Immersion & wet locations
Water-blocked core matrix and hydrolysis-resistant subsea jacketing withstand continuous deepwater hydrostatic pressure.
Product
Cable Systems 6/10 kV to 72.5 kV (and up to 132 kV Wet-Design) Dynamic & Static Subsea Boosting, Multiphase Pump (MPP) & ESP Power and Electro-Hydraulic Control Umbilical (API Spec 17E / ISO 13628-5, 19/33 kV, -20 °C to +90 °C).
Typical values for this cable type, based on API Spec 17E / ISO 13628-5 / IEC 60502-2 Subsea Boosting — confirmed in the datasheet and quotation for your order.
Application fit
Cable Systems 6/10 kV to 72.5 kV (and up to 132 kV Wet-Design) Dynamic & Static Subsea Boosting, Multiphase Pump (MPP) & ESP Power and Electro-Hydraulic Control Umbilical (API Spec 17E / ISO 13628-5, 19/33 kV, -20 °C to +90 °C).
Water-blocked core matrix and hydrolysis-resistant subsea jacketing withstand continuous deepwater hydrostatic pressure.
Torque-balanced aramid or contra-helical steel armour supports vertical winch deployment without hockling.
Marine-grade outer sheath and armour package resist LARS sheave abrasion, UV exposure and salt-spray corrosion.
High tensile breaking strength supports underwater towing, ROV excursion and seabed plough/trencher duty.
Subsea umbilical and tow construction is not intended for high-cycle indoor factory drag chains.
Use Drag-Chain Servo CableConstruction
Shown: SUBSEA BOOSTING & ESP UMBILICAL (API Spec 17E / ISO 13628-5 / IEC 60502-2 Subsea Boosting) featuring mv/hv vfd power cores (6/10–72.5 kv), 15,000–20,000 psi barrier fluid hoses and custom-stiffness dynamic hdpe jacket (5-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | MV/HV VFD Power Cores (6/10–72.5 kV) | Longitudinally water-blocked Cu/Al + triple-extruded EPR/XLPE + Cu screen + HDPE sheath |
| 2 | 15,000–20,000 PSI Barrier Fluid Hoses | Aramid-reinforced HP/HT thermoplastic hoses / SDSS tubes for pump seal barrier fluid |
| 3 | Armoured Fiber-Optic & Control Units | Steel-tube armoured single-mode optical cable + screened control pairs/quads |
| 4 | Profiled Fillers & Contra-Helical Armour | High-modulus profiled polymeric fillers + double torque-balanced galvanized steel armour |
| 5 | Custom-Stiffness Dynamic HDPE Jacket | Extruded abrasion-resistant HDPE / PUR outer sheath engineered for dynamic risers |
Built to API Spec 17E / ISO 13628-5 / IEC 60502-2 Subsea Boosting with mv/hv vfd power cores (6/10–72.5 kv) and custom-stiffness dynamic hdpe jacket
Available in custom continuous subsea/wellbore drum lengths or pre-terminated assemblies
Supplied with EN 10204 3.1 routine dielectric, resistance & pressure/dimensional report
Technical data
Sizes
Manufactured to API Spec 17E / ISO 13628-5 / IEC 60502-2 Subsea Boosting for subsea, offshore, deep-well and marine applications.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Tensile rating kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| SUBSEA BOOSTING & ESP UMBILICAL Construction Schedule (−20…+90 °C) | |||||||
| SUBSEA BOOSTING 3×240 mm² + FO | 3 × 240 mm² + 48F FIMT | IEC 60228 Class 2 water-blocked Cu | 118.0 | 26,400 | 320.0 | 1,770 | |
| SUBSEA BOOSTING 3×400 mm² + FO | 3 × 400 mm² + 48F FIMT | IEC 60228 Class 2 water-blocked Cu | 134.0 | 34,800 | 420.0 | 2,010 | |
| SUBSEA BOOSTING 3×630 mm² + FO | 3 × 630 mm² + 96F FIMT | IEC 60228 Class 2 water-blocked Cu | 152.0 | 46,200 | 560.0 | 2,280 | |
| Configuration | Max. DC R₂₀ / Atten. Ω/km or dB/km | Rating / Impedance | Operating temp. |
|---|---|---|---|
| 3 × 240 mm² + 48F FIMT | 0.08 | 19/33 kV (560 A) | −20…+90 °C |
| 3 × 400 mm² + 48F FIMT | 0.05 | 19/33 kV (710 A) | −20…+90 °C |
| 3 × 630 mm² + 96F FIMT | 0.03 | 19/33 kV (890 A) | −20…+90 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance, continuity & dimensional verification (API Spec 17E / ISO 13628-5 / IEC 60502-2 Subsea Boosting) | DC resistance at 20 °C / optical attenuation and outer diameter within API Spec 17E / ISO 13628-5 / IEC 60502-2 Subsea Boosting tolerances | Every manufactured drum length |
| High-voltage dielectric & insulation resistance test (API Spec 17E / ISO 13628-5 / IEC 60502-2 Subsea Boosting) | Zero dielectric breakdown and verified insulation resistance for 19/33 kV rating | Every manufactured drum length |
| Sample tests | ||
| Hydrostatic pressure, water-blocking & mechanical endurance qualification (API Spec 17E / ISO 13628-5 / IEC 60502-2 Subsea Boosting) | Verified submersion integrity, tensile load and thermal stability across −20…+90 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.