Immersion & wet locations
Hydrolysis-resistant ether-grade PUR/TPU jackets, water-blocked cores and optional atmospheric vent tubes support permanent immersion.
Product
SC-6122400 Digital Water Quality Sensor Cable featuring stranded copper twisted pairs (2×2) and subsea / marine outer protective sheath (EN 50288 / ISO 15839, 300 V, -40 to +80 °C, min. bend radius 6 × OD).
Typical values for this cable type, based on EN 50288 & ISO 15839 SC-6122400 Digital Water Quality Sensor Cable Standard — confirmed in the datasheet and quotation for your order.
Application fit
SC-6122400 Digital Water Quality Sensor Cable featuring stranded copper twisted pairs (2×2) and subsea / marine outer protective sheath (EN 50288 / ISO 15839, 300 V, -40 to +80 °C, min. bend radius 6 × OD).
Hydrolysis-resistant ether-grade PUR/TPU jackets, water-blocked cores and optional atmospheric vent tubes support permanent immersion.
Integrated aramid yarns or galvanized steel wire armour allow direct vertical probe suspension in sea cages, wells and stilling tubes.
Foil plus tinned copper braid screening protects low-level mV, 4–20 mA, SDI-12, RS-485 and optical DO signals from pump VFD noise.
Resists bio-fouling cleaning agents, saline splash, sunlight and −30/−40 °C winter freeze around open aquaculture tanks.
Submersible water-quality probe cables are designed for static/suspended immersion rather than high-speed machine drag chains.
Use CF211.PUR Encoder Chain CableConstruction
Shown: SC-6122400 Digital Water Sensor (EN 50288 & ISO 15839 SC-6122400 Digital Water Quality Sensor Cable Standard) featuring stranded copper twisted pairs (2×2), copper wire braid emc screen and subsea / marine outer protective sheath (3-layer construction).

| # | Layer | Material & reference |
|---|---|---|
| 1 | Stranded Copper Twisted Pairs (2×2) | Twisted pairs with High-stifiness polypropylene (PP) core insulation |
| 2 | Copper Wire Braid EMC Screen | High-coverage braided copper shield for EMI/VFD protection |
| 3 | Subsea / Marine Outer Protective Sheath | Black hydrolysis- & abrasion-resistant marine Polyurethane (PUR) outer sheath |
Built to EN 50288 & ISO 15839 SC-6122400 Digital Water Quality Sensor Cable Standard with stranded copper twisted pairs (2×2) and subsea / marine outer protective sheath
Available on continuous export winch drums or factory-terminated with subsea wet-mate / mechanical sockets
Supplied with EN 10204 3.1 routine dielectric, conductor/optical continuity & hydrostatic qualification report
Technical data
Sizes
Manufactured to EN 50288 & ISO 15839 SC-6122400 Digital Water Quality Sensor Cable Standard for subsea robotics, ROV umbilicals, marine aquaculture and offshore sensor applications.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Max. pulling kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| SC-6122400 Digital Water Sensor Construction Schedule (−40…+80 °C) | |||||||
| SC-6122400 Digital Water Sensor 1×2×22AWG RS-485 | 1 × 2 × 0.34 mm² (22 AWG) + Power Pair | Stranded SnCu + Foam PE + Foil/Braid | 8.2 | 92 | 2.0 | 50 | |
| SC-6122400 Digital Water Sensor 4×2×24AWG Cat5e | 4 × 2 × 24 AWG Subsea Gigabit Ethernet | Stranded SnCu + High-Pressure PE + SF/UTP | 9.6 | 125 | 3.5 | 60 | |
| SC-6122400 Digital Water Sensor 4×2×23AWG Cat6+2 | 4 × 2 × 23 AWG Cat6 + 2 × 1.5 mm² Power | Stranded SnCu + 600-Bar Matrix + PUR | 12.8 | 215 | 6.8 | 78 | |
| Configuration | Max. DC R₂₀ Ω/km | Rating / Impedance / Load | Operating temp. |
|---|---|---|---|
| 1 × 2 × 0.34 mm² (22 AWG) + Power Pair | 55.00 | 300 V (120 Ω RS-485) | −40…+80 °C |
| 4 × 2 × 24 AWG Subsea Gigabit Ethernet | 84.00 | 300 V (100 Ω 1000BASE-T) | −40…+80 °C |
| 4 × 2 × 23 AWG Cat6 + 2 × 1.5 mm² Power | 72.00 | 300 V (100 Ω Cat6 6000m) | −40…+80 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor DC resistance / OTDR optical & dimensional check (EN 50288 & ISO 15839 SC-6122400 Digital Water Quality Sensor Cable Standard) | DC resistance at 20 °C, optical attenuation and wall thickness within EN 50288 & ISO 15839 SC-6122400 Digital Water Quality Sensor Cable Standard limits | Every manufactured drum length |
| AC high-voltage dielectric & insulation resistance test (EN 50288 & ISO 15839 SC-6122400 Digital Water Quality Sensor Cable Standard) | Zero dielectric breakdown and verified wet insulation resistance for 300 V rating | Every manufactured drum length |
| Sample tests | ||
| Hydrostatic pressure, tensile load & seawater immersion qualification (EN 50288 & ISO 15839 SC-6122400 Digital Water Quality Sensor Cable Standard) | Verified hydrostatic pressure integrity, breaking load and flex endurance across −40…+80 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.