Immersion & wet locations
Cross-linked submersible elastomer compound is qualified for continuous deep-well, potable-water or sewage immersion.
Product
TML Type B (TML Round Type B / TML Flat Type B / TML T-RD / TML T-F) 450/750V & 0.6/1kV Potable Water Submersible Pump Motor Cable (VDE 0282-16 / EM6, 0.6/1 kV, -25 °C to +80 °C, min. bend radius 6 × OD).
Typical values for this cable type, based on DIN VDE 0282-16 / EN 50363-2-1 EM6 / KTW / W270 / ACS — confirmed in the datasheet and quotation for your order.
Application fit
TML Type B (TML Round Type B / TML Flat Type B / TML T-RD / TML T-F) 450/750V & 0.6/1kV Potable Water Submersible Pump Motor Cable (VDE 0282-16 / EM6, 0.6/1 kV, -25 °C to +80 °C, min. bend radius 6 × OD).
Cross-linked submersible elastomer compound is qualified for continuous deep-well, potable-water or sewage immersion.
High-modulus conductor and elastomer construction supports vertical suspension in deep boreholes and pump risers.
Tear- and abrasion-resistant rubber outer sheath handles mobile dewatering, dredger and portable pump deployment.
Suitable for permanent wet-well, treatment tank, geothermal borehole and submergedmanifold installations.
Submersible rubber pump cable is not intended for high-acceleration automation drag chains.
Use Drag-Chain Control CableConstruction
Shown: TML TYPE B (TML-B ROUND / FLAT) (DIN VDE 0282-16 / EN 50363-2-1 EM6 / KTW / W270 / ACS) featuring class 5 flexible conductors (4g16 mm²), water-resistant epr insulation (3gi3 / ei6) and food-grade blue epdm sheath (em6 / 3g357) (4-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | Class 5 Flexible Conductors (4G16 mm²) | DIN EN 60228 Class 5 finely stranded plain (or tinned) annealed copper |
| 2 | Water-Resistant EPR Insulation (3GI3 / EI6) | Low-water-absorption cross-linked EPR color-coded Brown, Black, Grey & Green/Yellow |
| 3 | Non-Toxic Central Filler & Separator | Food-grade central rubber dummy filler + polyester separator tape |
| 4 | Food-Grade Blue EPDM Sheath (EM6 / 3G357) | Peroxide-crosslinked potable-water EPDM sheath (ELL/KTW, DVGW W270 & ACS certified) |
Built to DIN VDE 0282-16 / EN 50363-2-1 EM6 / KTW / W270 / ACS with class 5 flexible conductors (4g16 mm²) and food-grade blue epdm sheath (em6 / 3g357)
Available in custom continuous subsea/wellbore drum lengths or pre-terminated assemblies
Supplied with EN 10204 3.1 routine dielectric, resistance & pressure/dimensional report
Technical data
Sizes
Manufactured to DIN VDE 0282-16 / EN 50363-2-1 EM6 / KTW / W270 / ACS for subsea, offshore, deep-well and marine applications.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Tensile rating kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| TML TYPE B (TML-B ROUND / FLAT) Construction Schedule (−25…+80 °C) | |||||||
| TML TYPE B 4G16 mm² | 4G16 mm² (3×16 + 1G16) | IEC 60228 Class 5 flexible Cu/SnCu | 21.8 | 840 | 2.4 | 130 | |
| TML TYPE B 4G35 mm² | 4G35 mm² (3×35 + 1G16) | IEC 60228 Class 5 flexible Cu/SnCu | 28.6 | 1,620 | 5.2 | 172 | |
| TML TYPE B 3×70 + 3G16 mm² | 3 × 70 mm² + 3G16 mm² | IEC 60228 Class 5 flexible Cu/SnCu | 38.4 | 3,180 | 10.5 | 230 | |
| Configuration | Max. DC R₂₀ / Atten. Ω/km or dB/km | Rating / Impedance | Operating temp. |
|---|---|---|---|
| 4G16 mm² (3×16 + 1G16) | 1.21 | 0.6/1 kV (94 A submerged) | −25…+80 °C |
| 4G35 mm² (3×35 + 1G16) | 0.55 | 0.6/1 kV (152 A submerged) | −25…+80 °C |
| 3 × 70 mm² + 3G16 mm² | 0.27 | 0.6/1 kV (235 A submerged) | −25…+80 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance, continuity & dimensional verification (DIN VDE 0282-16 / EN 50363-2-1 EM6 / KTW / W270 / ACS) | DC resistance at 20 °C / optical attenuation and outer diameter within DIN VDE 0282-16 / EN 50363-2-1 EM6 / KTW / W270 / ACS tolerances | Every manufactured drum length |
| High-voltage dielectric & insulation resistance test (DIN VDE 0282-16 / EN 50363-2-1 EM6 / KTW / W270 / ACS) | Zero dielectric breakdown and verified insulation resistance for 0.6/1 kV rating | Every manufactured drum length |
| Sample tests | ||
| Hydrostatic pressure, water-blocking & mechanical endurance qualification (DIN VDE 0282-16 / EN 50363-2-1 EM6 / KTW / W270 / ACS) | Verified submersion integrity, tensile load and thermal stability across −25…+80 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.