Contact

1700-10 Twisted-Pair Flat Ribbon Cable (0.050" Pitch)UL AWM Style 20130 / CSA · 300 V · -20 °C to +105 °C industrial IDC 1700-10 construction

1700-10 Twisted-Pair Flat Ribbon Cable (0.050" Pitch) (IDC 1700-10) engineered to UL AWM Style 20130 / CSA for 300 V service across -20 °C to +105 °C, featuring stranded tinned copper conductor and pvc core insulation with minimum bending radius 5 × OD.

Approved
Flame-retardant
Oil-resistant
Order designation
IDC 1700-10 4×2×1.0
Outer Ø ≈
13.5 mm
Total weight ≈
264 kg/km
Min. bend R (fixed)
108 mm
Configuration
4×2×1.0 mm²
All sizes (12)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
300 V
Per UL AWM Style 20130 / CSA
Operating temp.
−20…+105 °C
Continuous thermal rating
Min. bend radius
5 × OD
Installed / fixed routing
Conductor
tinned copper
High-conductivity tinned copper
Outer layer
PVC core insulat
Extruded PVC dielectric
Standard
UL AWM Style
UL AWM Style 20130 / CSA

Typical values for this cable type, based on UL AWM Style 20130 / CSA — confirmed in the datasheet and quotation for your order.

Application fit

Is IDC 1700-10 right for your machine?

1700-10 Twisted-Pair Flat Ribbon Cable (0.050" Pitch) (IDC 1700-10) engineered to UL AWM Style 20130 / CSA for 300 V service across -20 °C to +105 °C, featuring stranded tinned copper conductor and pvc core insulation with minimum bending radius 5 × OD.

Switchgear & control cabinet wiring

Suitable

Engineered and verified for cabinet chassis service in accordance with UL AWM Style 20130 / CSA.

Fixed installation

Suitable

Qualified for fixed installation on trays, racks, conduits or supports per UL AWM Style 20130 / CSA.

TBM gantry & advancing tunnel reel

With conditions

Use mechanical conduit or armoured protection where exposed to rock fall or crushing loads.

Motorised monospiral reel

Not suitable

Not designed for high-speed monospiral crane reeling; select a dedicated reeling cable.

NSHTOU Reeling Cable
Typical machinesAerospace & AvionicsAutomated Assembly & Packaging LinesCNC Machine Tools & RoboticsPLC/DCS Control & Marshalling CabinetsIndustrial Drives & Motor ManufacturingAvionics Backplanes & Rack Interconnects

Construction

Layer by layer

Shown: IDC 1700-10 (UL AWM Style 20130 / CSA) with stranded tinned copper conductor, pvc core insulation and pvc core insulation (2-layer construction).

12
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1Stranded tinned copper conductorHigh-conductivity tinned copper conductor per UL AWM Style 20130 / CSAUL AWM Style 20130 / CSA
2PVC core insulationExtruded PVC dielectric (individual core / group layer)UL AWM Style 20130 / CSA

IDC 1700-10 — Standard Execution

Built to UL AWM Style 20130 / CSA with stranded tinned copper conductor and pvc core insulation

IDC 1700-10 — Custom Cross-Sections

Full range of metric mm² and AWG/kcmil conductor sizes per UL AWM Style 20130 / CSA

IDC 1700-10 — Export Drum Supply

Supplied with EN 10204 3.1 routine dielectric & conductor resistance test certificate

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on UL AWM Style 20130 / CSA. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage / duty
300 V (UL AWM Style 20130 / CSA)
Conductor construction
Stranded tinned copper conductor — High-conductivity tinned copper conductor per UL AWM Style 20130 / CSA
Primary insulation / dielectric
PVC core insulation — Extruded PVC dielectric (individual core / group layer)

Thermal

Continuous operating temperature
−20…+105 °C per UL AWM Style 20130 / CSA
Short-circuit / peak thermal limit
+160 °C to +250 °C (5 s adiabatic limit depending on dielectric class)
Minimum installation temperature
−5 °C (thermoplastic) / −25 °C (cross-linked or elastomer) / −40 °C (metallic)

Mechanical

Outer protection / covering
PVC core insulation — Extruded PVC dielectric (individual core / group layer)
Minimum bending radius
5 × OD (installed / static routing)
Layer count & geometry
2 concentric/structural layers verified by cross-section inspection

Resistance

Environmental & chemical durability
Engineered for industrial service in accordance with UL AWM Style 20130 / CSA
RoHS & REACH compliance
RoHS 2 (2011/65/EU + 2015/863) & REACH SVHC compliant

Reference standards

Governing product standard
UL AWM Style 20130 / CSA
Quality management & inspection
ISO 9001:2015 & EN 10204 3.1 factory routine inspection

Identification

Model designation
IDC 1700-10
Customs tariff (HS)
8544.49 / 8544.60 / 7614.10

Sizes

12 standard IDC 1700-10 cable configurations

Manufactured to UL AWM Style 20130 / CSA in single-pair, multi-pair and multi-unit constructions.

