Free-hanging vertical run
Class 5 flexible copper cores and cross-linked EPR / silicone / PCP rubber jackets survive >10,000–18,000 yaw drip-loop torsion cycles.
Product
IEC 0.6/1 kV & UL 2277 Type WTTC 1,000 V Copper-Braid Shielded Wind Turbine Torsion Cable (UL 2277 WTTC / IEC 60502-1) engineered for 0.6/1 kV / 1,000 V wind turbine service across -40 to +90 °C (min. bend radius 6 × OD).
Typical values for this cable type, based on UL Subject 2277 Type WTTC 1,000 V & IEC 60502-1 0.6/1 kV Shielded Wind Specification — confirmed in the datasheet and quotation for your order.
Application fit
IEC 0.6/1 kV & UL 2277 Type WTTC 1,000 V Copper-Braid Shielded Wind Turbine Torsion Cable (UL 2277 WTTC / IEC 60502-1) engineered for 0.6/1 kV / 1,000 V wind turbine service across -40 to +90 °C (min. bend radius 6 × OD).
Class 5 flexible copper cores and cross-linked EPR / silicone / PCP rubber jackets survive >10,000–18,000 yaw drip-loop torsion cycles.
Routes continuously from nacelle generators and yaw/pitch cabinets through the free-hanging drip loop into upper tower trays.
Polychloroprene (CR/PCP), CPE, silicone (FDGG) and PUR (FDGU) sheaths resist hydraulic oil, grease, ozone, salt spray and −40 to −55 °C co
Copper-braid screened variants (FDEFP, FDEHP, WINDLINK WTTC) contain PWM converter electromagnetic interference along the drip loop.
Wind turbine vertical torsion rubber cable is optimized for axial twist rather than high-speed trolley festoons.
Use (N)3GRDC5G-J/O Festoon CableConstruction
Shown: IEC 0.6/1 kV & UL WTTC 1000V Shielded (UL Subject 2277 Type WTTC 1,000 V & IEC 60502-1 0.6/1 kV Shielded Wind Specification) featuring iec 60228 class 5 flexible copper (4g10 mm²), epr dual-standard core insulation and cold & oil-resistant elastomer jacket (-40 °c) (4-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | IEC 60228 Class 5 Flexible Copper (4G10 | Four flexible plain copper cores (3 phases + 1 green/yellow PE) |
| 2 | EPR Dual-Standard Core Insulation | Ethylene-propylene rubber rated 0.6/1 kV IEC and 1,000 V UL WTTC |
| 3 | Copper Wire Braid EMC Shield | Braided copper wire screen suppressing auxiliary VFD interference |
| 4 | Cold & Oil-Resistant Elastomer Jacket (- | Black flame-retardant thermoset elastomer outer sheath |
Built to UL Subject 2277 Type WTTC 1,000 V & IEC 60502-1 0.6/1 kV Shielded Wind Specification with iec 60228 class 5 flexible copper (4g10 mm²) and cold & oil-resistant elastomer jacket (-40 °c)
Available on bulk export reels or pre-cut to turbine tower section and nacelle drip-loop lengths
Supplied with EN 10204 3.1 routine dielectric, conductor DC resistance & cold-torsion qualification report
Technical data
Sizes
Manufactured to UL Subject 2277 Type WTTC 1,000 V & IEC 60502-1 0.6/1 kV Shielded Wind Specification for wind turbine yaw drip-loop, pitch control, tower power and converter applications.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Max. pulling kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| IEC 0.6/1 kV & UL WTTC 1000V Shielded Construction Schedule (−40…+90 °C) | |||||||
| IEC 0.6 4G16 / 3×16+3G2.5 | 4G16 mm² (or 3×6 AWG + 3G10 AWG) | IEC 60228 Class 5 / Class K Cu | 21.8 | 790 | 9.5 | 130 | |
| IEC 0.6 4G50 / 3×50+3G10 | 4G50 mm² (or 3×1 AWG + 3G6 AWG) | IEC 60228 Class 5 / Class K Cu | 31.4 | 2,140 | 22.5 | 190 | |
| IEC 0.6 3×150+3G25 VFD | 3×150 + 3G25 mm² (or 3×350 kcmil) | IEC 60228 Class 5 / Class K Cu | 47.2 | 5,480 | 58.0 | 285 | |
| Configuration | Max. DC R₂₀ Ω/km | Rating / Impedance | Operating temp. |
|---|---|---|---|
| 4G16 mm² (or 3×6 AWG + 3G10 AWG) | 1.15 | 0.6/1 kV / 1,000 V (98 A VFD) | −40…+90 °C |
| 4G50 mm² (or 3×1 AWG + 3G6 AWG) | 0.39 | 0.6/1 kV / 1,000 V (195 A VFD) | −40…+90 °C |
| 3×150 + 3G25 mm² (or 3×350 kcmil) | 0.13 | 0.6/1 kV / 1,000 V (395 A VFD) | −40…+90 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor DC resistance & dimensional verification (UL Subject 2277 Type WTTC 1,000 V & IEC 60502-1 0.6/1 kV Shielded Wind Specification) | DC resistance at 20 °C and insulation/sheath wall thickness within UL Subject 2277 Type WTTC 1,000 V & IEC 60502-1 0.6/1 kV Shielded Wind Specification limits | Every manufactured drum length |
| AC high-voltage dielectric & insulation resistance test (UL Subject 2277 Type WTTC 1,000 V & IEC 60502-1 0.6/1 kV Shielded Wind Specification) | Zero dielectric breakdown and verified insulation resistance for 0.6/1 kV / 1,000 V rating | Every manufactured drum length |
| Sample tests | ||
| Low-temperature drip-loop torsion, oil & flame qualification (UL Subject 2277 Type WTTC 1,000 V & IEC 60502-1 0.6/1 kV Shielded Wind Specification) | Verified cold torsion cycle endurance, oil resistance and flame retardancy across −40…+90 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.