Mine roadway & tunnel wall hangers
Engineered for underground mining shafts, galleries and tunnel infrastructure per PN-EN 60228 / IEC 60332-1-2 / GIG Barbara.
Product
Engineered for underground mining, open-cast excavation, shaft infrastructure and heavy industrial service per PN-EN 60228 / IEC 60332-1-2 / GIG Barbara across -25 to +70 °C.
Typical values for this cable type, based on PN-EN 60228 / IEC 60332-1-2 / GIG Barbara — confirmed in the datasheet and quotation for your order.
Application fit
Engineered for underground mining, open-cast excavation, shaft infrastructure and heavy industrial service per PN-EN 60228 / IEC 60332-1-2 / GIG Barbara across -25 to +70 °C.
Engineered for underground mining shafts, galleries and tunnel infrastructure per PN-EN 60228 / IEC 60332-1-2 / GIG Barbara.
Suitable for vertical shaft cleats, gallery messenger hooks and tray routing within 8 × OD.
Supports inclined roadway and vertical mine shaft suspension within rated kN load across -25 to +70 °C.
Not optimized for high-speed overhead crane C-track festoon loops; select a dedicated festoon cable.
NGFLGÖU Flat Rubber Festoon CableConstruction
Shown: PSY 2x1.5 (PN-EN 60228 / IEC 60332-1-2 / GIG Barbara) featuring parallel conductors (2×1.5 mm²), parallel red & green pvc insulation (y) and flat high-visibility yellow sheath (y) (3-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | Parallel Conductors (2×1.5 mm²) | PN-EN 60228 Class 5 flexible bare annealed copper (≤26.6 Ω/km loop) |
| 2 | Parallel Red & Green PVC Insulation (Y) | Color-coded Red and Green PVC cores laid parallel side-by-side |
| 3 | Flat High-Visibility Yellow Sheath (Y) | 2.5×5.0 mm flat yellow mining flame-retardant PVC jacket (LOI ≥ 28%, 3 kV test) |
Built to PN-EN 60228 / IEC 60332-1-2 / GIG Barbara with parallel conductors (2×1.5 mm²) and flat high-visibility yellow sheath (y)
Available in custom shaft/roadway drum lengths or pre-terminated assemblies
Supplied with EN 10204 3.1 routine dielectric, resistance & flame test report
Technical data
Sizes
Manufactured to PN-EN 60228 / IEC 60332-1-2 / GIG Barbara for underground mining, open-cast excavation, shaft and heavy industrial systems.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Tensile rating kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| PSY 2x1.5 Construction Schedule (-25 to +70 °C) | |||||||
| PSY 2×1.0 mm² Auxiliary Firing Line | 2 × 1.0 mm² Flat Parallel | Class 5 bare Cu | 4.4 | 31 | 0.3 | 35 | |
| PSY 2×1.5 mm² Standard Shotfiring Line | 2 × 1.5 mm² Flat Parallel (2.5×5.0) | Class 5 bare Cu | 5.0 | 42 | 0.5 | 40 | |
| PSY 2×2.5 mm² Long-Gallery Firing Bus | 2 × 2.5 mm² Flat Parallel | Class 5 bare Cu | 6.2 | 66 | 0.8 | 50 | |
| Configuration | Max. DC R₂₀ / Atten. Ω/km or dB/km | Rating / Impedance | Operating temp. |
|---|---|---|---|
| 2 × 1.0 mm² Flat Parallel | 19.50 | ≤39.0 Ω/km loop (3 kV test) | -25 to +70 °C |
| 2 × 1.5 mm² Flat Parallel | 13.30 | ≤26.6 Ω/km loop (3 kV test) | -25 to +70 °C |
| 2 × 2.5 mm² Flat Parallel | 7.98 | ≤16.0 Ω/km loop (3 kV test) | -25 to +70 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance, continuity & dimensional verification (PN-EN 60228 / IEC 60332-1-2 / GIG Barbara) | DC resistance at 20 °C / optical attenuation and outer diameter within PN-EN 60228 / IEC 60332-1-2 / GIG Barbara tolerances | Every manufactured drum length |
| High-voltage dielectric & insulation resistance test (PN-EN 60228 / IEC 60332-1-2 / GIG Barbara) | Zero dielectric breakdown and verified insulation resistance over full production length | Every manufactured drum length |
| Sample tests | ||
| Flame propagation, mechanical crush & thermal ageing qualification (PN-EN 60228 / IEC 60332-1-2 / GIG Barbara) | Verified flame retardancy, mechanical integrity and thermal endurance across -25 to +70 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.