Dimensions, construction & weights
Order designationConfigurationOuter Ø ≈
mm
Weight ≈
kg/km
Min. bend R
fixed mm
Enquiry
IDC 1700-10 Standard Construction Schedule (300 V · −20…+105 °C)
IDC 1700-10 1×2×0.51×2×0.5 mm²6.45852
IDC 1700-10 2×2×0.52×2×0.5 mm²9.211274
IDC 1700-10 4×2×0.54×2×0.5 mm²11.417692
IDC 1700-10 8×2×0.58×2×0.5 mm²14.8295118
IDC 1700-10 12×2×0.512×2×0.5 mm²17.6420141
IDC 1700-10 1×2×1.01×2×1.0 mm²7.68661
IDC 1700-10 2×2×1.02×2×1.0 mm²11.016888
IDC 1700-10 4×2×1.04×2×1.0 mm²13.5264108
IDC 1700-10 8×2×1.08×2×1.0 mm²17.9465143
IDC 1700-10 1×2×1.51×2×1.5 mm²8.511468
IDC 1700-10 4×2×1.54×2×1.5 mm²15.2348122
IDC 1700-10 12×2×1.512×2×1.5 mm²23.4860187
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Additional pair/triad/quad counts (up to 48 pairs) and blue Ex-i intrinsically safe outer sheaths available per UL AWM Style 20130 / CSA.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
Conductor DC resistance & dimensional verification (UL AWM Style 20130 / CSA)DC resistance at 20 °C and geometry within UL AWM Style 20130 / CSA class limitsEvery manufactured drum / spool
Routine dielectric / spark / structural integrity test (UL AWM Style 20130 / CSA)Zero breakdown or structural defect over full production lengthEvery manufactured drum / spool
Sample tests
Thermal aging, mechanical & material qualification (UL AWM Style 20130 / CSA)Full compliance with UL AWM Style 20130 / CSA across −20…+105 °CType qualification & periodic sample audit

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

UL AWM Style 20130 CompliantEN 10204 3.1 Routine Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

TEBAOFLEX IDC 1700-10 <size> UL AWM Style 20130 300 V CE
Delivery form
Non-returnable fumigated wooden drums or precision DIN spools
Standard lengths
500 m · 1000 m · 2000 m drums (custom cut lengths on request)
MOQ
500 m (stock sizes) · 1000 m (custom production)
Lead time
2–4 weeks ex-works
Incoterms
EXW, FCA, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-10-21
Updated
2026-10-21

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What governing standard and construction define IDC 1700-10 (1700-10 Twisted-Pair Flat Ribbon Cable (0.050" Pitch))?
IDC 1700-10 (1700-10 Twisted-Pair Flat Ribbon Cable (0.050" Pitch)) is manufactured in accordance with UL AWM Style 20130 / CSA for 300 V service over -20 °C to +105 °C. Its 2-layer construction comprises stranded tinned copper conductor, pvc core insulation.
What is the minimum bending radius and installation temperature for IDC 1700-10?
The minimum installed bending radius for IDC 1700-10 is 5 × OD across its continuous operating temperature range of -20 °C to +105 °C, ensuring mechanical and dielectric stability without conductor or insulation strain.
How are the concentric layers of IDC 1700-10 arranged from inside to outside?
From inside to outside, the construction sequence is: (01) Stranded tinned copper conductor (High-conductivity tinned copper conductor per UL AWM Style 20130 / CSA); (02) PVC core insulation (Extruded PVC dielectric (individual core / group layer)).
What factory test certificates are supplied with IDC 1700-10?
Every production drum or spool of IDC 1700-10 undergoes routine conductor DC resistance, dimensional and dielectric/integrity testing per UL AWM Style 20130 / CSA, and is delivered with an EN 10204 3.1 factory test certificate.

Request a quote

Get an engineering quote for IDC 1700-10

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

IDC 1700-10 1700-10 Twisted-Pair Flat Ribbon Cable (0.050" Pitch)

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote