Contact
submarine & offshore armoured optical cableITU-T G.972 / HYJQF33Optical (-20 to +70 °C)Polypropylene (PP) Yarn Outer Servin

HYJQF33 4–96F Laser-Welded SS & Copper-Tube Single-Armoured Submarine Optical Trunk CableITU-T G.972 / HYJQF33 — Optical — -20 to +70 °C Subsea & Offshore Cable

HYJQF33 4–96F Laser-Welded SS & Copper-Tube Single-Armoured Submarine Optical Trunk Cable featuring laser-welded ss optical tube (4–96×smf) and polypropylene (pp) yarn outer serving (ITU-T G.972 / HYJQF33, Optical, -20 to +70 °C).

Water-resistant
Ozone, UV & moisture
Oil-resistant
Approved
Order designation
HYJQF33 Submarine FO 4–12F EOM/Sub
Outer Ø ≈
8.2 mm
Net weight ≈
260 kg/km
Tensile rating ≈
48.0 kN
Core / stranding
Laser-welded SS FIMT + Steel/Aramid Armour
All sizes (3)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
Optical
Tested per ITU-T G.972 / HYJQF33
Operating temp.
−20…+70 °C
Continuous subsea & offshore service
Min. bend radius
20 × OD
Winch sheave, chute & seabed routing
Core / conductor
Laser-Welded SS
Hermetic gel-filled stainless-steel tube
Outer protection
Polypropylene (P
Bitumen-impregnated polypropylene yarn o
Standard
ITU-T G.972 / HY
ITU-T G.972 / G.652D / G.654E HYJQF33 Si

Typical values for this cable type, based on ITU-T G.972 / G.652D / G.654E HYJQF33 Single-Armoured Submarine Optical Trunk Specification — confirmed in the datasheet and quotation for your order.

Application fit

Is HYJQF33 Submarine FO right for your machine?

HYJQF33 4–96F Laser-Welded SS & Copper-Tube Single-Armoured Submarine Optical Trunk Cable featuring laser-welded ss optical tube (4–96×smf) and polypropylene (pp) yarn outer serving (ITU-T G.972 / HYJQF33, Optical, -20 to +70 °C).

Fixed installation

Suitable

Laser-welded stainless-steel / copper-tube FIMT or water-blocked loose-tube construction protects ITU-T G.652D / G.654E / OM3/OM4 fibres.

Immersion & wet locations

Suitable

Hermetic metallic optical tube, steel vault and high-density PE/PUR serving withstand up to 8,000 m deep-ocean hydrostatic pressure.

Offshore platform & shipboard deck trays

Suitable

Galvanized steel or bronze wire armour and SHF2-MUD / PUR / PE jacket resist seabed abrasion, fishing-gear impact, oil and drilling mud.

Drilling jumbo & rotary mast feed

Suitable

NEK 606 QFCU and IEEE 1580 S670T executions maintain high-speed optical telemetry across hazardous offshore topside zones.

Energy chain / drag chain

Not suitable

Submarine and armoured offshore optical cable is not intended for indoor factory automation drag chains.

Use Deepwater ROV Optical Tether
Typical machinesUnderwater & Ocean ExplorationSubmarine Telecom & Cabled Ocean ObservatoriesIsland, Coastal & Inter-Platform Subsea Optical LinksOffshore Platform & FPSO Fire-Safe Optical BackbonesTactical Marine & Harsh-Environment Optical Deployment

Construction

Layer by layer

Shown: HYJQF33 Submarine FO (ITU-T G.972 / G.652D / G.654E HYJQF33 Single-Armoured Submarine Optical Trunk Specification) featuring laser-welded ss optical tube (4–96×smf), copper tube & hdpe insulation (hyjqf) and polypropylene (pp) yarn outer serving (4-layer construction).

1234
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1Laser-Welded SS Optical Tube (4–96×SMF)Hermetic gel-filled stainless-steel tube housing single-mode fibers
2Copper Tube & HDPE Insulation (HYJQF)Composite copper conductor tube + high-density polyethylene insulation
3Fine Galvanized Steel Wire Armour (33)Helically served fine round galvanized steel wire armour
4Polypropylene (PP) Yarn Outer ServingBitumen-impregnated polypropylene yarn outer protective serving

HYJQF33 Submarine FO — Standard Subsea & Offshore Execution

Built to ITU-T G.972 / G.652D / G.654E HYJQF33 Single-Armoured Submarine Optical Trunk Specification with laser-welded ss optical tube (4–96×smf) and polypropylene (pp) yarn outer serving

HYJQF33 Submarine FO — Custom Continuous Winch / Reel Length

Available in custom continuous subsea winch, tow or seabed lengths with water-blocked terminations

HYJQF33 Submarine FO — Hydrostatic, Tensile & Routine Certified

Supplied with EN 10204 3.1 routine dielectric, optical OTDR / DC resistance & tensile test report

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on ITU-T G.972 / G.652D / G.654E HYJQF33 Single-Armoured Submarine Optical Trunk Specification. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage / transmission duty
Optical (ITU-T G.972 / G.652D / G.654E HYJQF33 Single-Armoured Submarine Optical Trunk Specification)
Core / conductor construction
Laser-Welded SS Optical Tube (4–96×SMF) — Hermetic gel-filled stainless-steel tube housing single-mode fibers
Primary dielectric / buffering
Copper Tube & HDPE Insulation (HYJQF) — Composite copper conductor tube + high-density polyethylene insulation

Thermal

Continuous operating temperature
−20…+70 °C (subsea & offshore duty)
Hydrostatic & thermal stability
Verified thermal and hydrostatic stability per ITU-T G.972 / G.652D / G.654E HYJQF33 Single-Armoured Submarine Optical Trunk Specification
Storage & transport temperature
−40…+80 °C on export wooden/steel winch reel

Mechanical

Outer protection / armouring
Polypropylene (PP) Yarn Outer Serving — Bitumen-impregnated polypropylene yarn outer protective serving
Minimum bending radius
20 × OD
Armour, strength member & mechanical duty
Fine Galvanized Steel Wire Armour (33) — Helically served fine round galvanized steel wire armour

Resistance

Seawater, hydrostatic & hydrolysis resistance
Engineered for continuous seawater immersion, pressure cycling and hydrolysis resistance per ITU-T G.972 / G.652D / G.654E HYJQF33 Single-Armoured Submarine Optical Trunk Specification
Oil, drilling mud & abrasion resistance
Resistant to marine hydraulic oils, salt mist, winch sheave wear and seabed abrasion per ITU-T G.972 / G.652D / G.654E HYJQF33 Single-Armoured Submarine Optical Trunk Specification
RoHS & REACH compliance
RoHS 2 (2011/65/EU + 2015/863) & REACH SVHC compliant

Reference standards

Governing standard
ITU-T G.972 / G.652D / G.654E HYJQF33 Single-Armoured Submarine Optical Trunk Specification
Environmental & test standards
IEC 60228 / IEC 60794 / ITU-T G.972 / IEEE 1580 / EN 10204
Quality management & inspection
ISO 9001:2015 & EN 10204 3.1 factory routine inspection

Identification

Model designation
HYJQF33 Submarine FO
Sheath colour & metre marking
Continuous metre-marked black outer finish (Polypropylene (P)
Customs tariff (HS)
8544.49 / 8544.60 / 8544.70

Sizes

3 standard HYJQF33 Submarine FO subsea & offshore configurations

Manufactured to ITU-T G.972 / G.652D / G.654E HYJQF33 Single-Armoured Submarine Optical Trunk Specification for subsea, oceanographic, ROV, seismic and offshore applications.

Dimensions, tensile load & weights
Order designationConfigurationCore / strandingOuter Ø ≈
mm
Net weight ≈
kg/km
Breaking / tensile
kN ≈
Min. bend R
mm
Enquiry
HYJQF33 Submarine FO Construction Schedule (−20…+70 °C)
HYJQF33 Submarine FO 4–12F EOM/Sub4–12 × ITU-T G.652D / G.654E SM (+ Power)Laser-welded SS FIMT + Steel/Aramid Armour8.226048.0125
HYJQF33 Submarine FO 24–48F EOM/Sub24–48 × ITU-T G.652D / G.654E SM (+ Power)Laser-welded SS FIMT + Contra-Helical Steel17.5680120.0260
HYJQF33 Submarine FO 96–192F Trunk96–192 × ITU-T G.654E / G.652D SubmarineSS Tube + Steel Vault + Cu Tube + DA Armour28.01,650300.0420
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Custom core cross-sections, pair/fibre counts, armour breaking loads and continuous winch/seabed lengths available per ITU-T G.972 / G.652D / G.654E HYJQF33 Single-Armoured Submarine Optical Trunk Specification.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
Conductor resistance, optical OTDR continuity & dimensional verification (ITU-T G.972 / G.652D / G.654E HYJQF33 Single-Armoured Submarine Optical Trunk Specification)DC resistance at 20 °C / optical attenuation and outer diameter within ITU-T G.972 / G.652D / G.654E HYJQF33 Single-Armoured Submarine Optical Trunk Specification tolerancesEvery manufactured drum length
High-voltage dielectric & insulation resistance test (ITU-T G.972 / G.652D / G.654E HYJQF33 Single-Armoured Submarine Optical Trunk Specification)Zero dielectric breakdown and verified insulation resistance for Optical ratingEvery manufactured drum length
Sample tests
Hydrostatic pressure, tensile breaking load & water-blocking qualification (ITU-T G.972 / G.652D / G.654E HYJQF33 Single-Armoured Submarine Optical Trunk Specification)Verified subsea pressure integrity, torque-balanced tensile performance and thermal stability across −20…+70 °CType qualification & periodic lot audit

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

ITU-T G.972 / HYJQF33 CompliantEN 10204 3.1 Factory Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

TEBAOFLEX HYJQF33 Submarine FO ITU-T G.972 / HYJQF33 Optical CE
Delivery form
Heavy-duty export fumigated wooden drums, steel oceanographic winch reels or submarine turntables
Standard lengths
500 m, 1,000 m, 3,000 m, 6,000 m or custom continuous subsea lengths
MOQ
100 m (standard configurations) · 500 m (custom subsea builds)
Lead time
2–6 weeks ex-works
Incoterms
EXW, FCA, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-10-26
Updated
2026-10-26

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What governing standard and construction define HYJQF33 Submarine FO (HYJQF33 4–96F Laser-Welded SS & Copper-Tube Single-Armoured Submarine Optical Trunk Cable)?
HYJQF33 Submarine FO (HYJQF33 4–96F Laser-Welded SS & Copper-Tube Single-Armoured Submarine Optical Trunk Cable) is manufactured in accordance with ITU-T G.972 / G.652D / G.654E HYJQF33 Single-Armoured Submarine Optical Trunk Specification for Optical service over -20 to +70 °C. Its 4-layer construction comprises laser-welded ss optical tube (4–96×smf), copper tube & hdpe insulation (hyjqf) and polypropylene (pp) yarn outer serving.
What is the minimum bending radius and operating temperature range for HYJQF33 Submarine FO?
The minimum bending radius for HYJQF33 Submarine FO is 20 × OD across its continuous operating temperature range of -20 to +70 °C, ensuring mechanical, hydrostatic and dielectric reliability in subsea and offshore service.
How are the concentric layers of HYJQF33 Submarine FO arranged from inside to outside?
From inside to outside, the construction sequence is: (01) Laser-Welded SS Optical Tube (4–96×SMF) — Hermetic gel-filled stainless-steel tube housing single-mode fibers; (02) Copper Tube & HDPE Insulation (HYJQF) — Composite copper conductor tube + high-density polyethylene insulation; (03) Fine Galvanized Steel Wire Armour (33) — Helically served fine round galvanized steel wire armour; (04) Polypropylene (PP) Yarn Outer Serving — Bitumen-impregnated polypropylene yarn outer protective serving.
What factory test certificates are supplied with HYJQF33 Submarine FO?
Every production drum of HYJQF33 Submarine FO undergoes routine conductor resistance/OTDR continuity, high-voltage dielectric and dimensional testing per ITU-T G.972 / G.652D / G.654E HYJQF33 Single-Armoured Submarine Optical Trunk Specification, and is delivered with an EN 10204 3.1 factory test certificate.

Request a quote

Get an engineering quote for HYJQF33 Submarine FO

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

HYJQF33 Submarine FO HYJQF33 4–96F Laser-Welded SS & Copper-Tube Single-Armoured Submarine Optical Trunk Cable

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp