Immersion & wet locations
Hydrolysis-resistant ether-grade PUR/TPU jackets, water-blocked cores and optional atmospheric vent tubes support permanent immersion.
Product
Type 624637 Optical DO Probe Power Cable featuring flexible stranded copper conductors (4 cores) and subsea / marine outer protective sheath (EN 50288 / IEC 61010, 300 V, -30 to +85 °C, min. bend radius 5 × OD).
Typical values for this cable type, based on EN 50288 Type 624637 Optical Dissolved Oxygen Probe Cable Specification — confirmed in the datasheet and quotation for your order.
Application fit
Type 624637 Optical DO Probe Power Cable featuring flexible stranded copper conductors (4 cores) and subsea / marine outer protective sheath (EN 50288 / IEC 61010, 300 V, -30 to +85 °C, min. bend radius 5 × OD).
Hydrolysis-resistant ether-grade PUR/TPU jackets, water-blocked cores and optional atmospheric vent tubes support permanent immersion.
Integrated aramid yarns or galvanized steel wire armour allow direct vertical probe suspension in sea cages, wells and stilling tubes.
Foil plus tinned copper braid screening protects low-level mV, 4–20 mA, SDI-12, RS-485 and optical DO signals from pump VFD noise.
Resists bio-fouling cleaning agents, saline splash, sunlight and −30/−40 °C winter freeze around open aquaculture tanks.
Submersible water-quality probe cables are designed for static/suspended immersion rather than high-speed machine drag chains.
Use CF211.PUR Encoder Chain CableConstruction
Shown: Type 624637 Optical DO Cable (EN 50288 Type 624637 Optical Dissolved Oxygen Probe Cable Specification) featuring flexible stranded copper conductors (4 cores), cross-linked elastomeric / polymer core insulation and subsea / marine outer protective sheath (4-layer construction).

| # | Layer | Material & reference |
|---|---|---|
| 1 | Flexible Stranded Copper Conductors (4 C | Class 5 / class 6 copper conductors |
| 2 | Cross-Linked Elastomeric / Polymer Core | High-stifiness polypropylene (pp) core insulation |
| 3 | Water-Blocking Tape & Inner Bedding | Hydrostatic water-blocking filler and low-friction separator wrap |
| 4 | Subsea / Marine Outer Protective Sheath | Black hydrolysis- & abrasion-resistant marine Polyurethane (PUR) outer sheath |
Built to EN 50288 Type 624637 Optical Dissolved Oxygen Probe Cable Specification with flexible stranded copper conductors (4 cores) and subsea / marine outer protective sheath
Available on continuous export winch drums or factory-terminated with subsea wet-mate / mechanical sockets
Supplied with EN 10204 3.1 routine dielectric, conductor/optical continuity & hydrostatic qualification report
Technical data
Sizes
Manufactured to EN 50288 Type 624637 Optical Dissolved Oxygen Probe Cable Specification for subsea robotics, ROV umbilicals, marine aquaculture and offshore sensor applications.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Max. pulling kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| Type 624637 Optical DO Cable Construction Schedule (−30…+85 °C) | |||||||
| Type 624637 Optical DO Cable 2×2×0.50 mm² | 2 × 2 × 0.50 mm² (20 AWG) + Vent/Drain | Stranded SnCu + Foil/TCWB + Subsea PUR | 8.4 | 98 | 2.5 | 50 | |
| Type 624637 Optical DO Cable 4×2×0.50 + 2×1.5 | 4 × 2 × 0.50 + 2 × 1.5 mm² Hybrid | Stranded SnCu + Individual/Overall Shield | 11.8 | 195 | 5.2 | 70 | |
| Type 624637 Optical DO Cable 4×2×0.75 + 4×2.5 | 4 × 2 × 0.75 + 4 × 2.5 mm² Subsea | Stranded SnCu + Aramid/Armour + PUR | 15.2 | 360 | 12.0 | 95 | |
| Configuration | Max. DC R₂₀ Ω/km | Rating / Impedance / Load | Operating temp. |
|---|---|---|---|
| 2 × 2 × 0.50 mm² (20 AWG) + Vent/Drain | 39.00 | 300 V (4–20 mA / DO) | −30…+85 °C |
| 4 × 2 × 0.50 + 2 × 1.5 mm² Hybrid | 39.00 | 300 V (CTD / Multi-Sensor) | −30…+85 °C |
| 4 × 2 × 0.75 + 4 × 2.5 mm² Subsea | 26.00 | 300 V (ROV / Camera / LED) | −30…+85 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor DC resistance / OTDR optical & dimensional check (EN 50288 Type 624637 Optical Dissolved Oxygen Probe Cable Specification) | DC resistance at 20 °C, optical attenuation and wall thickness within EN 50288 Type 624637 Optical Dissolved Oxygen Probe Cable Specification limits | Every manufactured drum length |
| AC high-voltage dielectric & insulation resistance test (EN 50288 Type 624637 Optical Dissolved Oxygen Probe Cable Specification) | Zero dielectric breakdown and verified wet insulation resistance for 300 V rating | Every manufactured drum length |
| Sample tests | ||
| Hydrostatic pressure, tensile load & seawater immersion qualification (EN 50288 Type 624637 Optical Dissolved Oxygen Probe Cable Specification) | Verified hydrostatic pressure integrity, breaking load and flex endurance across −30…+85 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.