Immersion & wet locations
Hydrolysis-resistant ether-grade PUR/TPU jackets, water-blocked cores and optional atmospheric vent tubes support permanent immersion.
Product
Type 4021CC Subsea Shielded Data Cable featuring stranded copper twisted pairs (4×2) and subsea / marine outer protective sheath (DNV-ST-E402 / IEC 60092-376, 300/600 V, -40 to +80 °C, min. bend radius 6 × OD).
Typical values for this cable type, based on DNV-ST-E402 & IEC 60092-376 Type 4021CC Subsea Shielded Data Specification — confirmed in the datasheet and quotation for your order.
Application fit
Type 4021CC Subsea Shielded Data Cable featuring stranded copper twisted pairs (4×2) and subsea / marine outer protective sheath (DNV-ST-E402 / IEC 60092-376, 300/600 V, -40 to +80 °C, min. bend radius 6 × OD).
Hydrolysis-resistant ether-grade PUR/TPU jackets, water-blocked cores and optional atmospheric vent tubes support permanent immersion.
Integrated aramid yarns or galvanized steel wire armour allow direct vertical probe suspension in sea cages, wells and stilling tubes.
Foil plus tinned copper braid screening protects low-level mV, 4–20 mA, SDI-12, RS-485 and optical DO signals from pump VFD noise.
Resists bio-fouling cleaning agents, saline splash, sunlight and −30/−40 °C winter freeze around open aquaculture tanks.
Submersible water-quality probe cables are designed for static/suspended immersion rather than high-speed machine drag chains.
Use CF211.PUR Encoder Chain CableConstruction
Shown: Type 4021CC Subsea Data (DNV-ST-E402 & IEC 60092-376 Type 4021CC Subsea Shielded Data Specification) featuring stranded copper twisted pairs (4×2), low-capacitance core insulation and subsea / marine outer protective sheath (4-layer construction).

| # | Layer | Material & reference |
|---|---|---|
| 1 | Stranded Copper Twisted Pairs (4×2) | Twisted pairs |
| 2 | Low-Capacitance Core Insulation | High-stifiness polypropylene (pp) core insulation |
| 3 | Foil Screen & Water-Blocking Separator | 100% Al/PET foil electrostatic screen with water-blocking binder tape |
| 4 | Subsea / Marine Outer Protective Sheath | Black hydrolysis- & abrasion-resistant marine Polyurethane (PUR) outer sheath |
Built to DNV-ST-E402 & IEC 60092-376 Type 4021CC Subsea Shielded Data Specification with stranded copper twisted pairs (4×2) and subsea / marine outer protective sheath
Available on continuous export winch drums or factory-terminated with subsea wet-mate / mechanical sockets
Supplied with EN 10204 3.1 routine dielectric, conductor/optical continuity & hydrostatic qualification report
Technical data
Sizes
Manufactured to DNV-ST-E402 & IEC 60092-376 Type 4021CC Subsea Shielded Data Specification for subsea robotics, ROV umbilicals, marine aquaculture and offshore sensor applications.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Max. pulling kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| Type 4021CC Subsea Data Construction Schedule (−40…+80 °C) | |||||||
| Type 4021CC Subsea Data 2×2×0.50 mm² | 2 × 2 × 0.50 mm² (20 AWG) + Vent/Drain | Stranded SnCu + Foil/TCWB + Subsea PUR | 8.4 | 98 | 2.5 | 50 | |
| Type 4021CC Subsea Data 4×2×0.50 + 2×1.5 | 4 × 2 × 0.50 + 2 × 1.5 mm² Hybrid | Stranded SnCu + Individual/Overall Shield | 11.8 | 195 | 5.2 | 70 | |
| Type 4021CC Subsea Data 4×2×0.75 + 4×2.5 | 4 × 2 × 0.75 + 4 × 2.5 mm² Subsea | Stranded SnCu + Aramid/Armour + PUR | 15.2 | 360 | 12.0 | 95 | |
| Configuration | Max. DC R₂₀ Ω/km | Rating / Impedance / Load | Operating temp. |
|---|---|---|---|
| 2 × 2 × 0.50 mm² (20 AWG) + Vent/Drain | 39.00 | 300/600 V (4–20 mA / DO) | −40…+80 °C |
| 4 × 2 × 0.50 + 2 × 1.5 mm² Hybrid | 39.00 | 300/600 V (CTD / Multi-Sensor) | −40…+80 °C |
| 4 × 2 × 0.75 + 4 × 2.5 mm² Subsea | 26.00 | 300/600 V (ROV / Camera / LED) | −40…+80 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor DC resistance / OTDR optical & dimensional check (DNV-ST-E402 & IEC 60092-376 Type 4021CC Subsea Shielded Data Specification) | DC resistance at 20 °C, optical attenuation and wall thickness within DNV-ST-E402 & IEC 60092-376 Type 4021CC Subsea Shielded Data Specification limits | Every manufactured drum length |
| AC high-voltage dielectric & insulation resistance test (DNV-ST-E402 & IEC 60092-376 Type 4021CC Subsea Shielded Data Specification) | Zero dielectric breakdown and verified wet insulation resistance for 300/600 V rating | Every manufactured drum length |
| Sample tests | ||
| Hydrostatic pressure, tensile load & seawater immersion qualification (DNV-ST-E402 & IEC 60092-376 Type 4021CC Subsea Shielded Data Specification) | Verified hydrostatic pressure integrity, breaking load and flex endurance across −40…+80 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.