Contact
submersible water-quality, CTD & ocean sensor cableDNV-ST-E402 / MIL-DTL-24643600 V (-40 to +80 °C)Subsea / Marine Outer Protective She

TCS Stock Subsea Instrumentation CableDNV-ST-E402 / MIL-DTL-24643 — 600 V — -40 to +80 °C Subsea & Marine Cable

TCS Stock Subsea Instrumentation Cable featuring stranded copper twisted pairs (4×2) and subsea / marine outer protective sheath (DNV-ST-E402 / MIL-DTL-24643, 600 V, -40 to +80 °C, min. bend radius 6 × OD).

Water-resistant
EMC screen
Outdoor & humid
Approved
Order designation
TCS Stock Subsea Instrumentation 2×2×0.50 mm²
Outer Ø ≈
8.4 mm
Net weight ≈
98 kg/km
Max. pulling ≈
2.5 kN
Core / stranding
Stranded SnCu + Foil/TCWB + Subsea PUR
All sizes (3)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
600 V
Tested per DNV-ST-E402 / MIL-DTL-24643
Operating temp.
−40…+80 °C
Subsea, deck & cold-water duty
Min. bend radius
6 × OD
Winch sheave, TMS & subsea routing
Core / conductor
Stranded Copper
Twisted pairs with Cross-linked polyethy
Outer protection
Subsea / Marine
Black hydrolysis- & abrasion-resistant m
Standard
DNV-ST-E402 / MI
DNV-ST-E402 TCS Stock Subsea Shielded In

Typical values for this cable type, based on DNV-ST-E402 TCS Stock Subsea Shielded Instrumentation Cable Specification — confirmed in the datasheet and quotation for your order.

Application fit

Is TCS Stock Subsea Instrumentation right for your machine?

TCS Stock Subsea Instrumentation Cable featuring stranded copper twisted pairs (4×2) and subsea / marine outer protective sheath (DNV-ST-E402 / MIL-DTL-24643, 600 V, -40 to +80 °C, min. bend radius 6 × OD).

Immersion & wet locations

Suitable

Hydrolysis-resistant ether-grade PUR/TPU jackets, water-blocked cores and optional atmospheric vent tubes support permanent immersion.

Free-hanging vertical run

Suitable

Integrated aramid yarns or galvanized steel wire armour allow direct vertical probe suspension in sea cages, wells and stilling tubes.

Fixed installation

Suitable

Foil plus tinned copper braid screening protects low-level mV, 4–20 mA, SDI-12, RS-485 and optical DO signals from pump VFD noise.

Offshore platform & shipboard deck trays

Suitable

Resists bio-fouling cleaning agents, saline splash, sunlight and −30/−40 °C winter freeze around open aquaculture tanks.

Energy chain / drag chain

Not suitable

Submersible water-quality probe cables are designed for static/suspended immersion rather than high-speed machine drag chains.

Use CF211.PUR Encoder Chain Cable
Typical machinesUnderwater & Ocean ExplorationAquaculture Dissolved Oxygen (DO), pH & Salinity MonitoringVented Hydrostatic Water-Level & Borehole Pressure ProbesOceanographic CTD Rosettes, Current Meters & Mooring BuoysRecirculating Aquaculture (RAS) & Wastewater Sensor Networks

Construction

Layer by layer

Shown: TCS Stock Subsea Instrumentation (DNV-ST-E402 TCS Stock Subsea Shielded Instrumentation Cable Specification) featuring stranded copper twisted pairs (4×2), 100% al/pet foil electrostatic shield and subsea / marine outer protective sheath (3-layer construction).

TCS Stock Subsea Instrumentation — stepped horizontal cutaway showing Stranded Copper Twisted Pairs (4×2) and Subsea /
Layer cutaway
#LayerMaterial & reference
1Stranded Copper Twisted Pairs (4×2)Twisted pairs with Cross-linked polyethylene (XLPE) insulation
2100% Al/PET Foil Electrostatic ShieldLaminated aluminum-polyester foil tape with drain wire
3Subsea / Marine Outer Protective SheathBlack hydrolysis- & abrasion-resistant marine Polyurethane (PUR) outer sheath

TCS Stock Subsea Instrumentation — Standard Subsea & Marine Execution

Built to DNV-ST-E402 TCS Stock Subsea Shielded Instrumentation Cable Specification with stranded copper twisted pairs (4×2) and subsea / marine outer protective sheath

TCS Stock Subsea Instrumentation — Custom Winch Length / Molded Termination

Available on continuous export winch drums or factory-terminated with subsea wet-mate / mechanical sockets

TCS Stock Subsea Instrumentation — Hydrostatic & Routine Certified

Supplied with EN 10204 3.1 routine dielectric, conductor/optical continuity & hydrostatic qualification report

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on DNV-ST-E402 TCS Stock Subsea Shielded Instrumentation Cable Specification. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage / operating system
600 V (DNV-ST-E402 TCS Stock Subsea Shielded Instrumentation Cable Specification)
Core / conductor construction
Stranded Copper Twisted Pairs (4×2) — Twisted pairs with Cross-linked polyethylene (XLPE) insulation
Primary dielectric / optical buffer
100% Al/PET Foil Electrostatic Shield — Laminated aluminum-polyester foil tape with drain wire

Thermal

Continuous operating temperature
−40…+80 °C (submerged seawater & topside deck service)
Hydrostatic & thermal cycling endurance
Verified cold-bend and wet dielectric stability across −40…+80 °C per DNV-ST-E402 TCS Stock Subsea Shielded Instrumentation Cable Specification
Storage & transport temperature
−40…+80 °C on export wooden/steel cable drum

Mechanical

Outer jacket / sheath protection
Subsea / Marine Outer Protective Sheath — Black hydrolysis- & abrasion-resistant marine Polyurethane (PUR) outer sheath
Minimum bending radius
6 × OD
Reinforcement / screen / bedding layer
100% Al/PET Foil Electrostatic Shield — Laminated aluminum-polyester foil tape with drain wire

Resistance

Seawater, hydrolysis & oil resistance
Resistant to permanent seawater immersion, hydrolysis, hydraulic oil and bio-fouling per DNV-ST-E402 TCS Stock Subsea Shielded Instrumentation Cable Specification
Hydrostatic pressure & water blocking
Radial and longitudinal water-blocking integrity verified per DNV-ST-E402 TCS Stock Subsea Shielded Instrumentation Cable Specification
RoHS & REACH compliance
RoHS 2 (2011/65/EU + 2015/863) & REACH SVHC compliant

Reference standards

Governing standard
DNV-ST-E402 TCS Stock Subsea Shielded Instrumentation Cable Specification
Subsea & conductor qualification standards
IEC 60228 / DNV-ST-E402 / ISO 13628-5 / IEC 60794 / EN 10204
Quality management & inspection
ISO 9001:2015 & EN 10204 3.1 factory routine inspection

Identification

Model designation
TCS Stock Subsea Instrumentation
Sheath colour & metre marking
Continuous metre-marked black outer finish (Subsea / Marine )
Customs tariff (HS)
8544.49 / 8544.60 / 8544.70

Sizes

3 standard TCS Stock Subsea Instrumentation configurations

Manufactured to DNV-ST-E402 TCS Stock Subsea Shielded Instrumentation Cable Specification for subsea robotics, ROV umbilicals, marine aquaculture and offshore sensor applications.

Dimensions, tensile load & weights
Order designationConfigurationCore / strandingOuter Ø ≈
mm
Net weight ≈
kg/km
Max. pulling
kN ≈
Min. bend R
mm
Enquiry
TCS Stock Subsea Instrumentation Construction Schedule (−40…+80 °C)
TCS Stock Subsea Instrumentation 2×2×0.50 mm²2 × 2 × 0.50 mm² (20 AWG) + Vent/DrainStranded SnCu + Foil/TCWB + Subsea PUR8.4982.550
TCS Stock Subsea Instrumentation 4×2×0.50 + 2×1.4 × 2 × 0.50 + 2 × 1.5 mm² HybridStranded SnCu + Individual/Overall Shield11.81955.270
TCS Stock Subsea Instrumentation 4×2×0.75 + 4×2.4 × 2 × 0.75 + 4 × 2.5 mm² SubseaStranded SnCu + Aramid/Armour + PUR15.236012.095
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Custom core counts, optical fiber channels, wet-mate terminations and continuous winch lengths available per DNV-ST-E402 TCS Stock Subsea Shielded Instrumentation Cable Specification.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
Conductor DC resistance / OTDR optical & dimensional check (DNV-ST-E402 TCS Stock Subsea Shielded Instrumentation Cable Specification)DC resistance at 20 °C, optical attenuation and wall thickness within DNV-ST-E402 TCS Stock Subsea Shielded Instrumentation Cable Specification limitsEvery manufactured drum length
AC high-voltage dielectric & insulation resistance test (DNV-ST-E402 TCS Stock Subsea Shielded Instrumentation Cable Specification)Zero dielectric breakdown and verified wet insulation resistance for 600 V ratingEvery manufactured drum length
Sample tests
Hydrostatic pressure, tensile load & seawater immersion qualification (DNV-ST-E402 TCS Stock Subsea Shielded Instrumentation Cable Specification)Verified hydrostatic pressure integrity, breaking load and flex endurance across −40…+80 °CType qualification & periodic lot audit

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

DNV-ST-E402 / MIL-DTL-24643 CompliantEN 10204 3.1 Factory Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

TEBAOFLEX TCS Stock Subsea Instrumentation DNV-ST-E402 / MIL-DTL-24643 600 V CE
Delivery form
Heavy-duty export fumigated wooden drums, steel winch reels or pre-terminated subsea assemblies
Standard lengths
500 m, 1,000 m, 3,000 m continuous winch lengths or custom cut-to-length subsea jumpers
MOQ
100 m (standard configurations) · 300 m (custom subsea builds)
Lead time
2–4 weeks ex-works
Incoterms
EXW, FCA, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-10-29
Updated
2026-10-29

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What governing standard and construction define TCS Stock Subsea Instrumentation (TCS Stock Subsea Instrumentation Cable)?
TCS Stock Subsea Instrumentation (TCS Stock Subsea Instrumentation Cable) is manufactured in accordance with DNV-ST-E402 TCS Stock Subsea Shielded Instrumentation Cable Specification for 600 V subsea,ROV and marine aquaculture service over -40 to +80 °C. Its 3-layer construction comprises stranded copper twisted pairs (4×2), 100% al/pet foil electrostatic shield and subsea / marine outer protective sheath.
What is the minimum bending radius and operating temperature range for TCS Stock Subsea Instrumentation?
The minimum bending radius for TCS Stock Subsea Instrumentation is 6 × OD across its continuous operating temperature range of -40 to +80 °C, ensuring mechanical flex endurance and hydrostatic reliability in subsea winches, TMS cages and aquaculture installations.
How are the concentric layers of TCS Stock Subsea Instrumentation arranged from inside to outside?
From inside to outside, the construction sequence is: (01) Stranded Copper Twisted Pairs (4×2) — Twisted pairs with Cross-linked polyethylene (XLPE) insulation; (02) 100% Al/PET Foil Electrostatic Shield — Laminated aluminum-polyester foil tape with drain wire; (03) Subsea / Marine Outer Protective Sheath — Black hydrolysis- & abrasion-resistant marine Polyurethane (PUR) outer sheath.
What factory test certificates are supplied with TCS Stock Subsea Instrumentation?
Every production drum of TCS Stock Subsea Instrumentation undergoes routine conductor DC resistance / optical OTDR continuity, AC high-voltage dielectric and dimensional testing per DNV-ST-E402 TCS Stock Subsea Shielded Instrumentation Cable Specification, and is delivered with an EN 10204 3.1 factory test certificate.

Request a quote

Get an engineering quote for TCS Stock Subsea Instrumentation

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

TCS Stock Subsea Instrumentation Cable

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote