Contact
submersible water-quality, CTD & ocean sensor cableIEC 60092-376 / UL AWM300 V (-40 to +85 °C)Subsea / Marine Outer Protective She

Shielded TPE/PUR Harsh-Environment Sensor CableIEC 60092-376 / UL AWM — 300 V — -40 to +85 °C Subsea & Marine Cable

Shielded TPE/PUR Harsh-Environment Sensor Cable featuring coaxial center conductor and subsea / marine outer protective sheath (IEC 60092-376 / UL AWM, 300 V, -40 to +85 °C, min. bend radius 6 × OD).

Water-resistant
EMC screen
Outdoor & humid
Approved
Order designation
Shielded TPE RG59/75Ω + 4C
Outer Ø ≈
10.8 mm
Net weight ≈
165 kg/km
Max. pulling ≈
8.5 kN
Core / stranding
SnCu Center + Foam PE + TCWB + Subsea PUR
All sizes (3)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
300 V
Tested per IEC 60092-376 / UL AWM
Operating temp.
−40…+85 °C
Subsea, deck & cold-water duty
Min. bend radius
6 × OD
Winch sheave, TMS & subsea routing
Core / conductor
Coaxial Center C
High-conductivity stranded copper (or st
Outer protection
Subsea / Marine
Black hydrolysis- & abrasion-resistant m
Standard
IEC 60092-376 /
IEC 60092-376 Shielded TPE/PUR Harsh-Env

Typical values for this cable type, based on IEC 60092-376 Shielded TPE/PUR Harsh-Environment Subsea Sensor Specification — confirmed in the datasheet and quotation for your order.

Application fit

Is Shielded TPE/PUR Sensor right for your machine?

Shielded TPE/PUR Harsh-Environment Sensor Cable featuring coaxial center conductor and subsea / marine outer protective sheath (IEC 60092-376 / UL AWM, 300 V, -40 to +85 °C, min. bend radius 6 × OD).

Immersion & wet locations

Suitable

Hydrolysis-resistant ether-grade PUR/TPU jackets, water-blocked cores and optional atmospheric vent tubes support permanent immersion.

Free-hanging vertical run

Suitable

Integrated aramid yarns or galvanized steel wire armour allow direct vertical probe suspension in sea cages, wells and stilling tubes.

Fixed installation

Suitable

Foil plus tinned copper braid screening protects low-level mV, 4–20 mA, SDI-12, RS-485 and optical DO signals from pump VFD noise.

Offshore platform & shipboard deck trays

Suitable

Resists bio-fouling cleaning agents, saline splash, sunlight and −30/−40 °C winter freeze around open aquaculture tanks.

Energy chain / drag chain

Not suitable

Submersible water-quality probe cables are designed for static/suspended immersion rather than high-speed machine drag chains.

Use CF211.PUR Encoder Chain Cable
Typical machinesUnderwater & Ocean ExplorationAquaculture Dissolved Oxygen (DO), pH & Salinity MonitoringVented Hydrostatic Water-Level & Borehole Pressure ProbesOceanographic CTD Rosettes, Current Meters & Mooring BuoysRecirculating Aquaculture (RAS) & Wastewater Sensor Networks

Construction

Layer by layer

Shown: Shielded TPE/PUR Sensor (IEC 60092-376 Shielded TPE/PUR Harsh-Environment Subsea Sensor Specification) featuring coaxial center conductor, low-loss coaxial dielectric & braid shield and subsea / marine outer protective sheath (3-layer construction).

Shielded TPE/PUR Sensor — stepped horizontal cutaway showing Coaxial Center Conductor and Subsea / Marine Outer Protec
Layer cutaway
#LayerMaterial & reference
1Coaxial Center ConductorHigh-conductivity stranded copper (or steel-core on CB 1900) center conductor
2Low-Loss Coaxial Dielectric & Braid ShieThermoplastic elastomer (TPE) core insulation + braided copper outer conductor
3Subsea / Marine Outer Protective SheathBlack hydrolysis- & abrasion-resistant marine Polyurethane (PUR) outer sheath

Shielded TPE/PUR Sensor — Standard Subsea & Marine Execution

Built to IEC 60092-376 Shielded TPE/PUR Harsh-Environment Subsea Sensor Specification with coaxial center conductor and subsea / marine outer protective sheath

Shielded TPE/PUR Sensor — Custom Winch Length / Molded Termination

Available on continuous export winch drums or factory-terminated with subsea wet-mate / mechanical sockets

Shielded TPE/PUR Sensor — Hydrostatic & Routine Certified

Supplied with EN 10204 3.1 routine dielectric, conductor/optical continuity & hydrostatic qualification report

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on IEC 60092-376 Shielded TPE/PUR Harsh-Environment Subsea Sensor Specification. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage / operating system
300 V (IEC 60092-376 Shielded TPE/PUR Harsh-Environment Subsea Sensor Specification)
Core / conductor construction
Coaxial Center Conductor — High-conductivity stranded copper (or steel-core on CB 1900) center conductor
Primary dielectric / optical buffer
Low-Loss Coaxial Dielectric & Braid Shield — Thermoplastic elastomer (TPE) core insulation + braided copper outer conductor

Thermal

Continuous operating temperature
−40…+85 °C (submerged seawater & topside deck service)
Hydrostatic & thermal cycling endurance
Verified cold-bend and wet dielectric stability across −40…+85 °C per IEC 60092-376 Shielded TPE/PUR Harsh-Environment Subsea Sensor Specification
Storage & transport temperature
−40…+80 °C on export wooden/steel cable drum

Mechanical

Outer jacket / sheath protection
Subsea / Marine Outer Protective Sheath — Black hydrolysis- & abrasion-resistant marine Polyurethane (PUR) outer sheath
Minimum bending radius
6 × OD
Reinforcement / screen / bedding layer
Low-Loss Coaxial Dielectric & Braid Shield — Thermoplastic elastomer (TPE) core insulation + braided copper outer conductor

Resistance

Seawater, hydrolysis & oil resistance
Resistant to permanent seawater immersion, hydrolysis, hydraulic oil and bio-fouling per IEC 60092-376 Shielded TPE/PUR Harsh-Environment Subsea Sensor Specification
Hydrostatic pressure & water blocking
Radial and longitudinal water-blocking integrity verified per IEC 60092-376 Shielded TPE/PUR Harsh-Environment Subsea Sensor Specification
RoHS & REACH compliance
RoHS 2 (2011/65/EU + 2015/863) & REACH SVHC compliant

Reference standards

Governing standard
IEC 60092-376 Shielded TPE/PUR Harsh-Environment Subsea Sensor Specification
Subsea & conductor qualification standards
IEC 60228 / DNV-ST-E402 / ISO 13628-5 / IEC 60794 / EN 10204
Quality management & inspection
ISO 9001:2015 & EN 10204 3.1 factory routine inspection

Identification

Model designation
Shielded TPE/PUR Sensor
Sheath colour & metre marking
Continuous metre-marked black outer finish (Subsea / Marine )
Customs tariff (HS)
8544.49 / 8544.60 / 8544.70

Sizes

3 standard Shielded TPE/PUR Sensor configurations

Manufactured to IEC 60092-376 Shielded TPE/PUR Harsh-Environment Subsea Sensor Specification for subsea robotics, ROV umbilicals, marine aquaculture and offshore sensor applications.

