Switchgear & control cabinet wiring
Engineered and verified for cabinet chassis service in accordance with UL AWM Style 20130 / CSA.
Product
1700-10 Twisted-Pair Flat Ribbon Cable (0.050" Pitch) (IDC 1700-10) engineered to UL AWM Style 20130 / CSA for 300 V service across -20 °C to +105 °C, featuring stranded tinned copper conductor and pvc core insulation with minimum bending radius 5 × OD.
Typical values for this cable type, based on UL AWM Style 20130 / CSA — confirmed in the datasheet and quotation for your order.
Application fit
1700-10 Twisted-Pair Flat Ribbon Cable (0.050" Pitch) (IDC 1700-10) engineered to UL AWM Style 20130 / CSA for 300 V service across -20 °C to +105 °C, featuring stranded tinned copper conductor and pvc core insulation with minimum bending radius 5 × OD.
Engineered and verified for cabinet chassis service in accordance with UL AWM Style 20130 / CSA.
Qualified for fixed installation on trays, racks, conduits or supports per UL AWM Style 20130 / CSA.
Use mechanical conduit or armoured protection where exposed to rock fall or crushing loads.
Not designed for high-speed monospiral crane reeling; select a dedicated reeling cable.
NSHTOU Reeling CableConstruction
Shown: IDC 1700-10 (UL AWM Style 20130 / CSA) with stranded tinned copper conductor, pvc core insulation and pvc core insulation (2-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | Stranded tinned copper conductor | High-conductivity tinned copper conductor per UL AWM Style 20130 / CSAUL AWM Style 20130 / CSA |
| 2 | PVC core insulation | Extruded PVC dielectric (individual core / group layer)UL AWM Style 20130 / CSA |
Built to UL AWM Style 20130 / CSA with stranded tinned copper conductor and pvc core insulation
Full range of metric mm² and AWG/kcmil conductor sizes per UL AWM Style 20130 / CSA
Supplied with EN 10204 3.1 routine dielectric & conductor resistance test certificate
Technical data
Sizes
Manufactured to UL AWM Style 20130 / CSA in single-pair, multi-pair and multi-unit constructions.
| Order designation | Configuration | Outer Ø ≈ mm | Weight ≈ kg/km | Min. bend R fixed mm | Enquiry |
|---|---|---|---|---|---|
| IDC 1700-10 Standard Construction Schedule (300 V · −20…+105 °C) | |||||
| IDC 1700-10 1×2×0.5 | 1×2×0.5 mm² | 6.4 | 58 | 52 | |
| IDC 1700-10 2×2×0.5 | 2×2×0.5 mm² | 9.2 | 112 | 74 | |
| IDC 1700-10 4×2×0.5 | 4×2×0.5 mm² | 11.4 | 176 | 92 | |
| IDC 1700-10 8×2×0.5 | 8×2×0.5 mm² | 14.8 | 295 | 118 | |
| IDC 1700-10 12×2×0.5 | 12×2×0.5 mm² | 17.6 | 420 | 141 | |
| IDC 1700-10 1×2×1.0 | 1×2×1.0 mm² | 7.6 | 86 | 61 | |
| IDC 1700-10 2×2×1.0 | 2×2×1.0 mm² | 11.0 | 168 | 88 | |
| IDC 1700-10 4×2×1.0 | 4×2×1.0 mm² | 13.5 | 264 | 108 | |
| IDC 1700-10 8×2×1.0 | 8×2×1.0 mm² | 17.9 | 465 | 143 | |
| IDC 1700-10 1×2×1.5 | 1×2×1.5 mm² | 8.5 | 114 | 68 | |
| IDC 1700-10 4×2×1.5 | 4×2×1.5 mm² | 15.2 | 348 | 122 | |
| IDC 1700-10 12×2×1.5 | 12×2×1.5 mm² | 23.4 | 860 | 187 | |
| Conductor size | Max. DC R₂₀ Ω/km | Mutual cap. ≈ nF/km | Inductance ≈ mH/km |
|---|---|---|---|
| 0.50 mm² (7/0.30 mm · AWG 20) | 39.00 | 115 | 0.65 |
| 0.75 mm² (7/0.37 mm · AWG 18) | 26.00 | 120 | 0.62 |
| 1.00 mm² (7/0.43 mm · AWG 17) | 19.50 | 125 | 0.60 |
| 1.50 mm² (7/0.53 mm · AWG 16) | 13.30 | 135 | 0.58 |
| 2.50 mm² (7/0.67 mm · AWG 14) | 7.98 | 145 | 0.55 |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor DC resistance & dimensional verification (UL AWM Style 20130 / CSA) | DC resistance at 20 °C and geometry within UL AWM Style 20130 / CSA class limits | Every manufactured drum / spool |
| Routine dielectric / spark / structural integrity test (UL AWM Style 20130 / CSA) | Zero breakdown or structural defect over full production length | Every manufactured drum / spool |
| Sample tests | ||
| Thermal aging, mechanical & material qualification (UL AWM Style 20130 / CSA) | Full compliance with UL AWM Style 20130 / CSA across −20…+105 °C | Type qualification & periodic sample audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.