Switchgear & control cabinet wiring
7-wire AWG 22/7 stranded conductors flex across hinged cabinet doors and vibrating machine frames.
Product
PROFINET Type B is the flexible 100 Ω Cat5e Industrial Ethernet cable per PNO Guideline 2.142 and IEC 61156-6 built with 7-strand tinned copper conductors (2×2×AWG22/7, Ø 0.75 mm) in a Star-Quad FastConnect core, SF/UTP foil-plus-braid shielding, and a RAL
Typical values for this cable type, based on IEC 61156-6 / PNO Guideline 2.142 (Type B) — confirmed in the datasheet and quotation for your order.
Application fit
Designed for machine tools, vibrating skids, swinging cabinet doors, and flexible patch/interconnect runs where solid Type A conductors would fatigue.
7-wire AWG 22/7 stranded conductors flex across hinged cabinet doors and vibrating machine frames.
Routes easily through tight machine-tool bends and multi-axis assembly cells.
Suitable for operator HMI arms and movable diagnostic drop leads.
For high-cycle continuous drag chains (>100,000 cycles) specify PROFINET Type C (AWG 22/19).
PROFINET Type CConstruction
Four AWG 22/7 (7×0.25 mm, Ø 0.75 mm) stranded tinned copper conductors with PE insulation in a Star-Quad lay (White, Yellow, Blue
| # | Layer | Material & reference |
|---|---|---|
| 1 | 7-wire tinned copper conductor | AWG 22/7 (7×0.25 mm, 0.34 mm², Ø 0.75 mm) stranded tinned copper per IEC 61156-6IEC 61156-6 / PNO Type B |
| 2 | Core insulation (PE / O2YS) | Low-capacitance polyethylene / foam-skin PE insulation (Ø 1.55 mm)PNO 2.142 |
| 3 | Star-Quad core lay-up | 4 cores twisted in Star-Quad (White, Yellow, Blue, Orange) around central fillerPNO 2.142 |
| 4 | FastConnect inner bedding | Thermoplastic inner jacket maintaining circular 6.5 mm FastConnect stripping profilePNO FastConnect spec |
| 5 | Static screen (Al/PET) | Aluminium-laminated polyester tape (100 % coverage)IEC 61156-6 SF/UTP |
| 6 | EMC copper braid | Tinned copper wire braid, optical coverage ≥ 85 %IEC 61156-6 SF/UTP |
| 7 | Outer sheath (RAL 6018 green) | Flexible oil-resistant PVC, halogen-free PUR (TMPU), or FRNC/LSZH compoundPNO 2.142 Type B |
Flexible RAL 6018 green PVC FastConnect cable for vibrating machinery and panel wiring.
Halogen-free PUR (UL Style 21198/20963) or shipboard/railway FRNC-LSZH flexible cable.
Technical data
Sizes
Nominal dimensions, copper weights, impedance and transmission parameters for PROFINET Type B per IEC 61156-6 / PNO Guideline 2.142 (Type B).
| Order designation | Configuration | Conductor size | Outer Ø ≈ mm | Copper kg/km | Weight ≈ kg/km | Min. bend R fixed mm | Enquiry |
|---|---|---|---|---|---|---|---|
| Standard PROFINET Type B configurations | |||||||
| PROFINET Type B FC PVC 2×2×AWG22/7 | 2×2×AWG22/7 (PVC Flex) | AWG 22/7 (0.34 mm²) | 6.5 | 33 | 63 | 32 | |
| PROFINET Type B FC PUR 2×2×AWG22/7 | 2×2×AWG22/7 (PUR Flex) | AWG 22/7 (0.34 mm²) | 6.5 | 33 | 61 | 32 | |
| PROFINET Type B FC FRNC/LSZH 2×2×AWG22/7 | 2×2×AWG22/7 (FRNC/LSZH) | AWG 22/7 (0.34 mm²) | 6.5 | 33 | 65 | 32 | |
| PROFINET Type B Marine SHF1 2×2×AWG22/7 | 2×2×AWG22/7 (Marine SHF1) | AWG 22/7 (0.34 mm²) | 6.6 | 34 | 66 | 33 | |
| Configuration | Impedance Z0 | Max. DC R @ 20 °C Ω/km | Mutual C pF/m ≈ | VoP % | Attenuation @ 20 °C dB/100m | Dielectric test V |
|---|---|---|---|---|---|---|
| 2×2×AWG22/7 (PVC Flex) | 100 Ω | 120.0 | 50.0 | 65 | 2.5 @ 1 · 6.8 @ 10 · 21.8 @ 100 MHz | 2,000 |
| 2×2×AWG22/7 (PUR Flex) | 100 Ω | 120.0 | 50.0 | 65 | 2.5 @ 1 · 6.8 @ 10 · 21.8 @ 100 MHz | 2,000 |
| 2×2×AWG22/7 (FRNC/LSZH) | 100 Ω | 120.0 | 50.0 | 65 | 2.5 @ 1 · 6.8 @ 10 · 21.8 @ 100 MHz | 2,000 |
| 2×2×AWG22/7 (Marine SHF1) | 100 Ω | 120.0 | 50.0 | 65 | 2.5 @ 1 · 6.8 @ 10 · 21.8 @ 100 MHz | 2,000 |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| 1–100 MHz network analyzer sweep | Z0 = 100 ± 15 Ω, NEXT & return loss per IEC 61156-6 | 100 % of reels |
| DC loop resistance & 2 kV spark test | ≤ 120 Ω/km; 2.0 kV DC dielectric test | 100 % of reels |
| Sample tests | ||
| Vibration & bending fatigue test | PNO 2.142 Type B conductor integrity | Per production batch |
| Flame & oil resistance | IEC 60332-1-2 & EN 60811-404 | Type approval |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.