Fixed installation
IEC 60332-3-22 Cat. A bunched flame-retardant and IEC 60754/61034 low-smoke zero-halogen qualified for enclosed vessel spaces.
Product
M2XH & (L)M2XH / (L)M2XH-J 0.6/1 kV XLPE-Insulated Unarmoured Lightweight SHF1 Halogen-Free Shipboard Power & Lighting Cable (IEC 60092-353 / DIN 89160, 0.6/1 kV, -40 to +90 °C, min. bend radius 6 × OD).
Typical values for this cable type, based on IEC 60092-353 & DIN 89160 / IEC 60092-360 SHF1 — confirmed in the datasheet and quotation for your order.
Application fit
M2XH & (L)M2XH / (L)M2XH-J 0.6/1 kV XLPE-Insulated Unarmoured Lightweight SHF1 Halogen-Free Shipboard Power & Lighting Cable (IEC 60092-353 / DIN 89160, 0.6/1 kV, -40 to +90 °C, min. bend radius 6 × OD).
IEC 60332-3-22 Cat. A bunched flame-retardant and IEC 60754/61034 low-smoke zero-halogen qualified for enclosed vessel spaces.
SHF1 and oil-resistant SHF2 outer sheaths withstand engine-room bilge oils, salt fog and marine vibration.
Lightweight unarmoured and braided executions route easily through tight deckhead trays and accommodation modules.
90 °C XLPE/HF-EPR insulation provides high current-carrying capacity in high-ambient marine machinery spaces.
Fixed shipboard LSZH installation cable is not intended for continuous reciprocating drag chains.
Use Drag-Chain Control CableConstruction
Shown: M2XH & (L)M2XH-J 0.6/1 KV (IEC 60092-353 & DIN 89160 / IEC 60092-360 SHF1) featuring stranded copper conductors (4g16 mm²), xlpe core insulation (hd 308 s2) and shf1 lightweight outer sheath (4-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | Stranded Copper Conductors (4G16 mm²) | IEC 60228 Class 2 plain annealed stranded copper conductors |
| 2 | XLPE Core Insulation (HD 308 S2) | Cross-linked polyethylene coded Brown, Black, Grey and Green/Yellow |
| 3 | Halogen-Free Binder & Filler | Flame-retardant non-hygroscopic core filler and wrapping tape |
| 4 | SHF1 Lightweight Outer Sheath | Grey low-smoke zero-halogen polyolefin outer jacket (DIN 89160) |
Built to IEC 60092-353 & DIN 89160 / IEC 60092-360 SHF1 with stranded copper conductors (4g16 mm²) and shf1 lightweight outer sheath
Available in custom continuous shipboard/offshore drum lengths or with marine EMC cable glands
Supplied with EN 10204 3.1 routine dielectric, conductor resistance & flame/fire test report
Technical data
Sizes
Manufactured to IEC 60092-353 & DIN 89160 / IEC 60092-360 SHF1 for shipboard, offshore platform, drilling rig and marine applications.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Tensile rating kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| M2XH & (L)M2XH-J 0.6/1 KV Construction Schedule (−40…+90 °C) | |||||||
| M2XH 3×16+1G16 mm² | 3 × 16 + 1G16 mm² (4G16) | IEC 60228 Class 2/5 Cu/SnCu | 22.4 | 920 | 3.8 | 135 | |
| M2XH 3×35+1G16 mm² | 3 × 35 + 1G16 mm² (4G35) | IEC 60228 Class 2/5 Cu/SnCu | 28.8 | 1,690 | 7.4 | 175 | |
| M2XH 3×70+1G35 mm² | 3 × 70 + 1G35 mm² (4G70) | IEC 60228 Class 2/5 Cu/SnCu | 38.2 | 3,260 | 14.8 | 230 | |
| Configuration | Max. DC R₂₀ / Atten. Ω/km or dB/km | Rating / Impedance | Operating temp. |
|---|---|---|---|
| 3 × 16 + 1G16 mm² (4G16) | 1.15 | 0.6/1 kV (98 A) | −40…+90 °C |
| 3 × 35 + 1G16 mm² (4G35) | 0.52 | 0.6/1 kV (158 A) | −40…+90 °C |
| 3 × 70 + 1G35 mm² (4G70) | 0.27 | 0.6/1 kV (245 A) | −40…+90 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance, continuity & dimensional verification (IEC 60092-353 & DIN 89160 / IEC 60092-360 SHF1) | DC resistance at 20 °C / optical attenuation and outer diameter within IEC 60092-353 & DIN 89160 / IEC 60092-360 SHF1 tolerances | Every manufactured drum length |
| High-voltage dielectric & insulation resistance test (IEC 60092-353 & DIN 89160 / IEC 60092-360 SHF1) | Zero dielectric breakdown and verified insulation resistance for 0.6/1 kV rating | Every manufactured drum length |
| Sample tests | ||
| Flame, fire integrity, oil/mud & mechanical qualification (IEC 60092-353 & DIN 89160 / IEC 60092-360 SHF1) | Verified flame/fire performance, fluid resistance and thermal stability across −40…+90 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.