quotation for your order.

Application fit

Is UL WTTC 1000V Unshielded Tray right for your machine?

UL Type WTTC 1,000 V / UL 1277 TC-ER 600 V Class K Unshielded Torsion Wind Turbine Tray Cable (UL 2277 WTTC / UL 1277 TC-ER) engineered for 1,000 V WTTC / 600 V TC-ER wind turbine service across -40 to +90 °C (min. bend radius 6 × OD).

Free-hanging vertical run

Suitable

Class 5, Class 6 and Class K extra-flexible copper cores withstand continuous ±150°/m drip-loop and ±450°/0.5m pitch torsion down to −40/−

Fixed installation

Suitable

UL 2277 WTTC 1,000 V / UL 1277 TC-ER 600 V and IEC 0.6/1 kV ratings allow open tray and Exposed Run routing across the nacelle and tower.

Switchgear & control cabinet wiring

Suitable

Number-coded cores and 85% tinned copper braid / foil+braid shields terminate neatly into pitch servo boxes, slip-rings and PLC cabinets.

Energy chain / drag chain

Suitable

PUR-sheathed Class 6 pitch & slip-ring cables (RT 113/123, RT 114/116) handle combined rotary hub motion and bending.

Vertical / spreader reel

Not suitable

Wind turbine control and tray cable is not engineered for deepwater vertical oceanographic lift winches.

Use A304739 BOP MUX Umbilical
Typical machinesRenewable Energy & EV ChargingWind Turbine Rotor Hub Pitch Control & Slip-RingsNacelle-to-Tower Multi-Core Drip-Loop Control BundlesUL 2277 WTTC / TC-ER Nacelle & Tower Cable TraysBlade De-Icing, Trace Heating & Aviation Obstruction Lights

Construction

Layer by layer

Shown: UL WTTC 1000V Unshielded Tray (UL Subject 2277 Type WTTC 1,000 V & UL 1277 TC-ER 600 V Class K Tray Specification) featuring class k (30 awg) bare copper conductors (3–12 cores), pvc / nylon (thhn/thwn) core insulation and cold & oil-resistant torsion pvc jacket (-40 °c) (3-layer construction).

123
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1Class K (30 AWG) Bare Copper Conductors Extra-flexible rope-stranded plain copper (14 AWG to 10 AWG)
2PVC / Nylon (THHN/THWN) Core Insulation1,000 V WTTC & 600 V TC-ER numbered core insulation
3Cold & Oil-Resistant Torsion PVC Jacket Exposed-Run (ER) rated jacket for nacelle trays & drip loops

UL WTTC 1000V Unshielded Tray — Standard Wind Turbine Execution

Built to UL Subject 2277 Type WTTC 1,000 V & UL 1277 TC-ER 600 V Class K Tray Specification with class k (30 awg) bare copper conductors (3–12 cores) and cold & oil-resistant torsion pvc jacket (-40 °c)

UL WTTC 1000V Unshielded Tray — Pre-Cut Tower / Drip-Loop Kit

Available on bulk export reels or pre-cut to turbine tower section and nacelle drip-loop lengths

UL WTTC 1000V Unshielded Tray — Cold Torsion & Routine Certified

Supplied with EN 10204 3.1 routine dielectric, conductor DC resistance & cold-torsion qualification report

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on UL Subject 2277 Type WTTC 1,000 V & UL 1277 TC-ER 600 V Class K Tray Specification. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage / operating system
1,000 V WTTC / 600 V TC-ER (UL Subject 2277 Type WTTC 1,000 V & UL 1277 TC-ER 600 V Class K Tray Specification)
Core / conductor construction
Class K (30 AWG) Bare Copper Conductors (3–12 Cores) — Extra-flexible rope-stranded plain copper (14 AWG to 10 AWG)
Primary dielectric / insulation
PVC / Nylon (THHN/THWN) Core Insulation — 1,000 V WTTC & 600 V TC-ER numbered core insulation

Thermal

Continuous operating temperature
−40…+90 °C (wind turbine nacelle, hub & tower duty)
Low-temperature torsion & cold bend
Verified cold-flex and torsion endurance across −40…+90 °C per UL Subject 2277 Type WTTC 1,000 V & UL 1277 TC-ER 600 V Class K Tray Specification
Storage & transport temperature
−40…+80 °C on export wooden/steel cable drum

Mechanical

Outer jacket / sheath protection
Cold & Oil-Resistant Torsion PVC Jacket (-40 °C) — Exposed-Run (ER) rated jacket for nacelle trays & drip loops
Minimum bending radius
6 × OD
Intermediate screen / separator / core layer
PVC / Nylon (THHN/THWN) Core Insulation — 1,000 V WTTC & 600 V TC-ER numbered core insulation

Resistance

Oil, grease, ozone & UV resistance
Resistant to wind turbine gearbox oil, hydraulic fluid, ozone and UV weathering per UL Subject 2277 Type WTTC 1,000 V & UL 1277 TC-ER 600 V Class K Tray Specification
Flame retardancy & smoke/halogen emission
Flame-retardant and environmental performance verified per UL Subject 2277 Type WTTC 1,000 V & UL 1277 TC-ER 600 V Class K Tray Specification
RoHS & REACH compliance
RoHS 2 (2011/65/EU + 2015/863) & REACH SVHC compliant

Reference standards

Governing standard
UL Subject 2277 Type WTTC 1,000 V & UL 1277 TC-ER 600 V Class K Tray Specification
Conductor & flame/test standards
IEC 60228 / IEC 60332-1-2 & -3 / UL 2277 WTTC / EN 10204
Quality management & inspection
ISO 9001:2015 & EN 10204 3.1 factory routine inspection

Identification

Model designation
UL WTTC 1000V Unshielded Tray
Sheath colour & metre marking
Continuous metre-marked black outer finish (Cold & Oil-Resis)
Customs tariff (HS)
8544.49 / 8544.60

Sizes

3 standard UL WTTC 1000V Unshielded Tray wind turbine configurations

Manufactured to UL Subject 2277 Type WTTC 1,000 V & UL 1277 TC-ER 600 V Class K Tray Specification for wind turbine yaw drip-loop, pitch control, tower power and converter applications.

Dimensions, tensile load & weights
Order designationConfigurationCore / strandingOuter Ø ≈
mm
Net weight ≈
kg/km
Max. pulling
kN ≈
Min. bend R
mm
Enquiry
UL WTTC 1000V Unshielded Tray Construction Schedule (−40…+90 °C)
UL WTTC 1000V Unshielded Tray 7G1.5 mm²7G1.5 mm² (or 7C × 16 AWG)IEC 60228 Class 5/6 / Class K Cu11.42152.470
UL WTTC 1000V Unshielded Tray 12G1.5 mm²12G1.5 mm² (or 12C × 16 AWG)IEC 60228 Class 5/6 / Class K Cu14.83454.190
UL WTTC 1000V Unshielded Tray 18G2.5 mm²18G2.5 mm² (or 18C × 14 AWG)IEC 60228 Class 5/6 / Class K Cu19.66809.8120
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Custom conductor cross-sections, core counts, pre-lugged tower kits and drum lengths available per UL Subject 2277 Type WTTC 1,000 V & UL 1277 TC-ER 600 V Class K Tray Specification.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
Conductor DC resistance & dimensional verification (UL Subject 2277 Type WTTC 1,000 V & UL 1277 TC-ER 600 V Class K Tray Specification)DC resistance at 20 °C and insulation/sheath wall thickness within UL Subject 2277 Type WTTC 1,000 V & UL 1277 TC-ER 600 V Class K Tray Specification limitsEvery manufactured drum length
AC high-voltage dielectric & insulation resistance test (UL Subject 2277 Type WTTC 1,000 V & UL 1277 TC-ER 600 V Class K Tray Specification)Zero dielectric breakdown and verified insulation resistance for 1,000 V WTTC / 600 V TC-ER ratingEvery manufactured drum length
Sample tests
Low-temperature drip-loop torsion, oil & flame qualification (UL Subject 2277 Type WTTC 1,000 V & UL 1277 TC-ER 600 V Class K Tray Specification)Verified cold torsion cycle endurance, oil resistance and flame retardancy across −40…+90 °CType qualification & periodic lot audit

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

UL 2277 WTTC / UL 1277 TC-ER CompliantEN 10204 3.1 Factory Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

TEBAOFLEX UL WTTC 1000V Unshielded Tray UL 2277 WTTC / UL 1277 TC-ER 1,000 V WTTC / 600 V TC-ER CE
Delivery form
Heavy-duty export fumigated wooden drums, steel reels or pre-cut wind turbine tower & drip-loop kits
Standard lengths
500 m, 1,000 m or custom cut-to-length nacelle drip-loop and tower section sets
MOQ
100 m (standard configurations) · 300 m (custom wind builds)
Lead time
2–4 weeks ex-works
Incoterms
EXW, FCA, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-10-27
Updated
2026-10-27

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What governing standard and construction define UL WTTC 1000V Unshielded Tray (UL Type WTTC 1,000 V / UL 1277 TC-ER 600 V Class K Unshielded Torsion Wind Turbine Tray Cable)?
UL WTTC 1000V Unshielded Tray (UL Type WTTC 1,000 V / UL 1277 TC-ER 600 V Class K Unshielded Torsion Wind Turbine Tray Cable) is manufactured in accordance with UL Subject 2277 Type WTTC 1,000 V & UL 1277 TC-ER 600 V Class K Tray Specification for 1,000 V WTTC / 600 V TC-ER wind turbine service over -40 to +90 °C. Its 3-layer construction comprises class k (30 awg) bare copper conductors (3–12 cores), pvc / nylon (thhn/thwn) core insulation and cold & oil-resistant torsion pvc jacket (-40 °c).
What is the minimum bending radius and operating temperature range for UL WTTC 1000V Unshielded Tray?
The minimum bending radius for UL WTTC 1000V Unshielded Tray is 6 × OD across its continuous operating temperature range of -40 to +90 °C, ensuring mechanical torsion resistance and dielectric reliability in wind turbine nacelles, hubs and towers.
How are the concentric layers of UL WTTC 1000V Unshielded Tray arranged from inside to outside?
From inside to outside, the construction sequence is: (01) Class K (30 AWG) Bare Copper Conductors (3–12 Cores) — Extra-flexible rope-stranded plain copper (14 AWG to 10 AWG); (02) PVC / Nylon (THHN/THWN) Core Insulation — 1,000 V WTTC & 600 V TC-ER numbered core insulation; (03) Cold & Oil-Resistant Torsion PVC Jacket (-40 °C) — Exposed-Run (ER) rated jacket for nacelle trays & drip loops.
What factory test certificates are supplied with UL WTTC 1000V Unshielded Tray?
Every production drum of UL WTTC 1000V Unshielded Tray undergoes routine conductor DC resistance, AC high-voltage dielectric and dimensional testing per UL Subject 2277 Type WTTC 1,000 V & UL 1277 TC-ER 600 V Class K Tray Specification, and is delivered with an EN 10204 3.1 factory test certificate.

Request a quote

Get an engineering quote for UL WTTC 1000V Unshielded Tray

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

UL WTTC 1000V Unshielded Tray UL Type WTTC 1,000 V / UL 1277 TC-ER 600 V Class K Unshielded Torsion Wind Turbine Tray Cable

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp