Fixed installation
High-density multi-core construction routes compactly through marine cable trays, bulkheads and equipment racks.
Product
HF-MPYC, HF-MPYCY, HF-MPYCS & HF-MPYCYS 150/250 V (JIS C 3410) Halogen-Free EPR/XLPE-Insulated Multi-Core Screened & Braided-Armoured SHF1 Shipboard Control Cable (JIS C 3410 / IEC 60092-353, 150/250 V, -40 to +90 °C).
Typical values for this cable type, based on JIS C 3410:2018 & IEC 60092-353 / IEC 60092-376 — confirmed in the datasheet and quotation for your order.
Application fit
HF-MPYC, HF-MPYCY, HF-MPYCS & HF-MPYCYS 150/250 V (JIS C 3410) Halogen-Free EPR/XLPE-Insulated Multi-Core Screened & Braided-Armoured SHF1 Shipboard Control Cable (JIS C 3410 / IEC 60092-353, 150/250 V, -40 to +90 °C).
High-density multi-core construction routes compactly through marine cable trays, bulkheads and equipment racks.
Number-coded or colour-coded cores simplify termination inside marine switchgear, bridge consoles and control panels.
Cross-linked LFH/SHF1/Type P jacket resists marine oils, lubricants, moisture and mechanical abrasion.
High-coverage copper or bronze braid provides both mechanical protection and 360° EMC screening.
Fixed shipboard and naval control cable is not intended for vertical deepwater lift winches.
Use A304739 BOP MUX UmbilicalConstruction
Shown: HF-MPYC / HF-MPYCY & HF-MPYCYS 250 V (JIS C 3410) (JIS C 3410:2018 & IEC 60092-353 / IEC 60092-376) featuring tinned copper control cores (12×1.5 mm²), number-printed hf-epr/xlpe insulation and shf1 zero-halogen outer sheath (hf-...y) (5-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | Tinned Copper Control Cores (12×1.5 mm²) | 12 stranded tinned copper conductors (2 to 60 cores available) |
| 2 | Number-Printed HF-EPR/XLPE Insulation | White halogen-free cross-linked insulation with clear number markings |
| 3 | Copper Tape Electrostatic Screen (S) | Helically lapped copper tape shield on HF-MPYCS / HF-MPYCYS |
| 4 | Galvanized Steel Wire Braid Armour (C) | Braided galvanized steel wire mechanical armour |
| 5 | SHF1 Zero-Halogen Outer Sheath (HF-...Y) | Low-smoke zero-halogen polyolefin outer jacket |
Built to JIS C 3410:2018 & IEC 60092-353 / IEC 60092-376 with tinned copper control cores (12×1.5 mm²) and shf1 zero-halogen outer sheath (hf-...y)
Available in custom continuous shipboard/offshore drum lengths or with marine EMC cable glands
Supplied with EN 10204 3.1 routine dielectric, conductor resistance & flame/fire test report
Technical data
Sizes
Manufactured to JIS C 3410:2018 & IEC 60092-353 / IEC 60092-376 for shipboard, offshore platform, drilling rig and marine applications.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Tensile rating kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| HF-MPYC / HF-MPYCY & HF-MPYCYS 250 V (JIS C 3410) Construction Schedule (−40…+90 °C) | |||||||
| HF-MPYC 4G2.5 mm² | 4 × 2.5 mm² (or 4C × 14 AWG) | IEC 60228 Class 2/5 Cu/SnCu | 13.2 | 275 | 1.5 | 80 | |
| HF-MPYC 7G2.5 mm² | 7 × 2.5 mm² (or 7C × 14 AWG) | IEC 60228 Class 2/5 Cu/SnCu | 15.8 | 415 | 2.6 | 95 | |
| HF-MPYC 12G1.5 mm² | 12 × 1.5 mm² (or 12C × 16 AWG) | IEC 60228 Class 2/5 Cu/SnCu | 17.4 | 495 | 2.7 | 105 | |
| Configuration | Max. DC R₂₀ / Atten. Ω/km or dB/km | Rating / Impedance | Operating temp. |
|---|---|---|---|
| 4 × 2.5 mm² (or 4C × 14 AWG) | 7.98 | 150/250 V (26 A) | −40…+90 °C |
| 7 × 2.5 mm² (or 7C × 14 AWG) | 7.98 | 150/250 V (21 A) | −40…+90 °C |
| 12 × 1.5 mm² (or 12C × 16 AWG) | 13.30 | 150/250 V (14 A) | −40…+90 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance, continuity & dimensional verification (JIS C 3410:2018 & IEC 60092-353 / IEC 60092-376) | DC resistance at 20 °C / optical attenuation and outer diameter within JIS C 3410:2018 & IEC 60092-353 / IEC 60092-376 tolerances | Every manufactured drum length |
| High-voltage dielectric & insulation resistance test (JIS C 3410:2018 & IEC 60092-353 / IEC 60092-376) | Zero dielectric breakdown and verified insulation resistance for 150/250 V rating | Every manufactured drum length |
| Sample tests | ||
| Flame, fire integrity, oil/mud & mechanical qualification (JIS C 3410:2018 & IEC 60092-353 / IEC 60092-376) | Verified flame/fire performance, fluid resistance and thermal stability across −40…+90 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking