halogen-free shipboard cableIEC 60092-353 / DIN 891580.6/1 kV (-40 to +90 °C)SHF1 Halogen-Free Outer Sheath

M2XCH & (L)M2XCH 0.6/1 kV IEC 60092-353 / DIN 89158 Braided Halogen-Free Shipboard CableIEC 60092-353 / DIN 89158 — 0.6/1 kV — -40 to +90 °C Marine & Offshore Cable

M2XCH & (L)M2XCH 0.6/1 kV XLPE-Insulated Copper-Wire-Braid Screened SHF1 Halogen-Free Flame-Retardant Shipboard Power & Control Cable (IEC 60092-353 / DIN 89158, 0.6/1 kV, -40 to +90 °C, min. bend radius 6 × OD).

Flame-retardant
EMC screen
Oil-resistant
Approved
Order designation
M2XCH 3×16+1G16 mm²
Outer Ø ≈
22.4 mm
Net weight ≈
920 kg/km
Tensile rating ≈
3.8 kN
Core / stranding
IEC 60228 Class 2/5 Cu/SnCu
All sizes (3)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
0.6/1 kV
Tested per IEC 60092-353 / DIN 89158
Operating temp.
−40…+90 °C
Continuous shipboard & offshore service
Min. bend radius
6 × OD
Marine tray, bulkhead & deck routing
Core / conductor
Stranded Bare Co
IEC 60228 Class 2 / Class 5 plain anneal
Outer protection
SHF1 Halogen-Fre
Black low-smoke zero-halogen polyolefin
Standard
IEC 60092-353 /
IEC 60092-353 & DIN 89158 / IEC 60092-36

Typical values for this cable type, based on IEC 60092-353 & DIN 89158 / IEC 60092-360 SHF1 — confirmed in the datasheet and quotation for your order.

Application fit

Is M2XCH & (L)M2XCH 0.6/1 KV right for your machine?

M2XCH & (L)M2XCH 0.6/1 kV XLPE-Insulated Copper-Wire-Braid Screened SHF1 Halogen-Free Flame-Retardant Shipboard Power & Control Cable (IEC 60092-353 / DIN 89158, 0.6/1 kV, -40 to +90 °C, min. bend radius 6 × OD).

Fixed installation

Suitable

IEC 60332-3-22 Cat. A bunched flame-retardant and IEC 60754/61034 low-smoke zero-halogen qualified for enclosed vessel spaces.

Offshore platform & shipboard deck trays

Suitable

SHF1 and oil-resistant SHF2 outer sheaths withstand engine-room bilge oils, salt fog and marine vibration.

Switchgear & control cabinet wiring

Suitable

Lightweight unarmoured and braided executions route easily through tight deckhead trays and accommodation modules.

Motor stator, traction & converter leads

Suitable

90 °C XLPE/HF-EPR insulation provides high current-carrying capacity in high-ambient marine machinery spaces.

Energy chain / drag chain

Not suitable

Fixed shipboard LSZH installation cable is not intended for continuous reciprocating drag chains.

Use Drag-Chain Control Cable
Typical machinesMarine & Offshore CablePassenger Vessels, Ferries & YachtsMerchant Marine Engine & Cargo SpacesOffshore Living Quarters & Utility ModulesShipyard Newbuild & Retrofit Electrical Outfitting

Construction

Layer by layer

Shown: M2XCH & (L)M2XCH 0.6/1 KV (IEC 60092-353 & DIN 89158 / IEC 60092-360 SHF1) featuring stranded bare copper conductors (3×35 mm²), hf90 xlpe core insulation and shf1 halogen-free outer sheath (5-layer construction).

12345
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1Stranded Bare Copper Conductors (3×35 mmIEC 60228 Class 2 / Class 5 plain annealed copper conductors
2HF90 XLPE Core Insulation90 °C cross-linked polyethylene insulation identified Brown, Black, Grey
3Halogen-Free Extruded Inner CoveringNon-hygroscopic flame-retardant halogen-free bedding compound
4Copper Wire Braid Screen (C)High-coverage bare copper wire braid for EMC screening and protection
5SHF1 Halogen-Free Outer SheathBlack low-smoke zero-halogen polyolefin jacket (IEC 60092-360 SHF1)

M2XCH & (L)M2XCH 0.6/1 KV — Standard Shipboard & Offshore Execution

Built to IEC 60092-353 & DIN 89158 / IEC 60092-360 SHF1 with stranded bare copper conductors (3×35 mm²) and shf1 halogen-free outer sheath

M2XCH & (L)M2XCH 0.6/1 KV — Custom Drum Length & Gland Kit

Available in custom continuous shipboard/offshore drum lengths or with marine EMC cable glands

M2XCH & (L)M2XCH 0.6/1 KV — Class & Routine Test Certified

Supplied with EN 10204 3.1 routine dielectric, conductor resistance & flame/fire test report

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on IEC 60092-353 & DIN 89158 / IEC 60092-360 SHF1. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage / transmission duty
0.6/1 kV (IEC 60092-353 & DIN 89158 / IEC 60092-360 SHF1)
Core / conductor construction
Stranded Bare Copper Conductors (3×35 mm²) — IEC 60228 Class 2 / Class 5 plain annealed copper conductors
Primary dielectric / buffering
HF90 XLPE Core Insulation — 90 °C cross-linked polyethylene insulation identified Brown, Black, Grey

Thermal

Continuous operating temperature
−40…+90 °C (shipboard & offshore duty)
Short-circuit / peak thermal rating
Verified thermal stability per IEC 60092-353 & DIN 89158 / IEC 60092-360 SHF1
Storage & transport temperature
−40…+80 °C on export wooden/steel drum

Mechanical

Outer protection / armouring
SHF1 Halogen-Free Outer Sheath — Black low-smoke zero-halogen polyolefin jacket (IEC 60092-360 SHF1)
Minimum bending radius
6 × OD
Armour, screen & mechanical duty
Copper Wire Braid Screen (C) — High-coverage bare copper wire braid for EMC screening and protection

Resistance

Flame, fire & smoke performance
Qualified for marine flame-retardance and low-smoke zero-halogen / fire safety per IEC 60092-353 & DIN 89158 / IEC 60092-360 SHF1
Oil, drilling mud & seawater resistance
Resistant to marine fuel/lube oils, salt mist and offshore fluids per IEC 60092-353 & DIN 89158 / IEC 60092-360 SHF1
RoHS & REACH compliance
RoHS 2 (2011/65/EU + 2015/863) & REACH SVHC compliant

Reference standards

Governing standard
IEC 60092-353 & DIN 89158 / IEC 60092-360 SHF1
Environmental & test standards
IEC 60228 / IEC 60332-3-22 / IEC 60754 / IEC 61034 / EN 10204
Quality management & inspection
ISO 9001:2015 & EN 10204 3.1 factory routine inspection

Identification

Model designation
M2XCH & (L)M2XCH 0.6/1 KV
Sheath colour & metre marking
Continuous metre-marked black outer finish (SHF1 Halogen-Fre)
Customs tariff (HS)
8544.49 / 8544.60 / 8544.70

Sizes

3 standard M2XCH & (L)M2XCH 0.6/1 KV shipboard & offshore configurations

Manufactured to IEC 60092-353 & DIN 89158 / IEC 60092-360 SHF1 for shipboard, offshore platform, drilling rig and marine applications.

Dimensions, tensile load & weights
Order designationConfigurationCore / strandingOuter Ø ≈
mm
Net weight ≈
kg/km
Tensile rating
kN ≈
Min. bend R
mm
Enquiry
M2XCH & (L)M2XCH 0.6/1 KV Construction Schedule (−40…+90 °C)
M2XCH 3×16+1G16 mm²3 × 16 + 1G16 mm² (4G16)IEC 60228 Class 2/5 Cu/SnCu22.49203.8135
M2XCH 3×35+1G16 mm²3 × 35 + 1G16 mm² (4G35)IEC 60228 Class 2/5 Cu/SnCu28.81,6907.4175
M2XCH 3×70+1G35 mm²3 × 70 + 1G35 mm² (4G70)IEC 60228 Class 2/5 Cu/SnCu38.23,26014.8230
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Custom core cross-sections, pair/fibre counts, armour grades and factory drum lengths available per IEC 60092-353 & DIN 89158 / IEC 60092-360 SHF1.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
Conductor resistance, continuity & dimensional verification (IEC 60092-353 & DIN 89158 / IEC 60092-360 SHF1)DC resistance at 20 °C / optical attenuation and outer diameter within IEC 60092-353 & DIN 89158 / IEC 60092-360 SHF1 tolerancesEvery manufactured drum length
High-voltage dielectric & insulation resistance test (IEC 60092-353 & DIN 89158 / IEC 60092-360 SHF1)Zero dielectric breakdown and verified insulation resistance for 0.6/1 kV ratingEvery manufactured drum length
Sample tests
Flame, fire integrity, oil/mud & mechanical qualification (IEC 60092-353 & DIN 89158 / IEC 60092-360 SHF1)Verified flame/fire performance, fluid resistance and thermal stability across −40…+90 °CType qualification & periodic lot audit

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

IEC 60092-353 / DIN 89158 CompliantEN 10204 3.1 Factory Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

TEBAOFLEX M2XCH & (L)M2XCH 0.6/1 KV IEC 60092-353 / DIN 89158 0.6/1 kV CE
Delivery form
Heavy-duty export fumigated wooden drums or steel marine reels
Standard lengths
500 m, 1,000 m or custom continuous shipboard/offshore lengths
MOQ
100 m (standard configurations) · 500 m (custom builds)
Lead time
2–5 weeks ex-works
Incoterms
EXW, FCA, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-10-25
Updated
2026-10-25

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What governing standard and construction define M2XCH & (L)M2XCH 0.6/1 KV (M2XCH & (L)M2XCH 0.6/1 kV IEC 60092-353 / DIN 89158 Braided Halogen-Free Shipboard Cable)?
M2XCH & (L)M2XCH 0.6/1 KV (M2XCH & (L)M2XCH 0.6/1 kV IEC 60092-353 / DIN 89158 Braided Halogen-Free Shipboard Cable) is manufactured in accordance with IEC 60092-353 & DIN 89158 / IEC 60092-360 SHF1 for 0.6/1 kV service over -40 to +90 °C. Its 5-layer construction comprises stranded bare copper conductors (3×35 mm²), hf90 xlpe core insulation and shf1 halogen-free outer sheath.
What is the minimum bending radius and operating temperature range for M2XCH & (L)M2XCH 0.6/1 KV?
The minimum bending radius for M2XCH & (L)M2XCH 0.6/1 KV is 6 × OD across its continuous operating temperature range of -40 to +90 °C, ensuring mechanical and dielectric reliability in shipboard and offshore service.
How are the concentric layers of M2XCH & (L)M2XCH 0.6/1 KV arranged from inside to outside?
From inside to outside, the construction sequence is: (01) Stranded Bare Copper Conductors (3×35 mm²) — IEC 60228 Class 2 / Class 5 plain annealed copper conductors; (02) HF90 XLPE Core Insulation — 90 °C cross-linked polyethylene insulation identified Brown, Black, Grey; (03) Halogen-Free Extruded Inner Covering — Non-hygroscopic flame-retardant halogen-free bedding compound; (04) Copper Wire Braid Screen (C) — High-coverage bare copper wire braid for EMC screening and protection; (05) SHF1 Halogen-Free Outer Sheath — Black low-smoke zero-halogen polyolefin jacket (IEC 60092-360 SHF1).
What factory test certificates are supplied with M2XCH & (L)M2XCH 0.6/1 KV?
Every production drum of M2XCH & (L)M2XCH 0.6/1 KV undergoes routine conductor resistance/continuity, high-voltage dielectric and dimensional testing per IEC 60092-353 & DIN 89158 / IEC 60092-360 SHF1, and is delivered with an EN 10204 3.1 factory test certificate.

Request a quote

Get an engineering quote for M2XCH & (L)M2XCH 0.6/1 KV

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

M2XCH & (L)M2XCH 0.6/1 kV IEC 60092-353 / DIN 89158 Braided Halogen-Free Shipboard Cable

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote