Mine roadway & tunnel wall hangers
Engineered for underground mining shafts, galleries and tunnel infrastructure per ZN-TF-017 / EMAG / EN 60794-1-2.
Product
Engineered for underground mining, open-cast excavation, shaft infrastructure and heavy industrial service per ZN-TF-017 / EMAG / EN 60794-1-2 across -40 to +80 °C.
Typical values for this cable type, based on ZN-TF-017 / EMAG / EN 60794-1-2 — confirmed in the datasheet and quotation for your order.
Application fit
Engineered for underground mining, open-cast excavation, shaft infrastructure and heavy industrial service per ZN-TF-017 / EMAG / EN 60794-1-2 across -40 to +80 °C.
Engineered for underground mining shafts, galleries and tunnel infrastructure per ZN-TF-017 / EMAG / EN 60794-1-2.
Suitable for vertical shaft cleats, gallery messenger hooks and tray routing within 10 × OD.
Supports inclined roadway and vertical mine shaft suspension within rated kN load across -40 to +80 °C.
Not optimized for high-speed overhead crane C-track festoon loops; select a dedicated festoon cable.
NGFLGÖU Flat Rubber Festoon CableConstruction
Shown: PSKD (ZN-TF-017 / EMAG / EN 60794-1-2) featuring central elastomeric buffer rod, 0.9 mm tight-buffered fibres (8j) and hffr-pur outer jacket (5-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | Central Elastomeric Buffer Rod | Flexible central element stabilizing core geometry under small-radius reeling |
| 2 | 0.9 mm Tight-Buffered Fibres (8J) | Color-coded 900 µm tight polyamide/elastomer buffered SM/MM fibres |
| 3 | Inner Aramid & Inner PUR Sheath | First aramid yarn layer + extruded inner polyurethane cushioning sheath |
| 4 | Outer Aramid Tensile Layer (2500 N) | Second concentric high-tenacity aramid layer for dynamic reeling load |
| 5 | HFFR-PUR Outer Jacket | Black halogen-free flame-retardant polyurethane jacket (1.4 mm wall) |
Built to ZN-TF-017 / EMAG / EN 60794-1-2 with central elastomeric buffer rod and hffr-pur outer jacket
Available in custom shaft/roadway drum lengths or pre-terminated assemblies
Supplied with EN 10204 3.1 routine dielectric, resistance & flame test report
Technical data
Sizes
Manufactured to ZN-TF-017 / EMAG / EN 60794-1-2 for underground mining, open-cast excavation, shaft and heavy industrial systems.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Tensile rating kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| PSKD Construction Schedule (-40 to +80 °C) | |||||||
| PSKD 4J (4×0.9 mm) HFFR-PUR | 4 × 0.9 mm Tight-Buffered FO | Double Aramid + Double PUR | 7.8 | 58 | 2.5 | 78 | |
| PSKD 8J (8×0.9 mm) HFFR-PUR | 8 × 0.9 mm Tight-Buffered FO | Double Aramid + Double PUR | 8.6 | 69 | 2.5 | 86 | |
| PSKD 12J (12×0.9 mm) HFFR-PUR | 12 × 0.9 mm Tight-Buffered FO | Double Aramid + Double PUR | 9.4 | 82 | 2.8 | 94 | |
| Configuration | Max. DC R₂₀ / Atten. Ω/km or dB/km | Rating / Impedance | Operating temp. |
|---|---|---|---|
| 4 × 0.9 mm Tight-Buffered FO | 0.40 | 2500 N tensile · 3000 N/100mm crush | -40 to +80 °C |
| 8 × 0.9 mm Tight-Buffered FO | 0.40 | 2500 N tensile · 3000 N/100mm crush | -40 to +80 °C |
| 12 × 0.9 mm Tight-Buffered FO | 0.40 | 2800 N tensile · 3000 N/100mm crush | -40 to +80 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance, continuity & dimensional verification (ZN-TF-017 / EMAG / EN 60794-1-2) | DC resistance at 20 °C / optical attenuation and outer diameter within ZN-TF-017 / EMAG / EN 60794-1-2 tolerances | Every manufactured drum length |
| High-voltage dielectric & insulation resistance test (ZN-TF-017 / EMAG / EN 60794-1-2) | Zero dielectric breakdown and verified insulation resistance over full production length | Every manufactured drum length |
| Sample tests | ||
| Flame propagation, mechanical crush & thermal ageing qualification (ZN-TF-017 / EMAG / EN 60794-1-2) | Verified flame retardancy, mechanical integrity and thermal endurance across -40 to +80 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.