Dimensions, tensile load & weights
Order designationConfigurationCore / strandingOuter Ø ≈
mm
Net weight ≈
kg/km
Max. pulling
kN ≈
Min. bend R
mm
Enquiry
Shielded TPE/PUR Sensor Construction Schedule (−40…+85 °C)
Shielded TPE RG59/75Ω + 4C1×75 Ω Coax + 4×0.75 mm² (18 AWG)SnCu Center + Foam PE + TCWB + Subsea PUR10.81658.565
Shielded TPE RG213/50Ω + 6C1×50/75 Ω Coax + 6×1.5 mm² + 1×TPSnCu + Dual Braid Shield + Aramid/GSWA14.434022.090
Shielded TPE 3×Coax + 6C3×75 Ω Video Coax + 6×1.5 mm² PowerMulti-Coax Bundle + Armour + Subsea Jacket18.662048.0125
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Custom core counts, optical fiber channels, wet-mate terminations and continuous winch lengths available per IEC 60092-376 Shielded TPE/PUR Harsh-Environment Subsea Sensor Specification.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
Conductor DC resistance / OTDR optical & dimensional check (IEC 60092-376 Shielded TPE/PUR Harsh-Environment Subsea Sensor Specification)DC resistance at 20 °C, optical attenuation and wall thickness within IEC 60092-376 Shielded TPE/PUR Harsh-Environment Subsea Sensor Specification limitsEvery manufactured drum length
AC high-voltage dielectric & insulation resistance test (IEC 60092-376 Shielded TPE/PUR Harsh-Environment Subsea Sensor Specification)Zero dielectric breakdown and verified wet insulation resistance for 300 V ratingEvery manufactured drum length
Sample tests
Hydrostatic pressure, tensile load & seawater immersion qualification (IEC 60092-376 Shielded TPE/PUR Harsh-Environment Subsea Sensor Specification)Verified hydrostatic pressure integrity, breaking load and flex endurance across −40…+85 °CType qualification & periodic lot audit

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

IEC 60092-376 / UL AWM CompliantEN 10204 3.1 Factory Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

TEBAOFLEX Shielded TPE/PUR Sensor IEC 60092-376 / UL AWM 300 V CE
Delivery form
Heavy-duty export fumigated wooden drums, steel winch reels or pre-terminated subsea assemblies
Standard lengths
500 m, 1,000 m, 3,000 m continuous winch lengths or custom cut-to-length subsea jumpers
MOQ
100 m (standard configurations) · 300 m (custom subsea builds)
Lead time
2–4 weeks ex-works
Incoterms
EXW, FCA, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-10-29
Updated
2026-10-29

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What governing standard and construction define Shielded TPE/PUR Sensor (Shielded TPE/PUR Harsh-Environment Sensor Cable)?
Shielded TPE/PUR Sensor (Shielded TPE/PUR Harsh-Environment Sensor Cable) is manufactured in accordance with IEC 60092-376 Shielded TPE/PUR Harsh-Environment Subsea Sensor Specification for 300 V subsea,ROV and marine aquaculture service over -40 to +85 °C. Its 3-layer construction comprises coaxial center conductor, low-loss coaxial dielectric & braid shield and subsea / marine outer protective sheath.
What is the minimum bending radius and operating temperature range for Shielded TPE/PUR Sensor?
The minimum bending radius for Shielded TPE/PUR Sensor is 6 × OD across its continuous operating temperature range of -40 to +85 °C, ensuring mechanical flex endurance and hydrostatic reliability in subsea winches, TMS cages and aquaculture installations.
How are the concentric layers of Shielded TPE/PUR Sensor arranged from inside to outside?
From inside to outside, the construction sequence is: (01) Coaxial Center Conductor — High-conductivity stranded copper (or steel-core on CB 1900) center conductor; (02) Low-Loss Coaxial Dielectric & Braid Shield — Thermoplastic elastomer (TPE) core insulation + braided copper outer conductor; (03) Subsea / Marine Outer Protective Sheath — Black hydrolysis- & abrasion-resistant marine Polyurethane (PUR) outer sheath.
What factory test certificates are supplied with Shielded TPE/PUR Sensor?
Every production drum of Shielded TPE/PUR Sensor undergoes routine conductor DC resistance / optical OTDR continuity, AC high-voltage dielectric and dimensional testing per IEC 60092-376 Shielded TPE/PUR Harsh-Environment Subsea Sensor Specification, and is delivered with an EN 10204 3.1 factory test certificate.

Request a quote

Get an engineering quote for Shielded TPE/PUR Sensor

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

Shielded TPE/PUR Harsh-Environment Sensor Cable

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote